NFPA 20 ERTA 1-2016 en Standard for the Installation of Stationary Pumps for Fire Protection.pdf
《NFPA 20 ERTA 1-2016 en Standard for the Installation of Stationary Pumps for Fire Protection.pdf》由会员分享,可在线阅读,更多相关《NFPA 20 ERTA 1-2016 en Standard for the Installation of Stationary Pumps for Fire Protection.pdf(2页珍藏版)》请在麦多课文档分享上搜索。
1、 Errata NFPA 20 Standard for the Installation of Stationary Pumps for Fire Protection 2016 Edition Reference: Various Errata No: 20-16-1 The Committee on Fire Pumps notes the following errors in the 2016 edition of NFPA 20, Standard for the Installation of Stationary Pumps for Fire Protection. 1. Ch
2、ange the cross reference in 4.20.2.2(4) to read as follows: 4.20.2.2(4) The interconnect control wiring between the controllers in different pump rooms shall comply with 4.20.2.78 and 4.20.2.89. 2. Change the cross references in 4.20.2.9.1.2(1) and (3) to read as follows: 4.20.2.9.1.2(1) Pump runnin
3、g in accordance with 12.4.2.3(1) 4.20.2.9.1.2(3) Trouble on controller or engine in accordance with 12.4.2.3(3) 3. Change the cross reference in 8.1.1 to read as follows: 8.1.1 Types. Positive displacement pumps shall be as defined in 3.3.3844.14. 4. Change the cross reference in 10.5.2.1.3.1* and d
4、elete two commas to read as follows: 10.5.2.1.3.1* Where the transducer pressure reading exceeds 10 psi (0.68 bar) during any automatic pump start that was initiated by the solenoid drain valve, as required by 10.5.2.1.87.3, the controller shall activate a visual and audible, alarm that can be silen
5、ced. 5. Change the cross reference in 11.2.2.6 to read as follows: 11.2.2.6 Where right-angle gear drives (see 11.2.3.27.5.1.8) are used between the vertical turbine pump and its driver, the horsepower requirement of the pump shall be increased to allow for power loss in the gear drive. 6. Change th
6、e cross reference in 11.2.8.5.3.8(A)* to read as follows: 11.2.8.5.3.8(A)* The spring-loaded check valve(s) shall replace the second indicating manual shutoff valve(s) in the cooling loop assembly as stated in 11.2.8.5.3.43. 7. Change the cross reference in 11.4.1.5.6.1 to read as follows: 11.4.1.5.
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- NFPA20ERTA12016ENSTANDARDFORTHEINSTALLATIONOFSTATIONARYPUMPSFORFIREPROTECTIONPDF

链接地址:http://www.mydoc123.com/p-1008457.html