1、f - i-. - i A-A-54162 65 W 7777774 0055904 5 A-A-54162 7 June 1990 COMMERCIAL ITEM DESCRIPTION CUTTER-VACUUM, ORTHOPEDIC CAST (110/230 V, 50/60 Hz, AC) The Cleneral Services Administration has authorized the use of this commercial item description. This commercial item description covers an electric
2、 motor driven saw used to cut orthopedic casts on the body without injuring the patient combined with a portable vacuum cleaner used to dispose of plaster and dust and chips. Salient characteristics: General. The orthopedic cast cutter shall consist of an electric motor within a metal or plastic hou
3、sing, an on-off line switch, and a line cord. The motor by means of the incorporated mechanism, shall impart non-rotating, high frequency, oscillating motion to the attached circular saw blade. The orthopedic vacuum cleaner shall be a compact unit mounted on wheels or casters, and shall be easily em
4、ptied. The housing shall have a handle on top or integrated with the stand assembly. The unit shall include an electric motor-driven vacuum source, an on-off switch on the housing, and shall have a flexible plastic vacuum intake tubing whose proximal end attaches to the housing with a twist lock, sn
5、ap latch, or other secure mechanism. Material. All the plastic components of both the cast cutter and vacuum cleaner shall be fabricated from materials fully capable of performing their intended function. All metal components shall be fabricated from suitable corrosion- resistant metal processed as
6、they can perform their intended function. Style. design. and dimensions. The cast cutter shall be a non-rotating, high frequency, oscillating circular saw. The motor shall operate on either 110 or 230 volts, SO or 6 Hertz (Hz). Should this motor or the vacuum cleaner motor operate on only 110 volt,
7、50/6O Hz (or 230 volt, 50/60 Hz only), then an external step-up (or step-down) transformer must be supplied with the unit. AMSC NIA FSC 6515 distribution ia unlimited. DISTRIBUTION STATEMENT A. Approved for public release; Provided by IHSNot for ResaleNo reproduction or networking permitted without
8、license from IHS-,-,-A-A-541b2 65 7997974 0055705 7 m b * A-A-54162 The motor shall be fan-cooled, permanently lubricated, universal type, rated at 0.1 horsepower or more at 10,000 revolutions per minute (RPM) continuous. Motor brush holders shall be acceseible through brush covers. The cast cutter
9、shall conform to the applicable requirements of Underwriters Laboratories (UL) Standards for Safety for Electric Tools 544.A label or listing of UL shall be acceptable as proof of the equipment conforms to the above. A copy of each report shall be furnished to the contracting officer (See Note 2). T
10、he power cord shall be a minimum of 9 feet long, 3-wire construction with appropriate 3-prong plug for operation with a vacuum cleaner having no power cord in or clipped on to the vacuum cleaner hose. For vacuum cleaners having a power cord in or clipped on to the vacuum cleaner hose, the cast cutte
11、r cord shall be one foot long and have a 3-prong plug compatible with that hose cord. In either case, the power cord shall be provided with either a spring-type component or an integrally molded component to provide cable strain relief of the housng end. Oscillatory action shall be via a cam and ope
12、n link mechanism, mechanically fastened to the offset blade arbor. Gear trangmission design is not acceptable. The housing shall be compact, rigid, and corrosion-resistant and fitted adequate gasketing to prevent oil leakage. The cleaner shall be in accordance with DPSC Drawing 24160. The vacuum cle
13、aner shall be 15 plus or minus 2 inches in diameter (including wheels) and 20 plue or minus 2 inches high (excluding the 20 inch caet cutter pole), or it shall be 9 inches in diameter and 20 inches high (20 inches diameter and 40 inches high including the stand). The 1.7 to 2 horsepower motor shall
14、be fan-cooled, permanently lubricated, sealed ball bearings capable of operating on 110 or 230 volts, 50/60 Hz. The vacuum hose shall be 1-1/4 plue or minus 1/4 inch ID and a minimum of 4-1/2 feet long. The power cord for the cast cutter which connects the caet- cutter ta the vacuum cleaner shall be
15、 located either in the hose or fastened outside at 15 inch intervals. The plug on thie cord and on the caet cutter shall be compatible. The proximal end of the hose shall attach to the vacuum cleaner inlet port with a twist-lock, snap latch, or other eecure mechanism while the distal end shall have
16、an arbor assembly which attaches over the cast cutter blade (See Note 3). The vacuum cleaner power cord shall be at least 6 feet long, 2 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-R 3 A-A-54162 b5 W 7777774 005590b 7 W A-A-54 162 Performance. Th
17、e cast cutter including power cord and plug and 2-1/2 inch blade but excluding carrying case, 2 inch blade, and wrench, shall weigh 5 pounds or less. All screws, pins, bolts, and similar parts shall be installed so they wont loosen during use. With the power cord supported or detached, the center of
18、 balance of the cast cutter shall be 6-5/16 +/- 1/2 inches from the front side of the mounted 2-1/2 inch blade measured parallel to the longitudinal axis of the housing). When operated from a 110-120 volt, 60 Hertz power source, the cast cutter no-load oscillations per minute shall be 17,000 minimum
19、. The cast cutter full-load oscillation per minute shall be 13,000 minimum. The no-load current shall be 1.2 amperes maximum. The maximum motor housing temperature rise after 5 minutes of full load operation shall be 40 degrees Fahrenheit above ambient when starting cold. The cast cutter shall be ca
20、pable of continuous operation without breakdown or failure under full load for 100 hours minimum. The switch shall function reliably and the unit shall be free of excessive noise and vibration. The vacuum cleaner shall be capable of generating a minimum of 46 inches of water suction. There shall be
21、no air leaks at the tank gasket or hose connection. At this time the power draw shall not exceed that required for 2 horsepower operation (1660 watts). The switch shall function reliably and the unit shall be free of excessive noise and vibration. When operated at 110-120 volt, 60 Hertz, at a full l
22、oad power the maximum temperature rise of the motor housing shall be 75 degrees Fahrenheit above ambient after 5 minutes of operation when started cold. The motor shall be capable of 100 hour8 continuous operation. Once a cast cutter or vacuum cleaner unit has pasged this test, a contractor need not
23、 test the unit again unless there has been a major design change in the motor and drive mechanism Accessories. Each cast cutter shall be supplied with one 2 inch and one 2-112 inch blade (See Note 4). The cast cutter shall also be supplied with a wrench as shown on Drawing 24160. Each vacuum cleaner
24、 or pole shall be supplied with a wall mounting bracket. Each vacuum cleaner shall be supplied with a semi-disposable cloth/plastic bag or filter and all other components necessary to perform its function. 3 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IH
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- DODAA541621990CUTTERVACUUMORTHOPEDICCAST110230V5060HZAC 整形外科 铸件 刀具 真空 交流电 5060 赫兹 110230 伏特 PDF

链接地址:http://www.mydoc123.com/p-701719.html