DIN 51750-1-1990 Sampling of petroleum products general information《石油产品的取样 一般信息》.pdf
《DIN 51750-1-1990 Sampling of petroleum products general information《石油产品的取样 一般信息》.pdf》由会员分享,可在线阅读,更多相关《DIN 51750-1-1990 Sampling of petroleum products general information《石油产品的取样 一般信息》.pdf(6页珍藏版)》请在麦多课文档分享上搜索。
1、UDC 665.6/.7: 662.753 : 621.892:620.113 DEUTSCHE NORM December 1990 Sampling of petroleum products General information DIN - 51 750 Part 1 Prfung von Minerallen; Probenahme; Allgemeines Supersedes August 1983 edition. In keeping with current practice in standards published by the International Organ
2、ization for Standardization (ISO), a comma has been used throughout as the decimal marker. See Explanatory notes for connection with IS0 3170 : 1988 published by the International Organization for Standardization (ISO) and ASTM D 4057-88 published by the American Society for Testing and Materials (A
3、STM). 1 Field of application 1.1 a) crude oils, liquid petroleum products (e.9. engine fuels, special boiling point spirits and white spirits, fuel oils, kerosene and liquid lubricants (cf. DIN 51 750 Part 2 for sampling procedure), as well as b) pasty and solid petroleum products (e.g. lubricating
4、greases, petroleum jelly and paraffins (cf. DIN 51 750 Pari 3 for Bampling procedure). Where the petroleum product can be liquefied by heating without that chang- ing its composition, sampling may also be carried out as specified in DIN 51 750 Part 2. The DIN 51 750 series of standards covers 1.2 Th
5、is standard applies to petroleum products forming the content of one or more containers, which may vary in type and size and be completely or partly filled, or contained in a pipeline. The petroleum product may thus be flowing or non-flowing. For the purposes of this standard, a product is defined a
6、s non-flowing when inflow and ouiilow from a container are prevented and as flowing if it is conveyed in a pipeline or discharged via a container outlet. 1.3 This standard does not cover a) bituminous binders (cf. EN 58); b) lubricating oils in internal combustion engines (cf. DIN 51 574); c) liquef
7、ied natural gases (cf. DIN 51 610); d) solid fuels (cf. DIN 51 701 Part 2 to Part 4); e) gaseous fuels, inert and combustion gases (cf. DIN 51 853). 2 Scope This standard specifies methods of manual sampling of petroleum products, either by taking bulk samples or tap samples. 2.1 Bulk sampling The a
8、im of bulk sampling is to obtain a representative sample, .e. the characteristics as determined by testing may be assumed to represent the characteristics of the bulk. 2.2 lap sampling The aim of tap sampling is to obtain a sample which may be used to assess the quality of a product at its point of
9、delivery (e.g. petrol pump). 3 Concepts 3.1 Spot sample A spot sample is a sample collected at a discrete location in the container. 3.1.1 Skim sample A skim sample is a spot sample collected at a point located not more than 5 cm below the surface. 3.1.2 Top sample A top sample is a spot sample coll
10、ected 15 cm below the surface of the product. 3.1.3 Upper sample An upper sample is aspot sample collected at the mid-point of the upper third of the container contents. 3.1.4 Middle sample A middle sample is a spot sample collected at a point approximately halfway between upper and lower sampling p
11、oint. 3.1.5 Lower sampie A lower sample is a spot sample collected at the mid-point of the lower third of the container contents. 3.1.6 Boaom sample A bottom sample is a spot sample collected at the bottom surface of a container. 3.1.7 Draln sample A drain sample is a spot sample collected from the
12、draw-off point of a container or from a dispensing device at a point of delivery. Continued on pages 2 to 6 DIN 51 750 Part 7 Engl. Price group 6 uth Verlag GmbH, Berlin. has the exclusive right of sale for German Standards (DIN-Normen). 06.92 Sales No. O106 Page 2 DIN 51 750 Part 1 Table 1. Minimum
13、 number o1 packages from which one spot sample each Is to be collected Total number of packages (per batch) 1 to 3 4tO 64 65to 125 126to 216 217 to 343 344to 512 513 to 729 730 to 1000 1001 to 1331 Minimum number of packages from which one spot sample each is to be collected al I 4 5 6 7 8 9 10 11 3
14、.2 Ail-levels sample An all-levels sample is a sample collected by passing the sampler (e.g. sampling tube or bottle, or bomb-type sampler) through the total depth of a container so that all levels are represented proportionately. 3.2.1 Runnlng sample A running sample is an all-levels sample collect
15、ed by passing a sampling bottle or a bomb-type sampler through the total depth of a container. 3.3 Mainstream sample A mainstream sample is a combined sample collected with a scoop from a stream of liquid leaving a container. 3.4 Sidestream sample A sidestream sample is a sample collected from a sid
16、e- stream drawn off from the main pipeline. 3.5 Combined sample A combined sample is a blend of spot samples. 3.6 Composite sample A composite sample is obtained by combining a number of spot samples taken according to a sampling plan in given proportions so as to obtain a sample representative of t
17、he bulk of a product. 3.7 Laboratory sample A laboratory sample is the sample submitted to the laboratory for examination. For individual examinations (e.9. for analyses), specimens are taken from that sample, which may have undergone special treatment. If the vapour pressure of a product is to be d
18、etermined, decantation of the sample is not permitted. 3.8 Representative sample A representative sample is a sample which reproduces as closely as possible the average characteristics of the bulk. 4 General conditions for collecting 4.1 Sampling from containers of capacity not exceeding 5 ms 4.1.1
19、Sample type If the contents of a container can be assumed to be homogeneous, a spot sample shall be considered repre- sentative, otherwise an all-levels sample is to be collected. representalive samples Total number of packages (per batch) 1332 to 1728 1729 to 2197 2198 to 2744 2745 to 3375 3376 to
20、4096 4097 to 4913 4914 to 5832 5833 to 6859 6860 or more Minimum number of packages from which one spot sample each is to be collected 12 13 14 15 16 17 18 19 20 4.1.2 Sample size If the bulk, whatever its volume, of a homogeneous product takes up more than one barrel, drum or other small container
21、with a capacity not exceeding 5 m3, the number of containers from which one spot sample each is to be taken is specified for liquid petroleum products in table 1, and for pasty and solid petroleum products in table 2. The mini- mum numbers stated are generally large enough to obtain representative s
22、amples. If the total batch of a product has been transferred to containers of different sizes, all containers of one size shall be considered a separate batch. 4.1.3 Combination of spot samples Spot samples may be blended to form a combined sample il the product in a number of containers seems to be
23、 homogeneous. Otherwise, .e. if the barrels bear different markings, if they have a different temperature, or if there are differences in sample appearance or in the weather conditions they have been exposed to, only the spot samples that appear homogeneous shall be combined. When combining samples,
24、 due attention shall be paid to the specifications of subclause 3.7, second paragraph, and clause 6. 4.2 Sampling from containers of capacity exceeding 5 ms 4.2.1 Spot samples A spot sample collected from a container of capacity exceeding 5 m3 may be regarded as representative if the product is know
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- DIN5175011990SAMPLINGOFPETROLEUMPRODUCTSGENERALINFORMATION 石油 产品 取样 一般 信息 PDF

链接地址:http://www.mydoc123.com/p-658641.html