SANS 53121-3-2009 GRP tanks and vessels for use above ground Part 3 Design and workmanship《地面使用的玻璃钢容器 第3部分 设计及工艺》.pdf
《SANS 53121-3-2009 GRP tanks and vessels for use above ground Part 3 Design and workmanship《地面使用的玻璃钢容器 第3部分 设计及工艺》.pdf》由会员分享,可在线阅读,更多相关《SANS 53121-3-2009 GRP tanks and vessels for use above ground Part 3 Design and workmanship《地面使用的玻璃钢容器 第3部分 设计及工艺》.pdf(238页珍藏版)》请在麦多课文档分享上搜索。
1、 Collection of SANS standards in electronic format (PDF) 1. Copyright This standard is available to staff members of companies that have subscribed to the complete collection of SANS standards in accordance with a formal copyright agreement. This document may reside on a CENTRAL FILE SERVER or INTRA
2、NET SYSTEM only. Unless specific permission has been granted, this document MAY NOT be sent or given to staff members from other companies or organizations. Doing so would constitute a VIOLATION of SABS copyright rules. 2. Indemnity The South African Bureau of Standards accepts no liability for any
3、damage whatsoever than may result from the use of this material or the information contain therein, irrespective of the cause and quantum thereof. ISBN 978-0-626-22249-9 SANS 53121-3:2009Edition 1EN 13121-3:2008Edition 1SOUTH AFRICAN NATIONAL STANDARD GRP tanks and vessels for use above ground Part
4、3: Design and workmanship This national standard is the identical implementation of EN 13121-3:2008 and is adopted with the permission of CEN, rue de Stassart 36, B-1050 Brussels. Published by SABS Standards Division 1 Dr Lategan Road Groenkloof Private Bag X191 Pretoria 0001Tel: +27 12 428 7911 Fax
5、: +27 12 344 1568 www.sabs.co.za SABS SANS 53121-3:2009 Edition 1 EN 13121-3:2008 Edition 1 Table of changes Change No. Date Scope National foreword This South African standard was approved by National Committee SABS TC 1015, Fibre-reinforced plastics products, in accordance with procedures of the S
6、ABS Standards Division, in compliance with annex 3 of the WTO/TBT agreement. This SANS document was published in July 2009. EUROPEAN STANDARDNORME EUROPENNEEUROPISCHE NORMEN 13121-3June 2008ICS 23.020.10English VersionGRP tanks and vessels for use above ground - Part 3: Designand workmanshipRservoir
7、s et rcipients en PRV pour applications hors sol -Partie 3: Conception et fabricationOberirdische GFK-Tanks und -Behlter - Teil 3: Auslegungund HerstellungThis European Standard was approved by CEN on 21 April 2008.CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipu
8、late the conditions for giving this EuropeanStandard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such nationalstandards may be obtained on application to the CEN Management Centre or to any CEN member.This European Standard exi
9、sts in three official versions (English, French, German). A version in any other language made by translationunder the responsibility of a CEN member into its own language and notified to the CEN Management Centre has the same status as theofficial versions.CEN members are the national standards bod
10、ies of Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland,France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal,Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom.EUROP
11、EAN COMMITTEE FOR STANDARDIZATIONCOMIT EUROPEN DE NORMALISATIONEUROPISCHES KOMITEE FR NORMUNGManagement Centre: rue de Stassart, 36 B-1050 Brussels 2008 CEN All rights of exploitation in any form and by any means reservedworldwide for CEN national Members.Ref. No. EN 13121-3:2008: EEN 13121-3:2008 (
12、E) 2 Contents Page Foreword6 Introduction .7 1 Scope 8 2 Normative references 8 3 Terms and definitions .10 4 Symbols and abbreviations 11 5 Information and requirements to be supplied and to be documented.14 5.1 General14 5.2 Information to be obtained by the manufacturer14 5.3 Information to be pr
