DLA MIL-PRF-1 1583 C-2012 ELECTRON TUBE IMAGE CONVERTER TYPE 6929.pdf
《DLA MIL-PRF-1 1583 C-2012 ELECTRON TUBE IMAGE CONVERTER TYPE 6929.pdf》由会员分享,可在线阅读,更多相关《DLA MIL-PRF-1 1583 C-2012 ELECTRON TUBE IMAGE CONVERTER TYPE 6929.pdf(10页珍藏版)》请在麦多课文档分享上搜索。
1、 MIL-PRF-1/1583C 19 January 2012 SUPERSEDING MIL-PRF-1/1583B 26 July 1999 PERFORMANCE SPECIFICATION SHEET ELECTRON TUBE, IMAGE CONVERTER TYPE 6929 This specification is approved for use by all Departments and Agencies of the Department of Defense. The requirements for acquiring the electron tube des
2、cribed herein shall consist of this document and the latest issue of MIL-PRF-1. DESCRIPTION: Infrared sensitive (S1 photocathode surface; P20 phosphor image screen). ABSOLUTE RATINGS: Parameter: Unit: Eb V dc Light flux lumen ib 2/ A dc Ib A dc Rb Meg TA C Alt ft Maximum: Minimum: 12,000 - - - 2.0 -
3、 0.20 - - - 68 -54 10,000 - Test condition: 12,000 1/ - - 100 20 to 23 - See the footnotes at the end of table I. GENERAL: Qualification Not required. Stabilization: 3/ Holding period: 4/ This specification sheet uses accept on zero defect sampling in accordance with MIL-PRF-1, table III. AMSC N/A F
4、SC 5960 INCH-POUND Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-1/1583C 2 TABLE I. Testing and inspection. Method Acceptance Limits Inspection MIL-STD-1311 Conditions level Symbol Min Max Unit Conformance inspection, part 1 Shock - 5/ 9/ -
5、 - - - - Irradiation surge - 6/ - - - - - Conversion index - 7/ - CI 10 - - Conversion index decay - 4/ 21/ - - - - - Conversion index to background - 8/ 21/ - CI/B 3.0 - - Alignment and image shift - 9/ - - - - - Center resolution - 10/ - Res 50 - 1-p/mm Peripheral resolution - 10/ - Res 12 - 1-p/m
6、m Center magnification - 11/ - Cmx 0.714 0.758 - Distortion - 12/ - - 6 10 % Cathode and screen spots - 13/ 21/ - - - - - Breakdown - 14/ 21/ - - - - - Dark current - Light flux = 0 15/ 21/ - Llk - 0.02 A Conformance inspection, part 2 Cathode and screen uniformity - 16/ 2.5 - - - - Vibration (1) (c
7、athode-ray tubes) 5111 9/ 17/ 20/ 1.0 - - - - Vibration (2) (cathode-ray tubes) 5111 9/ 18/ 20/ 2.5 - - - - Temperature cycling and thermal shock - 9/ 19/ 20/ 1.0 - - - - Permanence of marking 1105 - - - - - 1/ Unless otherwise specified, the radiation source shall be a tungsten filament lamp operat
8、ed at a color temperature of 2,854K. A Corning No. 2540 filter (melt No. 1613, of .103 inch (2.61 mm) thickness), or equivalent, shall be placed between the radiation source and the photocathode. The quantity of radiation from the source incident on the photocathode for the individual tests shall be
9、 the amount stated in the note describing the particular test. 2/ The period of time of ib for any single period shall not exceed 2 minutes, and the tube shall not be subjected to more than 10 such periods during its life. Provided by IHSNot for ResaleNo reproduction or networking permitted without
10、license from IHS-,-,-MIL-PRF-1/1583C 3 TABLE I. Testing and inspection - Continued. 3/ The tube shall be held for a manufacturers stabilizing period of at least 2 weeks. Prior to this period, the temperature, vibration, and shock tests shall be made; at the end of the two-week period, the irradiatio
11、n surge and initial conversion index tests shall be made in the order listed. (See 4/). 4/ After a holding period of 672 hours, which shall not include the manufacturers stabilizing period of at least 336 hours, the conversion index of the tube shall be not less than 10, and shall not have slumped m
12、ore than 20 percent from the initial value measured at the end of the stabilizing period. If the conversion index has slumped more than 20 percent, but still is above the minimum value of 10, the tube shall be held an additional 2 weeks. At the end of the 6-week period, the tube shall have a convers
