CLC TS 50625-3-4-2017 Collection logistics & treatment requirements for WEEE - Part 3- 4 Specification for de-pollution - temperature exchange equipment.pdf
《CLC TS 50625-3-4-2017 Collection logistics & treatment requirements for WEEE - Part 3- 4 Specification for de-pollution - temperature exchange equipment.pdf》由会员分享,可在线阅读,更多相关《CLC TS 50625-3-4-2017 Collection logistics & treatment requirements for WEEE - Part 3- 4 Specification for de-pollution - temperature exchange equipment.pdf(64页珍藏版)》请在麦多课文档分享上搜索。
1、Collection, logistics unless notes are in a new sub-clause or involve notes in Part 3-1, they are numbered starting from 101, including those in a replaced clause or sub-clause; additional annexes are lettered AA, BB, etc. PD CLC/TS 50625-3-4:2017CLC/TS 50625-3-4:2017 (E) 5 Introduction In order to
2、support EN 50625-2-3, Collection, logistics VHC,step 1= TargetValueVFC;step1,1-4+ TargetValueVHC;step1,1-4+ TargetValueVFC;step1,5-6+ TargetValueVHC;step1,5-6In cases where the output refrigerants are not captured in vessels but converted in a step 3 plant, the output raw gas data (mass flow of VFC
3、and VHC) of step 1 treatment shall be taken to calculate output masses during the day-to-day performance according to Annex HH. In those plants the value for TargetValueVFC;VHC,step1 shall be calculated analogously to those step 1 treatment plants where the refrigerants are captured in vessels. The
4、mass of actual weekly removed and captured or converted refrigerant shall be equal or higher than TargetValueVFC;VHC,step 1.PD CLC/TS 50625-3-4:2017CLC/TS 50625-3-4:2017 (E) 8 The monitoring of the oil output masses from classes 1-6 appliances shall be done analogously to the monitoring of the refri
5、gerant masses. The target value for the removal and capturing of oil shall be calculated analogously to the target value for refrigerants. 4.102.2.2 Further requirements concerning step 1 treatment 4.102.2.2.1 Monitoring of input and output masses in step 1 treatment The overall weekly mass balance
6、of all input masses and all output fraction masses in step 1 treatment shall not differ more than 5 %. 4.102.2.2.2 Limit value for residual refrigerant content in oil According to EN 50625-2-3:2017, 5.6.102.9, the treatment operator shall take samples of oil and send them to the laboratory. Sampling
7、 and analysing shall be done on the basis of Clause 12 of this Technical Specification. The limit value for the residual refrigerant (VFC / VHC) in the output oil is 0,2 %. 4.102.2.2.3 Limit value for residual oil in compressors According to EN 50625-2-3:2017, 5.6.102.9, there shall be a monthly ana
8、lysis of remaining oil masses in compressors directly after leaving the step 1 suction process and compressors designated to send for further treatment at an acceptor facility. All oil shall be considered removed in step 1 treatment if the residual amount of oil in the compressors is in average less
9、 than 15 g (=limit value) directly after the suction process. Compressors leaving the treatment plant for further treatment shall have no oil to the greatest possible extend (non-dripping). All oil removed from the compressors (including the oil removed before the compressors are leaving the treatme
10、nt plant) shall be degassed. NOTE It is acknowledged that current techniques do not remove the oil that is caught in the compression chambers. For the purpose of these requirements, the treatment operator shall control at least 3 compressors directly after the suction process and at least 3 compress
11、ors leaving the plant. For the evaluation of the evacuation performance, the evacuated compressors shall be opened horizontally. That has to be done at a height of approximately 2/3 with a flexible-blade saw so that the motor can be removed. The remaining quantity of oil shall be determined and reco
12、rded. The procedure shall be documented by photographing it. If the average residual amount of oil in the opened compressors directly after the suction process exceeds the limit value of in average 15 g then the residual amount of 10 further compressors shall be determined. If the limit value is sti
13、ll exceeded, measures to optimize the suction process have to be taken. The measures shall be documented and photographed and a new analysis shall be performed to verify their efficiency until the problem is solved. 4.102.2.2.4 Limit value for residual VFC in output refrigerants and oil at VHC step
14、1 treatment plants According to EN 50625-2-3:2017, 5.6.102.4 and 5.6.102.9, all output refrigerant and oil vessels of step 1 treatment plants, designated to remove and capture entirely VHC, shall be controlled regarding the content of VFC. Sampling and analysing of the vessels shall be done in accor
15、dance with Clause 12 of this Technical Specification. The limit value for residual VFC in output VHC refrigerants and oil in the vessel is 0,01 %. NOTE This limit value is derived by taking into account the lower detection limit. This requirement is also applicable for the VHC stream of step 1 treat
16、ment plants where VFC and VHC appliances are treated in separate batch streams. All measurement procedures shall be subject of documentation. PD CLC/TS 50625-3-4:2017CLC/TS 50625-3-4:2017 (E) 9 4.102.2.2.5 Limit value for phased out VFCs in non-phased out VFCs claimed for recycling According to EN 5
17、0625-2-3:2017, 5.6.102.4, all output refrigerant and oil vessels of step 1 treatment plants, designated to remove and capture only non-phased out VFC, shall be controlled regarding the content of phased out VFC. Sampling and analysing of the vessels shall be done on in accordance with Clause 12 of t
18、his Technical Specification. The limit value for phased out VFCs in non-phased out VFCs refrigerants in the vessel is 0.01 % NOTE This limit value is derived by taking into account the lower detection limit. 4.102.3 Requirements for day-to-day business of step 2 treatment plants 4.102.3.1 Monitoring
19、 of input and output masses in the step 2 treatment The overall weekly mass balance of all input masses and all output fraction masses in step 2 treatment shall not differ more than 5 %. 4.102.3.2 Target value for blowing agent output masses 4.102.3.2.1 General The expected masses of removed and cap
20、tured VFC- and VHC - blowing agents shall be calculated on base of the actual weekly input to the plant. Starting point for the calculation is the actual mix of VFC- and VHC - class 1 appliances to class 6 appliances, the respective foam weight wi of the different classes and the potential concentra
21、tion of the blowing agent (fVFC and fVHC) in the original polyurethane foam before treatment. Missing doors have to be considered as being 20 % of the foam mass of the respective appliance and the respective appliance class. Furthermore, other VFC/VHC sources in the input have to be considered for t
22、he calculation. The following values for the concentration of VFC in VFC-polyurethane (input) and values for the concentration of VHC in VHC-polyurethane (input) (fVFC / fVHC) are applicable in all European countries: fVFC= 82 g/kg fVHC= 38 g/kg For class 1 appliances to class 6 appliances the mass
23、of expected VFC- blowing agent during the weekly evaluation period on base of the number (Ci) of VFC polyurethane containing appliances per class treated is to be calculated as follows: 6;1 6 ; ;1= VFC i VFC VFC i VFCiM w fCAnalogously the mass of expected VHC- blowing agent during the weekly evalua
24、tion period on base of the number (Ci) of VHC polyurethane containing appliances per class treated is to be calculated as follows: 6;1 6 ; ;1= VHC i VHC VHC i VHCiM w fC For other materials containing VFC or VHC the expected mass of blowing agents are to be calculated on base of the actual total foa
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- CLCTS50625342017COLLECTIONLOGISTICSTREATMENTREQUIREMENTSFORWEEEPART34SPECIFICATIONFORDEPOLLUTIONTEMPERATUREEXCHANGEEQUIPMENTPDF

链接地址:http://www.mydoc123.com/p-629616.html