1、Lessons Learned Entry: 1380Lesson Info:a71 Lesson Number: 1380a71 Lesson Date: 2003-01-01a71 Submitting Organization: WSTFa71 Submitted by: Michael J. Hallock, IISubject: Druck Pressure Transducer, Model No. PDCR 130/W/C, Failure Abstract: On March 25, 2003, during life cycle testing of the Improved
2、 Pilot Operating Valve (IPOV) in Nitrogen Tetroxide (NTO), a pressure transducer catastrophically failed in an explosion and released NTO into the test cell. Reference Government-Industry Data Exchange Program (GIDEP): DOC=QB-S-03-01 CEDATE=30-MAY-2003 DD=SA,Title: PRESSURE TRANSDUCER, SILICONE OIL
3、FILLED. Description of Driving Event: The pressure transducer was located at the inlet of the IPOV and experienced dynamic pressure fluctuations as the IPOV opened and closed for each 80 microsecond flow duration. The investigation included review of test data, analysis of the failed hardware, inves
4、tigation into the design and construction of the transducer, review of historical data on it, chemical analysis of residue in the area of the failure, and comparison of this residue with the products of silicone oil exposed to NTO in a “beaker test.” The item was purchased in 1994 and was used in a
5、helium system and then in an oxidizer system. The pressure transducer failed at a welded connection between the port housing and the sensor housing. The pressure required to fail this welded connection was calculated to be 12,700 pounds per square inch (psi). The pressure transducer is connected by
6、a ? X 0.035 wall 300 series stainless steel tubing to ? X 0.035 inch wall 300 series stainless steel tubing. The thrust from the failed pressure transducer resulted in also failing the ? inch tubing close to the ? inch tubing. The ? inch tubing showed no sign of yielding due to pressure, indicating
7、that the system pressure did not exceed the calculated 3,400 psi required to yield this tubing. Failure appears to be the result of extremely rapid over pressurization inside the pressure transducer. The pressure transducer has a silicon sensor and a 316 stainless steel isolation diaphragm between t
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- REGNASALLIS13802003LESSONSLEARNEDDRUCKPRESSURETRANSDUCERMODELNOPDCR130WCFAILUREPDF

链接地址:http://www.mydoc123.com/p-1019019.html