SAE AMS 3653F-2016 Tubing Electrical Insulation Standard Wall Extruded Polytetrafluoroethylene (PTFE).pdf
《SAE AMS 3653F-2016 Tubing Electrical Insulation Standard Wall Extruded Polytetrafluoroethylene (PTFE).pdf》由会员分享,可在线阅读,更多相关《SAE AMS 3653F-2016 Tubing Electrical Insulation Standard Wall Extruded Polytetrafluoroethylene (PTFE).pdf(8页珍藏版)》请在麦多课文档分享上搜索。
1、_ SAE Technical Standards Board Rules provide that: “This report is published by SAE to advance the state of technical and engineering sciences. The use of this report is entirely voluntary, and its applicability and suitability for any particular use, including any patent infringement arising there
2、from, is the sole responsibility of the user.” SAE reviews each technical report at least every five years at which time it may be revised, reaffirmed, stabilized, or cancelled. SAE invites your written comments and suggestions. Copyright 2016 SAE International All rights reserved. No part of this p
3、ublication may be reproduced, stored in a retrieval system or transmitted, in any form or by any means, electronic, mechanical, photocopying, recording, or otherwise, without the prior written permission of SAE. TO PLACE A DOCUMENT ORDER: Tel: 877-606-7323 (inside USA and Canada) Tel: +1 724-776-497
4、0 (outside USA) Fax: 724-776-0790 Email: CustomerServicesae.org SAE WEB ADDRESS: http:/www.sae.org SAE values your input. To provide feedback on this Technical Report, please visit http:/www.sae.org/technical/standards/AMS3653F AEROSPACE MATERIAL SPECIFICATION AMS3653 REV. F Issued 1957-01 Reaffirme
5、d 1999-01 Revised 2016-09 Superseding AMS3653E Tubing, Electrical Insulation Standard Wall, Extruded Polytetrafluoroethylene (PTFE) RATIONALE Minor changes are a result of 5 year review. 1. SCOPE 1.1 Form This specification covers extruded polytetrafluoroethylene (PTFE) in the form of flexible tubin
6、g. 1.2 Application This tubing has been used typically as electrical insulating sheath up to 260 C (500 F), but usage is not limited to such applications. 1.3 Safety - Hazardous Materials While the materials, methods, applications, and processes described or referenced in this specification may invo
7、lve the use of hazardous materials, this specification does not address the hazards which may be involved in such use. It is the sole responsibility of the user to ensure familiarity with the safe and proper use of any hazardous materials and to take necessary precautionary measures to ensure the he
8、alth and safety of all personnel involved. 2. APPLICABLE DOCUMENTS The issue of the following documents in effect on the date of the purchase order forms a part of this specification to the extent specified herein. The supplier may work to a subsequent revision of a document unless a specific docume
9、nt issue is specified. When the referenced document has been cancelled and no superseding document has been specified, the last published issue of that document shall apply. SAE INTERNATIONAL AMS3653F Page 2 of 8 2.1 ASTM Publications Available from ASTM International, 100 Barr Harbor Drive, P.O. Bo
10、x C700, West Conshohocken, PA 19428-2959, Tel: 610-832-9585, www.astm.org. ASTM D876 Testing Nonrigid Vinyl Chloride Polymer Tubing Used for Electrical Insulation ASTM D1675 Testing Polytetrafluoroethylene Tubing 2.2 U.S. Government Publications Copies of these documents are available online at http
11、:/quicksearch.dla.mil. MIL-STD-104 Limit for Electrical Insulation Color MIL-STD-2073-1 Standard Practice for Military Packaging 3. TECHNICAL REQUIREMENTS 3.1 Material Shall be flexible tubing made from extruded polytetrafluoroethylene (PTFE). 3.2 Color Shall be natural, ranging from colorless trans
12、lucent to semi-opaque white. When ordered in colors, the colors shall be in accordance with MIL-STD-104 or as agreed upon by purchaser and vendor. 3.3 Properties Tubing shall conform to the requirements shown in Table 1; tests shall be performed on the tubing supplied and in accordance with specifie
