《FORD ESF-M3L86-A-2005 EPOXY POWDER ELECTRICAL INSULATION SPRAY OR FLUIDIZED BED APPLICATION TO BE USED WITH FORD WSS-M99P1111-A 《喷涂或流化床用途用电绝缘环氧树脂粉末 与标准FORD WSS-M99P1111-A一起使用 》.pdf》由会员分享,可在线阅读,更多相关《FORD ESF-M3L86-A-2005 EPOXY POWDER ELECTRICAL INSULATION SPRAY OR FLUIDIZED BED APPLICATION TO BE USED WITH FORD WSS-M99P1111-A 《喷涂或流化床用途用电绝缘环氧树脂粉末 与标准FORD WSS-M99P1111-A一起使用 》.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、 ENGINEERING MATERIAL SPECIFICATIONDate Action Revisions 2005 02 16 Revised Inserted 3.0; Deleted 3.1, 3.8, 4 1988 09 15 Released 107002-185 CF4S Printed copies are uncontrolled Copyright 2005, Ford Global Technologies, LLC Page 1 of 4 EPOXY POWDER, ELECTRICAL INSULATION ESF-M3L86-A SPRAY OR FLUIDIZ
2、ED BED APPLICATION 1. SCOPE The material defined by this specification is a finely ground epichlorohydrin bisphenol epoxy resin in dry powder form. It is applied to the surface of a part from a fluidized bed. 2. APPLICATION This specification was released originally for material used as a coating on
3、 metal for electrical insulation and corrosion protection, such as on the fuel pump motor armature for slot and end insulation. 3. REQUIREMENTS 3.0 STANDARD REQUIREMENTS FOR PRODUCTION MATERIALS Material suppliers and part producers must conform to the Companys Standard Requirements For Production M
4、aterials (WSS-M99P1111-A). 3.2 PREPARATION OF TEST BARS Six square steel bars (12.7 x 12.7 x 150 mm) having all significant surfaces ground to 0.75 - 1.25 micrometers rms shall be thoroughly degreased in at least two successive baths of trichloroethane. They shall then be coated per suppliers recomm
5、endations with 0.30 - 0.46 mm of resin on the flat surface. The bars shall then be cured for 5 min at 230 +/- 2 C in an air circulating oven. This time and temperature may be deviated provided the actual time and temperature data accompany the bars at the time of submission. Test bars which do not m
6、eet the above requirements for thickness and coverage may not be reworked for submission to this specification. 3.3 DIFFERENTIAL SCANNING CALORIMETRY The DSC thermogram for this material shall match the standard thermogram curve on file at the appropriate Materials office of the affected Product Eng
7、ineering office. The thermogram shall be generated at 20 C/min in air at 1 atmosphere (101 kPa) and shall show the Tg and the heat of reaction. ENGINEERING MATERIAL SPECIFICATIONESF-M3L86-APrinted copies are uncontrolled Copyright 2005, Ford Global Technologies, LLC Page 2 of 4 3.4 CUT THROUGH TEMPE
8、RATURE, min 300 C (Average of 2 tests) All bars must pass Test Method: See Figure 1. Mount the bar by means of clamps on a ring stand. Place a loop of 26 gage bare copper wire over the resin coated area 13 mm from the coated end. Attach a 227 g weight including any clamps or leads to the wire and pl
9、ace the test assembly in a forced air circulating type oven. Attach one lead from an 8Va-c power supply alarm circuit to the cutting wire and one to the bare end of the steel test bar. Include this lead weight as part of the 227 g load. Attach a thermocouple to the steel bar by placing in the 3.2 mm
10、 drilled hole in the bar. Secure with bolt. Start the oven and increase the temperature at a rate not to exceed 208 C/h to allow uniform heating of the test bar. When cutting wire penetrates the resin and contacts the steel bar surface the circuit will be closed and the buzzer alarm activated. Immed
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- FORDESFM3L86A2005EPOXYPOWDERELECTRICALINSULATIONSPRAYORFLUIDIZEDBEDAPPLICATIONTOBEUSEDWITHFORDWSSM99P1111A

链接地址:http://www.mydoc123.com/p-746216.html