EN 55016-1-3-2006 en Specification for radio disturbance and immunity measuring apparatus and methods Part 1-3 Radio disturbance and immunity measuring apparatus - Ancillary equipm.pdf
《EN 55016-1-3-2006 en Specification for radio disturbance and immunity measuring apparatus and methods Part 1-3 Radio disturbance and immunity measuring apparatus - Ancillary equipm.pdf》由会员分享,可在线阅读,更多相关《EN 55016-1-3-2006 en Specification for radio disturbance and immunity measuring apparatus and methods Part 1-3 Radio disturbance and immunity measuring apparatus - Ancillary equipm.pdf(36页珍藏版)》请在麦多课文档分享上搜索。
1、BRITISH STANDARDBS EN 55016-1-3:2006Specification for radio disturbance and immunity measuring apparatus and methods Part 1-3: Radio disturbance and immunity measuring apparatus Ancillary equipment Disturbance powerThe European Standard EN 55016-1-3:2006 has the status of aBritish StandardICS 33.100
2、.10; 33.100.20 BS EN 55016-1-3:2006 +A1:2016(CISPR 16-1-3:2004)BS EN 55016-1-3:2006+A1:2016ISBN 978 0 580 87135 1Amendments/corrigenda issued since publicationDate Comments31 May 2016 Implementation of IEC amendment 1:2016 with CENELEC endorsement A1:2016This British Standard was published under the
3、 authority of the Standards Policy and Strategy Committee on 31 January 2007 The British Standards Institution 2016. Published by BSI Standards Limited 2016National forewordThis British Standard is the UK implementation of EN 55016-1-3:2006+A1:2016. It is identical to CISPR 16-1-3:2004, incorporatin
4、g amendment 1:2016. It supersedes BS EN 55016-1-3:2006, which will be withdrawn on 5 May 2019.The start and finish of text introduced or altered by amendment is indicated in the text by tags. Tags indicating changes to IEC text carry the number of the IEC amendment. For example, text altered by IEC
5、amendment 1 is indicated by .The UK participation in its preparation was entrusted by Technical Committee GEL/210, EMC Policy committee, to Subcommittee GEL/210/11, EMC Standards committee.A list of organizations represented on this subcommittee can be obtained on request to its secretary.This publi
6、cation does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application.Compliance with a British Standard cannot confer immunity from legal obligations.EUROPEAN STANDARD EN 55016-1-3NORME EUROPENNE EUROPISCHE NORM November 2006 CENELEC Europe
7、an Committee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung Central Secretariat: rue de Stassart 35, B - 1050 Brussels 2006 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for
8、CENELEC members.Ref. No. EN 55016-1-3:2006 EICS 33.100.10;33.100.20 Supersedes EN 55016-1-3:2004English version Specification for radio disturbance and immunity measuring apparatus and methods Part 1-3: Radio disturbance and immunity measuring apparatus - Ancillary equipment - Disturbance power(CISP
9、R 16-1-3:2004)Spcifications des mthodes et des appareils de mesuredes perturbations radiolectriques et de limmunit aux perturbations radiolectriques Partie 1-3: Appareils de mesure des perturbations radiolectriques et de limmunit aux perturbations radiolectriques -Matriels auxiliaires - Puissance pe
10、rturbatrice (CISPR 16-1-3:2004)Anforderungen an Gerte und Einrichtungen sowie Festlegungder Verfahren zur Messungder hochfrequenten Straussendung(Funkstrungen) und StrfestigkeitTeil 1-3: Gerte und Einrichtungen zur Messung der hochfrequenten Straussendung (Funkstrungen)und Strfestigkeit -Zusatz-/Hil
11、fseinrichtungen - Strleistungsmessung(CISPR 16-1-3:2004)This European Standard was approved by CENELEC on 2006-07-01. CENELEC members are bound to complywith the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard withou
12、t any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the Central Secretariat or to any CENELEC member. This European Standard exists in three official versions (English, French, German). A version in any other language
13、 made by translation under the responsibility of a CENELEC member into its own language and notified to the Central Secretariat has the same status as the official versions. CENELEC members are the national electrotechnical committees of Austria, Belgium, Cyprus, the Czech Republic, Denmark, Estonia
14、, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and the United Kingdom. EN 55016-1-3:2006+A1May 2016Annex ZA(normative)Normative references t
15、o international publications with their corresponding European publications The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (includin
16、g any amendments) applies.NOTE When an international publication has been modified by common modifications,indicated by (mod), the relevant EN/HD applies.Publication Year Title EN/HD YearCISPR 16-1-2 2003 Specification for radio disturbance and immunity measuring apparatus and methodsPart 1-2: Radio
17、 disturbance and immunitymeasuring apparatus - Ancillary equipment -Conducted disturbancesEN 55016-1-2 2004 CISPR 16-2-2 2003 Specification for radio disturbance and immunity measuring apparatus and methodsPart 2-2: Methods of measurement ofdisturbances and immunity - Measurement ofdisturbance power
18、EN 55016-2-2 2004 CISPR 16-4-2 -1)Specification for radio disturbance and immunity measuring apparatus and methodsPart 4-2: Uncertainties, statistics and limit modelling - Uncertainty in EMC measurementsEN 55016-4-2 20042)IEC 60050-161 + A1 + A2 1990 1997 1998 International Electrotechnical Vocabula
19、ry(IEV) - Chapter 161: Electromagneticcompatibility- - - - - - 1)Undated reference.2)Valid edition at date of issue. 32 EN 55016-1-3:2006- 2 -BS EN 55016-1-3:2006+A1:2016EN 55016-1-3:2006+A1:2016ForewordThe text of the International Standard CISPR 16-1-3:2004, prepared by CISPR SC A, Radio-interfere
20、nce measurements and statistical methods, was submitted to the CENELEC Unique Acceptance Procedure and was approved by CENELEC as EN 55016-1-3 on 2006-07-01.This European Standard supersedes EN 55016-1-3:2004.In this EN 55016-1-3:2006, a more detailed calibration method for the absorbing clamp is sp
21、ecified. Furthermore, new alternative calibration methods are introduced which are more practicable than the one that was specified previously. Additional parameters to describe the absorbing clamp are defined, like the decoupling factor for the broadband absorber (DF) and the decoupling factor for
22、the current transformer (DR), along with their validation methods. A procedure for the validation of the absorbing clamp test site (ACTS) is also included in the document.The following dates were fixed: latest date by which the EN has to be implemented at national level by publication of an identica
23、l national standard or by endorsement (dop) 2007-07-01 latest date by which the national standards conflicting with the EN have to be withdrawn (dow) 2009-07-01Annex ZA has been added by CENELEC.Endorsement noticeThe text of the International Standard CISPR 16-1-3:2004, including the corrigendum Feb
24、ruary 2006, was approved by CENELEC as a European Standard without any modification.Foreword to amendment A1The text of document CIS/A/1111/CDV, future CISPR 16-1-3:2004/A1, prepared by SC A “Radio interference measurements and statistical methods” of IEC/TC CISPR “International special committee on
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- EN55016132006ENSPECIFICATIONFORRADIODISTURBANCEANDIMMUNITYMEASURINGAPPARATUSANDMETHODSPART13RADIODISTURBANCEANDIMMUNITYMEASURINGAPPARATUSANCILLARYEQUIPMPDF

链接地址:http://www.mydoc123.com/p-717383.html