13、ion index of not less than 10 and shall not have slumped more than 30 percent of the initial value. 5/ Upon completion of the vibration (1) test, specified herein, each tube, in a proper holder, shall be energized with 12,000 volts for a stabilization period of 15 seconds in a darkened room (not mor
14、e than 0.01 footcandle). At the end of this period, with the tube still energized and no incident light on the photocathode, it shall be subjected to shock impacts in the following manner: The shock impacts shall be applied in a way to generate nominal half-sine wave pulses having a minimum of 75 Gs
15、 at the peak. The duration of each shock pulse shall be 6 2 milliseconds measured between the 10 percent values of the peak amplitude. The energy under the shock curve shall be not less than 0.25 G second and the after oscillations shall be not greater than 15 percent of the peak amplitude of the no
16、minal half-sine wave pulse. The tube shall be subjected to six shock pulses parallel to, and six shock pulses perpendicular to, its longitudinal axis. Presence of flashing or electrical bursting during more than two shocks in each direction shall be cause for rejection. 6/ The image tube shall be su
17、bjected to an irradiation surge by exposing the photocathode to radiation from a tungsten light source (which need not be the one specified in 1/) for a period of at least 5.0 seconds to produce a minimum of 2.0 A of photocathode current. The image of the source on the screen of the tube shall not d
18、isintegrate nor shall any part of the image darken or be blanked out during the irradiation surge. 7/ The radiation source, specified in 1/, shall be used to produce a circular image .500 inch (12.70 mm) in diameter on the center of the photocathode. The amount of incident flux on the photocathode (
19、prior to interposing the filter) shall be 0.0100 0.0005 lumen. The light output of the tube shall be read with a Weston Model 856 RRV photronic cell, or equivalent, provided with a Viscor filter and truncated lucite cone. The cone shall be 1.562 inches (39.67 mm) in diameter at its base, 1.125 inche
20、s (28.58 mm) in diameter at its top, and 1.6875 inches (42.86 mm) in height. The base of the cone shall be cemented to the photronic cell window. The cone top shall be in contact with the image screen of the tube. The photronic cell and cone shall be precalibrated from a diffused light source. The s
21、mall end of the cone shall be placed to cover the excited area of the image screen. The conversion index is defined as: TFFCI21=F1 is the total available luminous flux emitted by the phosphor screen of the tube at the operating voltage specified herein. F2 is the unfiltered flux from the 2,854K ligh
22、t source incident on the photocathode of the tube. T is the filter factor of a calibrated Corning No. 2540 (melt number 1613, .103 inch (2.61 mm) thickness) infrared filter, or equivalent, interposed between the light source and photocathode. This filter factor is the percentage of 2,854K hololumen
23、flux transmitted by the infrared filter and is determined by the following: Where R = The relative spectral response of an EIA S-1 photosurface. J = The relative spectral distribution of the 2,854K color temperature radiation source. t = The spectral transmission of the infrared filter. d = The diff
24、erential of . = The wavelength of the radiation. TR J t dR J d= Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-1/1583C 4 TABLE I. Testing and inspection - Continued. 8/ The radiation source and filter specified in 1/ shall be used. The sourc
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- DLAMILPRF11583C2012ELECTRONTUBEIMAGECONVERTERTYPE6929PDF

链接地址:http://www.mydoc123.com/p-691993.html