《UL 199-2005 UL Standard for Safety Automatic Sprinklers for Fire-Protection Service (Eleventh Edition Reprint with Revisions Through and Including May 12 2017)《防火用自动喷水器》.pdf》由会员分享,可在线阅读,更多相关《UL 199-2005 UL Standard for Safety Automatic Sprinklers for Fire-Protection Service (Eleventh Edition Reprint with Revisions Through and Including May 12 2017)《防火用自动喷水器》.pdf(136页珍藏版)》请在麦多课文档分享上搜索。
1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL UL 199 Automatic Sprinklers for Fire-Protection ServiceUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM ULUL COPYRIGHTED MATERIAL NOT AUTH
2、ORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL UL Standard for Safety for Automatic Sprinklers for Fire-Protection Service UL 199 Eleventh Edition, Dated November 4, 2005 Summary of Topics This revision of ANSI/UL 199 is being issued to include the following changes in re
3、quirements: Revisions to More Closely Align Text with NFPA 13 and Other Sprinkler Standards, Clarify Requirements And Update Testing Details New Air Bath Test for Glass Bulb Sprinklers New Heat Resistance Test Protection of Glass Bulb Tips Control Mode Specic Application (CMSA) Sprinklers Text that
4、has been changed in any manner or impacted by ULs electronic publishing system is marked with a vertical line in the margin. Changes in requirements are marked with a vertical line in the margin and are followed by an effective date note indicating the date of publication or the date on which the ch
5、anged requirement becomes effective. The new requirements are substantially in accordance with Proposal(s) on this subject dated November 30, 2012. All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form by any means, electronic, m
6、echanical photocopying, recording, or otherwise without prior permission of UL. UL provides this Standard as is without warranty of any kind, either expressed or implied, including but not limited to, the implied warranties of merchantability or tness for any purpose. In no event will UL be liable f
7、or any special, incidental, consequential, indirect or similar damages, including loss of prots, lost savings, loss of data, or any other damages arising out of the use of or the inability to use this Standard, even if UL or an authorized UL representative has been advised of the possibility of such
8、 damage. In no event shall ULs liability for any damage ever exceed the price paid for this Standard, regardless of the form of the claim. Users of the electronic versions of ULs Standards for Safety agree to defend, indemnify, and hold UL harmless from and against any loss, expense, liability, dama
9、ge, claim, or judgment (including reasonable attorneys fees) resulting from any error or deviation introduced while purchaser is storing an electronic Standard on the purchasers computer system. The requirements in this Standard are now in effect, except for those paragraphs, sections, tables, gures
10、, and/or other elements of the Standard having future effective dates as indicated in the note following the affected item. The prior text for requirements that have been revised and that have a future effective date are located after the Standard, and are preceded by a SUPERSEDED REQUIREMENTS notic
11、e. The following table lists the future effective dates with the corresponding reference. FEBRUARY 20, 2013 UL 199 tr1UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL Future Effective Dates References February 20, 2015 Paragraphs 7.7, 20.2, 2
12、8.1, 36A.1,36A.2,and 67.1.1 FEBRUARY 20, 2013 UL 199 tr2UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL NOVEMBER 4, 2005 (Title Page Reprinted: February 20, 2013) 1 UL 199 Standard for Automatic Sprinklers for Fire-Protection Service First E
13、dition December, 1919 Second Edition February, 1966 Third Edition December, 1967 Fourth Edition October, 1969 Fifth Edition May, 1974 Sixth Edition September, 1977 Seventh Edition July, 1982 Eighth Edition February, 1990 Ninth Edition December, 1995 Tenth Edition April, 1997 Eleventh Edition Novembe
14、r 4, 2005 This ANSI/UL Standard for Safety consists of the Eleventh Edition including revisions through February 20, 2013. The most recent designation of ANSI/UL 199 as an American National Standard (ANSI) occurred on February 19, 2013. The ANSI approval for this standard does not include the Cover
15、Page, Transmittal Pages, Title Page or effective date information. Comments or proposals for revisions on any part of the Standard may be submitted to UL at any time. Proposals should be submitted via a Proposal Request in ULs On-Line Collaborative Standards Development System (CSDS) at http:/. ULs
16、Standards for Safety are copyrighted by UL. Neither a printed nor electronic copy of a Standard should be altered in any way. All of ULs Standards and all copyrights, ownerships, and rights regarding those Standards shall remain the sole and exclusive property of UL. COPYRIGHT 2013 UNDERWRITERS LABO
17、RATORIES INC. ANSI/UL 199-2013UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL FEBRUARY 20, 2013 AUTOMATIC SPRINKLERS FOR FIRE-PROTECTION SERVICE - UL 199 2 No Text on This PageUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION O
18、R DISTRIBUTION WITHOUT PERMISSION FROM UL CONTENTS INTRODUCTION 1 Scope .7 2 Components 7 3 Units of Measurements 7 4 Undated References 8 5 Glossary .8 6 Terminology .10A CONSTRUCTION 7 General .10B 8 Inlet Threads 12 9 Temperature Ratings .12 10 Pressure Rating 13 11 Nominal “K” Factor 13 12 Coati
19、ngs And Platings .14 13 Protective Covers .14 PERFORMANCE GENERAL 14 Details .14 15 Samples .19 PHYSICAL STRENGTH AND LEAKAGE TESTS 16 Load on Heat Responsive Element Test .19 17 Strength Of Heat Responsive Element Test 19 17.1 Fusible-alloy types 19 17.2 Glass-bulb types .20 18 Glass-bulb Thermal S
20、hock Test 20 19 Strength Of Frame Test .21 20 Impact Resistance Test 21 21 Impact Test for Protective Covers .23 22 Rough Usage Test 25 23 Flow Endurance Test 25 24 Leakage Test 26 25 Hydrostatic Strength Test 26 26 Dry Sprinkler Air Tightness Test 26 27 30-Day Leakage Test .28 28 Water Hammer Test
21、29 29 Vacuum Test .30 FEBRUARY 20, 2013 AUTOMATIC SPRINKLERS FOR FIRE-PROTECTION SERVICE - UL 199 3UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL OPERATION TESTS 30 Operating Temperature (Bath) Test .30 30A Air Bath Test for Glass Bulb Spri
22、nklers .30A 31 Sensitivity Tests .30A 31.1 General 30A 31.2 Oven heat test 30B 31.3 Room heat test for ordinary and intermediate temperature rated standard response ceiling type sprinklers (including concealed, ush, and recessed) 36 31.4 Room heat test for standard response extended coverage sprinkl
23、ers .40 31.5 Room heat test for QR and QR extended coverage sprinklers 40B 32 Operation Lodgement Test 40F 33 Cycling Tests For Flow Control (FC) Sprinklers 40I 33.1 Operational cycling test .40I 33.2 Cycling after water exposure test 40I 33.3 Contaminated-water cycling test .40I EXPOSURE AND CORROS
24、ION TESTS 34 High Temperature Exposure Test (90 Day) .40J 35 High Temperature Exposure Test For Wax Coated Sprinklers 41 36 High Temperature Exposure Test For Flow Control (FC) Sprinklers .41 36A Heat Resistance Test .41 37 Elastomeric Parts Test 42 38 Vibration Test 42 39 Freezing Test 43 40 Evapor
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- UL1992005ULSTANDARDFORSAFETYAUTOMATICSPRINKLERSFORFIREPROTECTIONSERVICEELEVENTHEDITIONREPRINTWITHREVISIONSTHROUGHANDINCLUDINGMAY122017

链接地址:http://www.mydoc123.com/p-1067739.html