NAVY MIL-DTL-24643 30 F-2009 CABLE ELECTRICAL -20 DEGREE C TO +90 DEGREE C TYPE LS1SWU《LS1SWU型 -20 ℃~+90 ℃电缆》.pdf
《NAVY MIL-DTL-24643 30 F-2009 CABLE ELECTRICAL -20 DEGREE C TO +90 DEGREE C TYPE LS1SWU《LS1SWU型 -20 ℃~+90 ℃电缆》.pdf》由会员分享,可在线阅读,更多相关《NAVY MIL-DTL-24643 30 F-2009 CABLE ELECTRICAL -20 DEGREE C TO +90 DEGREE C TYPE LS1SWU《LS1SWU型 -20 ℃~+90 ℃电缆》.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、 INCH-POUND MIL-DTL-24643/30F 1 October 2009 SUPERSEDING MIL-DTL-24643/30E 22 August 2002 DETAIL SPECIFICATION SHEET CABLE, ELECTRICAL, -20 C TO +90 C, TYPE LS1SWU This specification is approved for use by all Departments and Agencies of the Department of Defense. The requirements for acquiring the
2、product described herein shall consist of this specification sheet and MIL-DTL-24643. Construction, Watertight First - Copper conductor, coated or uncoated, ASTM B286, Size 22 7 strands. Second - Separator may be used at manufacturers option where required to provide free-stripping insulation. Third
3、 - Thermoset insulation. Nominal wall thickness of 0.048 inch. Wall thickness may vary from nominal as necessary in order for completed cable to meet the specified electrical requirements. Fourth - Braided shield of 36 AWG, coated or uncoated copper. Braid angle of 30 to 35 degrees; minimum coverage
4、 of 85 percent. Fifth - Shield insulation of two polyester tapes, outer tape sealed. An alternate shield insulation may consist of one polyester tape, plus an extruded jacket of a suitable transparent material, minimum average thickness of the transparent material 0.003 inch. The standard identifica
5、tion code shall be applied by Method 2. Sixth - The specified number of shielded singles (see table I) shall be cabled together in accordance with 3.4.4 of MIL-DTL-24643. Cabling sequence shall be consecutive starting with no. 1 from the center outward. Fillers may be used as necessary to form a fir
6、m well-rounded assembly. Seventh - An optional binder. Eighth - Cross-linked polyolefin jacket (see table I for thickness) AMSC N/A FSC 6145 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-24643/30F TABLE I. Details. Overall diameter Military
7、 part no. M24643/30 Type and size Number of conductors Cable jacket thickness min. avg. (inch) Min. (inch) Max. (inch) -01UN LS1SWU-2 2 0.038 0.430 0.455 -02UN LS1SWU-14 14 0.050 0.825 0.870 -03UN LS1SWU-20 20 0.050 0.970 1.030 -04UN LS1SWU-30 30 0.063 1.135 1.200 REQUIREMENTS: Qualification require
8、d. INSPECTION: Basic Electricals: Conductor resistance (ohms/1000 feet at 25 C, max.) 17.2 Voltage withstand (volts, root mean square, min.) Conductor to component shield 3000 Component shield to component shield 500 Insulation resistance (megohms/1000 feet, min.) Conductor to component shield 500 C
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- NAVYMILDTL2464330F2009CABLEELECTRICAL20DEGREECTO90DEGREECTYPELS1SWULS1SWU 20 90 电缆 PDF

链接地址:http://www.mydoc123.com/p-978656.html