13、epared by the manufacturer .14 5.4 Final documentation15 6 Material .15 6.1 General15 6.2 Chemical protective barrier 15 6.3 Flammability.16 6.4 Electrical resistivity .16 7 Mechanical properties.17 7.1 General17 7.2 Heat deflection temperature .17 7.3 Laminate construction 17 7.4 Lamina thickness.1
14、9 7.5 Laminate properties 19 7.6 Inter-laminar shear strength.19 7.7 Peel strength 20 7.8 Selection of physical properties of materials and allowable design factors 20 8 Determination of design strain and loadings .25 8.1 General25 8.2 Allowable design strains.25 8.3 Laminate design loadings.26 8.4
15、Laminate design.26 8.5 Laminate thickness27 9 Design .28 9.1 Introduction 28 9.2 Determination of external loads.29 9.3 Drawings and design calculations.30 9.4 Design details.30 10 Design analysis31 10.1 Symbols and units.31 10.2 Vertical vessels or tanks, cylinders under loads (t 60 C (HDT 40 C) TS
16、 7.3 Laminate construction The final external surface of the tank or vessel which shall be a minimum of 450 g/m2CSM or continuous filament windings construction, shall be finished with a surface veil. EN 13121-3:2008 (E) 18 Table 3 Minimum properties of laminate layers Type of reinforcement Directio
17、n Applicable criteria UTUS UiN/mm per kg/m2glassUnit tensile modulus XiN/mm per kg/m2glassShear strength N/mm Shear modulus G N/mm CSM All 200 14 000 All 140 14 000 CSM (furane/ phenolic) WR Warp 61 500 x 4 000+24 000 x 65 60 4 000 Warp 61 320 x 4 000+24 000 x 65 40 4 000 FW 85 1,0 and 1,4. 7.8.4.6
18、Derivation of partial design factor A4A4is the partial design factor relating to the expected number of operation cycles, where cycles relate to pressure or temperature or temperature and pressure. For the design strain levels allowed in this standard, the factor shall be 1,0. 7.8.4.7 Derivation of
19、partial design factor A5A5is the partial design factor relating to long term performance of the laminate and shall be determined either by reference to Table 5 or by testing in accordance with D.16. In the absence of test data, A5shall be taken from Table 5. Table 5 The value of partial design facto
20、r A5 Short term A5Tension A5Flexural Loading Life of tank or vessel Life of tank or vessel Reinforcement-resin system Polyester- and Vinylester up to 30 min up to 10 yearsup to 50 years up to 10 years up to 50 years WR 1,0 1,25 1,30 1,50 1,90 CSM 1,0 2,00 2,40 2,00 2,40 FW circumferential 1,0 1,20 1
21、,30 1,30 1,40 FW axial 1,0 1,50 1,60 1,60 1,70 Where combination laminates of CSM/WR/FW are to be used, the value of A5shall be taken for the major constituent. For intermediate lifetimes between 10 and 50 years, values of A5may be determined by linear interpolation. When the value of A5is to be det
22、ermined by testing of the laminate, the test to be carried out shall be in accordance with test D.16. EN 13121-3:2008 (E) 24 An early assessment of the partial design factor A5can be determined using the short term creep test (see method D.10), but the final value used in the design shall be that de
23、termined from the long term creep test (see method D.16). The partial design factor A5shall not be less than 1,20, other than for short term loads (see Table 5). For the calculation of the buckling Factor F (see 7.8.4), only the A5value for Flexural shall be used. For the calculation of the overall
24、design Factor K (see 7.8.4) the A5value depends upon the applied load under consideration. Where the loading is a combination of both Tension and Flexural, the A5value for Tension shall be used. The different A5factors for different types of load, may result in a range of K and F factors (see 7.8.4)
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- SANS5312132009GRPTANKSANDVESSELSFORUSEABOVEGROUNDPART3DESIGNANDWORKMANSHIP 地面 使用 玻璃钢 容器 部分 设计 工艺 PDF

链接地址:http://www.mydoc123.com/p-1030871.html