NAVY MS3370 REV B-1991 CONVERTER 100 AMPERE CLASS C NONREGULATED AIRCRAFT BLAST COOLED《鼓风冷却型非管制航空器C类100安培换流器》.pdf
《NAVY MS3370 REV B-1991 CONVERTER 100 AMPERE CLASS C NONREGULATED AIRCRAFT BLAST COOLED《鼓风冷却型非管制航空器C类100安培换流器》.pdf》由会员分享,可在线阅读,更多相关《NAVY MS3370 REV B-1991 CONVERTER 100 AMPERE CLASS C NONREGULATED AIRCRAFT BLAST COOLED《鼓风冷却型非管制航空器C类100安培换流器》.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、I MS3370-1 1 I WERTER. 100 AMPERE MILITARY STANDARD ZEGULATED Dther Cust I AIRCRAFT, BLAST COOLED ARMY MS3370 Procurement Specifications SEET lop5 MIL-C-7115 DD 672 (COORDINATED) PAMOUSEDITKINSOFTHISMRMAAEOBSOL Project No. 6130-0342 Provided by IHSNot for ResaleNo reproduction or networking permitte
2、d without license from IHS-,-,-MS3370 REV B b1 9999912 0013201 b I FED. sup CLASS I 6130 AC INPUT: Voltage Range 112.5-117.5 Volts Frequency Range 380-420 Hertz DC OUTPUT: Voltage See Figure 3 Maximum Load Current 100 Amperes Minimum Load Current 1.0 Amperes Weight (lbs) 9.0 (Max) N T3 :i D C :I AC
3、T2 INPUT CONVERTER - - - - Figure 1. CONNECTION DIAGRAM ,A. INTERNATIONAL TITLE NAVY-AS INTEREST CONVERTER, 100 AMPERE CLASS C NONREGULATED ;her Cust AIRCRAF+ , BLAST COOLED MILITARY STANDARD MS3370 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-US3
4、370 REV B b3 - 9999932 0033202 4 = FED. sup CLASS REQUIREMENTS: The converter shall meet the requirements of MIL-C-7115 as modified below: (paragraph numbers refer to MIL-C-7115). 3.4.1.3.3 Color, Delete “color number 17875 (white)“ of first sentence and add “color number 37038 (black) .I 3.6.2.6 Co
5、olinq. The unit shall be cooled by blast air entering the unit at the terminal end and having the following characteristics: (a) Cooling air temperature may vary between -54C to 49C during ground operation and then vary linearly from 27C at sea level to 0C at 65,000 feet during flight operation. (b)
6、 Amount of cooling air shall not exceed that shown in figure 2 of this Military Standard. (c) The converter shall be able to operate continuously at +45“C at sea level with no cooling air and 35 percent rated load. Loss of Cooling Air. The unit shall not be damaged at the loss of cooling air for a p
7、eriod of 2 minutes while delivering full rated load. 3.7.1.2.3 Output starting voltage. - Add to second sentence: “except for the first 5 milliseconds from the onset of the transient, when a maximum voltage of 45 volts shall be allowed.“ 3.7.1.4.2 Tvpe II, nonregulated converters. Add: “except the c
8、onducted emission requirements of CE03, MIL-STD-461 shall be relaxed 15 db and 25 db respectively, for the output positive and negative leads from 150 KHz to 1.0 MHz.“ 3.7.1.5 Acoustical Noise. Not applicable. 3.7.1.6 Pressure drop (blast cooled converters onlv). Add: (a) Pressure drop in the unit s
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- NAVYMS3370REVB1991CONVERTER100AMPERECLASSCNONREGULATEDAIRCRAFTBLASTCOOLED 鼓风 冷却 管制 航空器 100 安培 换流 PDF

链接地址:http://www.mydoc123.com/p-984006.html