SANS 1670-2008 Warning lights《警报灯》.pdf
《SANS 1670-2008 Warning lights《警报灯》.pdf》由会员分享,可在线阅读,更多相关《SANS 1670-2008 Warning lights《警报灯》.pdf(17页珍藏版)》请在麦多课文档分享上搜索。
1、 Collection of SANS standards in electronic format (PDF) 1. Copyright This standard is available to staff members of companies that have subscribed to the complete collection of SANS standards in accordance with a formal copyright agreement. This document may reside on a CENTRAL FILE SERVER or INTRA
2、NET SYSTEM only. Unless specific permission has been granted, this document MAY NOT be sent or given to staff members from other companies or organizations. Doing so would constitute a VIOLATION of SABS copyright rules. 2. Indemnity The South African Bureau of Standards accepts no liability for any
3、damage whatsoever than may result from the use of this material or the information contain therein, irrespective of the cause and quantum thereof. ISBN 978-0-626-21018-2 SANS 1670:2008Edition 1.1Any reference to SABS 1670 is deemedto be a reference to this standard(Government Notice No. 1373 of 8 No
4、vember 2002)SOUTH AFRICAN NATIONAL STANDARD Warning lights Published by Standards South Africa 1 dr lategan road groenkloof private bag x191 pretoria 0001 tel: 012 428 7911 fax: 012 344 1568 international code +27 12 www.stansa.co.za Standards South Africa SANS 1670:2008 Edition 1.1 Table of changes
5、 Change No. Date Scope Amdt 1 2008 Amended to change the designation from SABS to SANS, to update referenced standards, to update the definition for “acceptable”, and to change the requirements for colour and chromaticity co-ordinates (4.2) and flash rate and “on” time (4.4). Foreword This South Afr
6、ican standard was approved by National Committee StanSA TC 5120.71, Lighting and optics for traffic and transport, in accordance with procedures of Standards South Africa, in compliance with annex 3 of the WTO/TBT agreement. This document was published in May 2008. This document supersedes SABS 1670
7、:1996 (edition 1). A vertical line in the margin shows where the text has been technically modified by amendment No. 1. Annexes A and B form an integral part of this document. Annex C is for information only. SANS 1670:2008 Edition 1.1 1 Contents Page Foreword 1 Scope . 3 2 Normative references. 3 3
8、 Definitions 4 4 Requirements. 6 5 Inspection and methods of test 8 5.1 Inspection 8 5.2 General conditions of testing. 8 5.3 Colour test. 9 5.4 Luminous intensity test 9 5.5 Flash rate and “on“ time 9 5.6 Endurance test 10 5.7 Resistance to extreme temperatures 10 5.8 Holding force of temporary lig
9、hts 10 5.9 Vibration and drop test 10 5.10 Impact test. 10 5.11 Radiation test 10 6 Marking 11 Annex A (normative) Notes to purchasers 13 Annex B (normative) Quality verification of warning lights 13 Annex C (informative) Bibliography. 14 SANS 1670:2008 Edition 1.1 2 This page is intentionally left
10、blank SANS 1670:2008 Edition 1.1 3 Warning lights 1 Scope 1.1 This standard specifies the requirements for warning lights for temporary and for permanent mounting on vehicles. 1.2 This standard does not cover a) hazard lights of vehicles (simultaneous operation of all direction indicators); b) the p
11、ositioning of warning lights on a vehicle; and c) the method of connection of warning lights to the vehicles electrical system. 2 Normative references The following standards contain provisions which, through reference in this text, constitute provisions of this standard. All standards are subject t
12、o revision and, since any reference to a standard is deemed to be a reference to the latest edition of that standard, parties to agreements based on this standard are encouraged to take steps to ensure the use of the most recent editions of the standards indicated below. Information on currently val
13、id national and international standards can be obtained from Standards South Africa. IEC 60068-2-32, Basic environmental testing procedures Part 2: Tests Section 32: Test Ed: Free fall. IEC 60068-2-75, Environmental testing Part 2-75:Tests Test Eh: Hammer tests. Amdt 1 IEC 60721-3-5, Classification
14、of environmental conditions Part 3: Classification of groups of environmental parameters and their severities Section 5: Ground vehicle installations. SANS 214-1/CISPR 14-1, Electromagnetic compatibility Requirements for household appliances, electric tools and similar apparatus Part 1: Emission. Am
15、dt 1 SANS 1376-1, Lights for motor vehicles Part 1: Incandescent lamps. SANS 60529/IEC 60529, Degrees of protection provided by enclosures (IP Code). SANS 1670:2008 Edition 1.1 4 3 Definitions For the purposes of this standard, the following definitions apply: 3.1 acceptable acceptable to the author
16、ity administering the standard, or to the parties concluding the purchase contract, as relevant Amdt 1 3.2 colour colour of the light emitted by a warning light, defined in terms of its chromaticity co-ordinates, using the trichromatic system recommended by the International Commission on Illuminati
17、on (CIE) 3.3 effective luminous intensity luminous intensity of the light as determined by the maximum luminous intensity of the flash, the duration of the flash and the shape of the luminous intensity curve of the flash The effective luminous intensity (Je, in candelas) is given numerically by: Je=
18、 TFCJ+1mwhere Jm is the peak intensity, in candelas; C is a time constant (C = 0,2 s); T is the duration of one cycle; F is the form-factor TJdtJmTO; where J is the instantaneous intensity, in candelas. 3.4 flash rate number of times per second that a warning light completes a cycle from maximum lum
19、inous intensity to the next corresponding maximum luminous intensity 3.5 luminous intensity intensity of the light emitted by a warning light in a specific direction NOTE The luminous intensity is expressed in candelas (cd). 3.6 measuring directions directions that are perpendicular to the reference
20、 axis of the light, and that pass through the reference centre of the light SANS 1670:2008 Edition 1.1 5 3.7 “on time“ tH period of time within which the luminous intensity of a flashing light is more than 10 % of the maximum value (peak value) Jmax3.8 power supply voltage range range of primary pow
21、er supply voltage over which a warning light will operate within specified performance parameters 3.9 reference axis of a warning light axis that passes through the reference centre of the light NOTE The reference axis is vertical for a warning light that emits light horizontally through an angle of
22、 360, but horizontal for a warning light that is mounted on the front of a vehicle like a headlight. 3.10 reference centre of a warning light centre of the light-emitting source 3.11 temperature range range of temperatures within which a warning light will operate within specified performance parame
23、ters 3.12 type of warning light type of the warning light as determined by: a) the trade name or make; b) the size and form of the coloured cover; c) the optical system; d) the nature of the beam (rotating or stationary flashing); e) the colour of the light emitted; f) the light source; and g) wheth
24、er the light has one or two levels of luminous intensity 3.13 vibration stability ability of a warning light to operate within specified mechanical and electrical performance parameters after a mechanical vibration test 3.14 warning light light that emits light intermittently around its reference ax
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- SANS16702008WARNINGLIGHTS 警报 PDF