NAVY MIL-DTL-24643 11 E-2009 CABLE ELECTRICAL -20 DEGREE C TO +90 DEGREE C 600 VOLTS TYPE LSSSF《LSSSF型600 V -20 ℃~+90 ℃电缆》.pdf
《NAVY MIL-DTL-24643 11 E-2009 CABLE ELECTRICAL -20 DEGREE C TO +90 DEGREE C 600 VOLTS TYPE LSSSF《LSSSF型600 V -20 ℃~+90 ℃电缆》.pdf》由会员分享,可在线阅读,更多相关《NAVY MIL-DTL-24643 11 E-2009 CABLE ELECTRICAL -20 DEGREE C TO +90 DEGREE C 600 VOLTS TYPE LSSSF《LSSSF型600 V -20 ℃~+90 ℃电缆》.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、 INCH-POUND MIL-DTL-24643/11E 1 October 2009 SUPERSEDING MIL-DTL-24643/11D 22 August 2002 DETAIL SPECIFICATION SHEET CABLE, ELECTRICAL, -20 C TO +90 C, 600 VOLTS, TYPE LSSSF This specification is approved for use by all Departments and Agencies of the Department of Defense. The requirements for acqu
2、iring the product described herein shall consist of this specification sheet and MIL-DTL-24643. Construction, Non-Watertight First - Copper conductor, uncoated, 300 MCM AWG, Class G stranding (see note 1). Second - Separator may be used at manufacturers option where required to provide free-strippin
3、g insulation. Third - Thermoset insulation. Minimum average wall thickness of 0.075 inch. Fourth - Optional reinforcement. Fifth - Cross-linked polyolefin jacket bonded to the underlying insulation. Minimum average wall thickness of 0.075 inch. NOTE: The copper shall be hard drawn, having a minimum
4、tensile strength of 67,200 lb/in, and minimum elongation of 0.85 percent in 60-inch lengths before stranding. The resistance specified is based on 102.7 percent of the values required for annealed bare copper. AMSC N/A FSC 6145 Provided by IHSNot for ResaleNo reproduction or networking permitted wit
5、hout license from IHS-,-,-MIL-DTL-24643/11E TABLE I. Details. Overall diameter Military part no. M24643/11 Type and size Conductor size min. (inch) max. (inch) -01UN LSSSF-7 300 MCM (Class G) 1.020 1.100 REQUIREMENTS: Qualification required. INSPECTION: Basic Electricals: Conductor resistance (ohms/
6、1000 feet at 25 C, max.) 0.0388 Voltage withstand (volts, root mean square, min.) Conductor to ground 2500 Insulation resistance (megohms/1000 feet, min.) Conductor to ground 100 Conductor continuity No failure Group A: Visual and dimensional No failure Group B: Cold bending cable at minus 302 C two
7、 turns around No damage an 8.5“ mandrel Thermoset proof test (percent, max.) Insulation 50Jacket (when tested at 200 C) 50 Drip (951 C) Zero Physicals (unaged) Insulation (extruded) Tensile strength (lb/in2, min.) 700 Elongation (percent, min.) 150 Jacket (cable) Tensile strength (lb/in2, min.) 1300
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- NAVYMILDTL2464311E2009CABLEELECTRICAL20DEGREECTO90DEGREEC600VOLTSTYPELSSSFLSSSF 600 V20 90 电缆 PDF

链接地址:http://www.mydoc123.com/p-978635.html