13、d ASTM methods, insofar as practicable: SAE INTERNATIONAL AMS3653F Page 3 of 8 Table 1 - Properties Paragraph Property Requirement Test Method 3.3.1 Tensile Strength at 200% Elongation 2500 to 6000 psi (17.2 to 41.4 MPa) ASTM D876 73.4 F 3.6 F (23 C 2 C) 3.3.2 Elongation, minimum 200% ASTM D876 73.4
14、 F 3.6 F (23 C 2 C) 3.3.3 Dielectric Breakdown Voltage, minimum average Nominal Nominal Wall Thickness Wall Thickness Inch Millimeters 0.009 0.23 0.012 0.30 0.016 0.41 0.020 0.51 0.025 0.64 0.030 0.76 0.035 0.89 0.040 1.02 8000 volts 10 000 volts 13 000 volts 16 000 volts 18 000 volts 20 000 volts 2
15、0 000 volts 20 000 volts ASTM D876 73.4 F 3.6 F (23 C 2 C) 3.3.4 Specific Gravity 2.14 - 2.21 ASTM D1675 3.3.5 Strain Relief (shrinkage), maximum 1.0% ASTM D1675 572 F 5 F (300 C 3 C) 3.3.6 Volatile Loss, maximum 0.05% ASTM D1675 572 F 5 F (300 C 3 C) 3.4 Quality Tubing, as received by purchaser, sh
16、all be uniform in quality and condition, smooth, and free from foreign materials and from imperfections detrimental to usage of the tubing. 3.5 Sizes and Tolerances Shall be as shown in Table 2; tolerances apply at 68 to 86 F (20 to 30 C), measured in accordance with ASTM D1675. 4. QUALITY ASSURANCE
17、 PROVISIONS 4.1 Responsibility for Inspection The vendor of tubing shall supply all samples for vendors tests and shall be responsible for performing all required tests. Purchaser reserves the right to sample and to perform any confirmatory testing deemed necessary to ensure that the tubing conforms
18、 to the requirements of this specification. SAE INTERNATIONAL AMS3653F Page 4 of 8 Table 2A - Sizes and tolerances, inch/pound units Size No. ID, Inches Nominal ID, Inches Minimum ID, Inches Maximum Wall Thickness Inch Nominal Wall Thickness Tolerance Inch 30 0.012 0.010 0.015 0.009 0.002 28 0.015 0
19、.013 0.019 0.009 0.002 26 0.018 0.016 0.022 0.009 0.002 24 0.022 0.020 0.027 0.012 0.003 23 0.026 0.023 0.030 0.012 0.003 22 0.028 0.025 0.032 0.012 0.003 21 0.032 0.029 0.036 0.012 0.003 20 0.034 0.032 0.040 0.016 0.003 19 0.038 0.036 0.044 0.016 0.003 18 0.042 0.040 0.049 0.016 0.003 17 0.047 0.04
20、5 0.054 0.016 0.003 16 0.053 0.051 0.061 0.016 0.003 15 0.059 0.057 0.067 0.016 0.003 14 0.066 0.064 0.074 0.016 0.003 13 0.076 0.072 0.082 0.016 0.003 12 0.085 0.081 0.091 0.016 0.003 11 0.095 0.091 0.101 0.016 0.003 10 0.106 0.102 0.112 0.016 0.003 9 0.118 0.114 0.124 0.020 0.004 1/8 0.125 0.120 0
21、.130 0.020 0.004 8 0.133 0.129 0.141 0.020 0.004 7 0.148 0.144 0.158 0.020 0.004 6 0.166 0.162 0.178 0.020 0.004 5 0.186 0.182 0.198 0.020 0.004 4 0.208 0.204 0.224 0.020 0.004 3 0.234 0.229 0.249 0.020 0.004 1/4 0.255 0.250 0.260 0.020 0.004 2 0.263 0.258 0.278 0.020 0.004 1 0.294 0.289 0.311 0.020
22、 0.004 5/16 0.321 0.313 0.334 0.020 0.004 0 0.330 0.325 0.347 0.020 0.004 3/8 0.387 0.375 0.399 0.025 0.005 7/16 0.451 0.438 0.464 0.025 0.005 1/2 0.515 0.500 0.530 0.025 0.005 5/8 0.643 0.625 0.662 0.025 0.005 3/4 0.772 0.750 0.795 0.030 0.006 7/8 0.901 0.875 0.927 0.035 0.007 1 1.030 1.000 1.060 0
23、.035 0.007 1-1/4 1.287 1.250 1.325 0.040 0.007 SAE INTERNATIONAL AMS3653F Page 5 of 8 Table 2B - Sizes and tolerances, SI units Size No. ID Millimeters Nominal ID Millimeters Minimum ID Millimeters Maximum Wall Thickness Millimeters Nominal Wall Thickness Tolerance Millimeter 30 0.30 0.25 0.38 0.23
24、0.05 28 0.38 0.33 0.48 0.23 0.05 26 0.46 0.41 0.56 0.23 0.05 24 0.56 0.51 0.68 0.30 0.08 23 0.66 0.58 0.76 0.30 0.08 22 0.71 0.64 0.81 0.30 0.08 21 0.81 0.74 0.91 0.30 0.08 20 0.86 0.81 1.02 0.41 0.08 19 0.96 0.91 1.12 0.41 0.08 18 1.07 1.02 1.24 0.41 0.08 17 1.19 1.14 1.37 0.41 0.08 16 1.35 1.30 1.
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- SAEAMS3653F2016TUBINGELECTRICALINSULATIONSTANDARDWALLEXTRUDEDPOLYTETRAFLUOROETHYLENEPTFEPDF

链接地址:http://www.mydoc123.com/p-1021038.html