CEPT T CD 01-09 E-1985 Engineering Requirements for a Telegraph Modem《电报调制解调器工程要求》.pdf
《CEPT T CD 01-09 E-1985 Engineering Requirements for a Telegraph Modem《电报调制解调器工程要求》.pdf》由会员分享,可在线阅读,更多相关《CEPT T CD 01-09 E-1985 Engineering Requirements for a Telegraph Modem《电报调制解调器工程要求》.pdf(8页珍藏版)》请在麦多课文档分享上搜索。
1、CEPT T/CD*OL-OS*E 79 = 2326434 0003356 3 - - Recommendation T/CD O1 -09 E (Ostende 1979, revised at Cannes 1983) concerning the engineering requirements for a telegraph modem Recommendation proposed by Working Group T/WG 10 “Data Communications” (CD) Text of the revised Recommendation adopted by the
2、 “TelecommlticatoIls” Coinmission: “The Conference of European Post and Telecommunications Administrations, Considering - that Recommendation T/CD 01-01 contains the text of the Specifications of the general engineering requirements - that working groupe CD has studied the harmonization of such a mo
3、dem under the auspices of Question CD 1. for data circuit terminating equipment for analogue and digital networks; Recommends - that the attached Specification of engineering requirements for a telegraph modem as contained in the Annex to this Recommendation should be taken into account by all CEPT
4、Administrations when implementation of such types of equipment is being planned by Administrations.” Administrations are free to stipulate additional requirements, and also which of the optional requirements, if any, are to be provided. Note 1: The specification is subject of continuous study and po
5、ssible amendment. Note 2: The Annex is an integral part of the Recommendation. O Edition of November 30, 1985 T/CD O1 -09 E Page 3 Annex 1 . Contents Section A . Common requirements 5 1 . General. 5 2 . Modulation rate 6 3 . Interfaces (Il or 14) 4 . Modulation and coding . 5 . Line signal levels an
6、d terminating impedance 6 6 7 6 . Out-of-band interference 7 7 . Performance requirements . 7 8 . Testing and measuring requirements . 9 . Failure conditions on the digital interface . 10 . Construction and speci6c design requirements . 8 11 . Powersupply . 8 Section B . Network dependent requiremen
7、ts . 9 1 . Electrical characteristics 9 Section C . Optional requirements. . 9 1 . Interchange circuits Indication of received line signal level . 8 8 O 12 . Environmental requirements . 9 9 9 2 . Edition of November 30. 1985 . . . CEPT T/CD*OL-OS*E 79 2326414 0003358 5 W T/CD O1 -09 E Page 5 Sectio
8、n A. Cottittion reqrirertieiits 1. GENERAL This specification defines the facilities and performance requirements of a frequency shift modulation means for providing telex and telegraph transmission over voice band circuits. The specification is generally in accordance with CCITT Recommendation R.20
9、. The modulation means shall be provided by a modulator and demodulator, together with line terminating facilities for simultaneous transmission and reception of signals at modulation rates up to 300 bit/s over two-wire presented circuits. The modulator, demodulator, and line terminating facilities
10、shall hereinafter be referred to as the Telegraph Modem (TM). Two types of TM will be used, the choice depending normally on the physical location of the modem: TM (A) = equipment in the exchange or in a multiplexer; TM (B) = that part (transmission unit) of the subscriber equipment which can be use
11、d as a plug-in unit in e.g. the following equipment: TelexQ Subscriber I Line I Exchange or multiplexer* Teleprinter I Conkectirig I 1; i I unit Public data network (classe 1 and 21 I X20 bis x20 I * T = telegraph interface (e.g. 2-wire single current, 4-wire single current, 4-wire double current).
12、* If the TM (A) is used in a R101-multiplexer, I3 = external tributary interface, and I4 = internal tributary interface. When the modem is used in conjunction with equipment other than a customers station or exchange, i.e. transmission or test equipment, the modem working to a customers station will
13、 normally be a TM (A), and the modem working to an exchange will normally be a TM (B). In the situation whereby two similar equipments are working to each other, e.g. station to station or exchange to exchange, one end will be declared the “A” end and will incorporate a TM (A). Conversely the other
14、end will be described as the “B” end and will incorporate a TM (B). The decision as to which is the “A” end is arbitrary in this situation. Edition of November 30, 1985 CEPT T/CD*OL-OS*E 232b414 0003159 7 T/CD 01-09 E Page 6 2. 3. 3.1. 3.1.1. 4.1 4.2. 4.3. MODULATION RATE The modulation rate shall b
15、e up to 300 baud. INTERFACES (I1 or 14) Interchange circuits Functional characteristics The following table gives a list of interchange circuits used in TM (B) as Il and in TM (A) as 14. Interchange Direction designation Data input Data output Electrical characteristics Depending on the implementati
16、on the electrical characteristics should be V.28 compatible or of logic level. MODULATION AND CODING The modulation is a binary modulation obtained by frequency shift. No coding restrictions shall be imposed by the telegraph modem. Line interface (I2 or 13) The following table gives a list of interc
17、hange circuits used in TM (B) as 12 and in TM (A) as 13. if TM (A) or TM (B) is not an integrated part of telex or other equipments, then the same connector should be used to accommodate both I1 and 12, or 13 and 14, respectively. TM (BI (a) Transmitted data: (TM (B) to TM (A) The TM (B) shall conve
18、rt the serial binary telegraph signals into the nominal characteristic frequencies. The frequencies are defined below: Nominal mean frequency (Hz) 1,750 Characteristic frequencies (Hz) FA: binary O (space) 1,850 F,: binary 1 (mark) 1,650 The characteristic frequencies as measured at the modulator ou
19、tput must not differ by more than f 3 Hz from the nominal frequencies. (b) Received data: (TM (B) from TM (A) The TM (B) shall convert the received line signal to serial binary telegraph signals. The conversion shall be as defined below: 1,180 f9 Hz = binary O (space) 980f9 Hz = binary 1 (mark) Freq
20、uency deviation (Hz) f 100 TM (A) (a) Transmitted data: (TM (A) to TM (B) The TM (A) shall convert the serial binary telegraph signals into the nominal characteristic frequencies. The frequencies are defined below: Nominal mean frequency (Hz) 1,080 Characteristic frequencies (Hz) FA: binary O (space
21、) 1,180 F,: binary 1 (mark) 980 The caracteristic frequencies as measured at the modulator output must not differ by more than f. 3 Hz Frequency deviation (Hz) f. 100 a Edition of November 30. 1985 from the nominal frequencies. 5. 5.1. 5.2. 5.3. 5.4. 6. 7. CEPT T/CD*OL-OS*E 79 2326434 0003160 3 T/CD
22、 01-09 E Page 7 (b) Received data: (TM (A) from TM (B) The TM (A) shall convert the received line signal to serial binary telegraph signals. The conversion shall be as defined below: 1,850f9 Hz = binary O (space) 1,650f9 Hz = binary 1 (mark) LINE SIGNAL LEVELS AND TERMINATING IMPEDANCE The line inte
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- CEPTTCD0109E1985ENGINEERINGREQUIREMENTSFORATELEGRAPHMODEM 电报 调制解调器 工程 要求 PDF

链接地址:http://www.mydoc123.com/p-592992.html