FORD FLTM BO 117-02-2001 IMPACT TEST FOR PLASTICS (Replaces FLTM BO 017-02)《塑料的冲击测试 代替FLTM BO 017-02(代替 FORD FLTM BO 017-02)》.pdf
《FORD FLTM BO 117-02-2001 IMPACT TEST FOR PLASTICS (Replaces FLTM BO 017-02)《塑料的冲击测试 代替FLTM BO 017-02(代替 FORD FLTM BO 017-02)》.pdf》由会员分享,可在线阅读,更多相关《FORD FLTM BO 117-02-2001 IMPACT TEST FOR PLASTICS (Replaces FLTM BO 017-02)《塑料的冲击测试 代替FLTM BO 017-02(代替 FORD FLTM BO 017-02)》.pdf(11页珍藏版)》请在麦多课文档分享上搜索。
1、 FORD LABORATORY TEST METHOD BO 117-02 Date Action Revisions 2001 03 28 Revised Editorial no technical change A. Cockman 1996 10 16 Printed copies are uncontrolled Page 1 of 11 Copyright 2001, Ford Global Technologies, Inc. IMPACT TEST FOR PLASTICS Application This method is used to determine the im
2、pact resistance of plastics. Apparatus Required Impact Test Stand The test fixture used for this test consists of a heavy metal base to which is mounted a sample support ring of 2 inches (50.8 mm) inside diameter. The inside perimeter of the sample support is cut to 1/4 inch (6.35 mm) radius. Mounte
3、d and centered over the support ring is a carrier which holds the impact dart. The dart is free to move in its carrier and rests on the sample under static conditions. The dart has 1/2 inch (12.7 mm) diameter with one end rounded to 1/4 inch (6.35 mm) radius; the other end has a 1 inch (25.4 mm) dia
4、meter flat impact head. The dart is long enough to protrude 3/4 inch (19.1 mm) below the sample plane into the support ring. Impact weights are 1 inch (25.4 mm) diameter metal rods and are dropped through a guide tube which is mounted and centered over the impact dart. The tube has 1 1/32 inch (26.2
5、 mm) diameter and is 50 inches (1270 mm) long. Its entire length is slotted and calibrated into 1 inch (25.4 mm) increments along the slot. The weights are lifted by a pin which protrudes through the slot in the guide tube. A wide selection of weights from pound (113 g) to 10 pounds (4.54 kg) should
6、 be available so that any force range can be maintained with a weight velocity at impact of 7 to 15 ft/s (2.1 to 4.6 m/s). Guide tube calibrations are clearly marked so that when the weight is raised to a specific height and dropped, it strikes the impact dart driving it against the sample with a sp
7、ecific impact force in inch pounds. Freezer In determining cold impact strength, a chest freezer or other cooling apparatus capable of maintaining the desired temperature within +/- 2 C should be used, such as Revco Cold Box - Model ULD 1234. Source: Revco Corporation Industrial Products Division De
8、erfield, Michigan 48238 or equivalent. Samples Impact test samples should be injection molded 4 x 4 inch (102 x 102 mm) plaques with smooth surfaces and be all of the same thickness, either 0.100 inch (2.54 mm) or 0.125 inch (3.18 mm). FORD LABORATORY TEST METHOD BO 117-02 Page 2 of 11 Copyright 200
9、1, Ford Global Technologies, Inc. Conditioning and Test Conditions All test values indicated herein are based on material conditioned in a controlled atmosphere of 23 +/- 2 C and 50 +/- 5 % relative humidity for not less than 24 h prior to testing and tested under the same conditions unless otherwis
10、e specified. Test Procedure 1. Place a test sample on the support ring letting the dart rest freely on the surface of the sample. 2. Choose a weight which will deliver an impact force when dropped from 25 inches that is in the range of the expected impact resistance of the material to be tested. 3.
11、After the appropriate weight is selected, the test force increment should be set at 5 % or less of the approximate impact resistance of the material. (For very low ranges, the force increment may be as high as 10 %.) 4. Impact a few plaques to verify that the weight chosen yields both passes and fai
12、lures in the desired height range. (If more than six or seven consecutive passes are encountered, increase the force impact and start test over. Conversely, if more than six or seven consecutive failures are encountered, decrease the force and start test over). 5. After this is verified, perform the
13、 test by the following method: (a) If the sample presently being impacted fails, the next sample will be impacted at a level one increment lower. (b) If the sample presently being impacted passes, the next sample will be impacted at a level one increment higher. Failure is defined as any evidence of
14、 cracking. A minimum of 20 samples should be tested. The weight should not be allowed to bounce and strike the sample a second time. The sample should be held firmly and flat on the support ring during the entire procedure. If impact resistance is being determined at a sub-ambient temperature, the s
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- FORDFLTMBO117022001IMPACTTESTFORPLASTICSREPLACESFLTMBO01702 塑料 冲击 测试 代替 FLTMBO01702 FORDFLTMBO01702PDF

链接地址:http://www.mydoc123.com/p-747358.html