CEN TS 16819-2015 Postal services - Parcel boxes for end use - Technical features《邮政服务 包裹盒的终端使用 技术特点》.pdf
《CEN TS 16819-2015 Postal services - Parcel boxes for end use - Technical features《邮政服务 包裹盒的终端使用 技术特点》.pdf》由会员分享,可在线阅读,更多相关《CEN TS 16819-2015 Postal services - Parcel boxes for end use - Technical features《邮政服务 包裹盒的终端使用 技术特点》.pdf(24页珍藏版)》请在麦多课文档分享上搜索。
1、BSI Standards PublicationPostal services Parcel boxes for end use Technical featuresPD CEN/TS 16819:2015National forewordThis Published Document is the UK implementation of CEN/TS 16819:2015.The UK participation in its preparation was entrusted to TechnicalCommittee SVS/4, Postal services.A list of
2、organizations represented on this committee can be obtained onrequest to its secretary.This publication does not purport to include all the necessary provisions ofa contract. Users are responsible for its correct application. The British Standards Institution 2015.Published by BSI Standards Limited
3、2015ISBN 978 0 580 88556 3ICS 03.240Compliance with a British Standard cannot confer immunity fromlegal obligations.This Published Document was published under the authority of theStandards Policy and Strategy Committee on 30 November 2015.Amendments/corrigenda issued since publicationDate Text affe
4、ctedPUBLISHED DOCUMENTPD CEN/TS 16819:2015TECHNICAL SPECIFICATION SPCIFICATION TECHNIQUE TECHNISCHE SPEZIFIKATION CEN/TS 16819 October 2015 ICS 03.240 English Version Postal services - Parcel boxes for end use - Technical features Services postaux - Botes colis pour utilisation finale -Caractristiqu
5、es techniques Postalische Dienstleistungen - Paketboxen fr den Endverbrauch - Technische Merkmale This Technical Specification (CEN/TS) was approved by CEN on 26 June 2015 for provisional application. The period of validity of this CEN/TS is limited initially to three years. After two years the memb
6、ers of CEN will be requested to submit their comments, particularly on the question whether the CEN/TS can be converted into a European Standard. CEN members are required to announce the existence of this CEN/TS in the same way as for an EN and to make the CEN/TS available promptly at national level
7、 in an appropriate form. It is permissible to keep conflicting national standards in force (in parallel to the CEN/TS) until the final decision about the possible conversion of the CEN/TS into an EN is reached. CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyp
8、rus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey andUnited Kin
9、gdom. EUROPEAN COMMITTEE FOR STANDARDIZATION COMIT EUROPEN DE NORMALISATION EUROPISCHES KOMITEE FR NORMUNG CEN-CENELEC Management Centre: Avenue Marnix 17, B-1000 Brussels 2015 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. CEN/TS 16
10、819:2015 EPD CEN/TS 16819:2015CEN/TS 16819:2015 (E) 2 Contents Page European foreword . 4 1 Scope 5 2 Normative references 5 3 Terms and definitions . 5 4 Classification, designation and coding 6 4.1 Parcel box types . 6 4.2 Parcel sizes 6 4.3 Corrosion resistance 6 4.4 Security . 6 5 Requirements .
11、 7 5.1 General requirements . 7 5.2 Components 7 5.3 Dimensions 7 5.3.1 Parcel box dimensions 7 5.3.2 Gauge parcel 7 5.4 Ergonomics and safety 7 5.4.1 Installation height of the box and lock 7 5.4.2 Safety . 8 5.4.3 Fire protection regulations . 9 5.5 Corrosion and water penetration . 9 5.5.1 Genera
12、l 9 5.5.2 Water penetration 9 5.6 Security . 9 5.6.1 Security requirements 9 5.6.2 Security door and locks . 9 5.6.3 Fixings 10 5.6.4 Casing strength 10 5.6.5 Other door systems . 10 6 Test methods . 10 6.1 General test requirements 10 6.2 Components . 10 6.3 Dimensions . 10 6.4 Ergonomics and safet
13、y . 11 6.4.1 Installation height of the parcel box and lock . 11 6.4.2 Safety 11 6.5 Corrosion and water penetration 11 6.5.1 Corrosion . 11 6.5.2 Water penetration . 11 6.6 Security 11 6.6.1 Security of door and locks . 11 6.6.2 Fixings 13 6.6.3 Casing Strength . 13 6.6.4 Other door systems . 13 PD
14、 CEN/TS 16819:2015CEN/TS 16819:2015 (E) 3 6.6.5 Marking, labelling and packaging . 13 Annex A (normative) Dimensions 15 Annex B (informative) Installation height of access door . 16 Annex C (informative) Security 17 Annex D (informative) Ventilation test . 19 Bibliography . 20 PD CEN/TS 16819:2015CE
15、N/TS 16819:2015 (E) 4 European foreword This document (CEN/TS 16819:2015) has been prepared by Technical Committee CEN/TC 331 “Postal services”, the secretariat of which is held by NEN. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent righ
16、ts. CEN and/or CENELEC shall not be held responsible for identifying any or all such patent rights. This document has been prepared under a mandate given to CEN by the European Commission and the European Free Trade Association. According to the CEN-CENELEC Internal Regulations, the national standar
17、ds organizations of the following countries are bound to announce this Technical Specification: Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania,
18、 Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom. PD CEN/TS 16819:2015CEN/TS 16819:2015 (E) 5 1 Scope This Technical Specification describes the technical features of parcel boxes for end use. This cover
19、s technical features such as size of parcels, ergonomics and safety, corrosion and water penetration resistance and security of delivery. 2 Normative references The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For da
20、ted references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 1670, Building hardware - Corrosion resistance - Requirements and test methods EN 13724:2013, Postal services - Apertures of private letter box
21、es and letter plates - Requirements and test methods EN 60529, Degrees of protection provided by enclosures (IP Code) (IEC 60529) 3 Terms and definitions For the purposes of this document, the terms and definitions given in EN 13724:2013 and the following apply. 3.1 parcel box receptacle intended to
22、 receive parcel delivered by postal and/or parcel operators 3.2 parcel box components all parts supplied by the manufacturer of the parcel boxes 3.3 access door opening through which a parcel is delivered 3.4 casing enclosure receiving the parcels delivered excluding the box door 3.5 door generally
23、flat, whose purpose is to cover and/or seal an opening Note 1 to entry: Doors can open inwards or outwards. 3.6 parcel packed item with name and address of the recipient to be delivered by a postal and/or parcel operator 3.7 parcel reception area complete area inside a parcel box where a parcel of t
24、he size XS can be placed PD CEN/TS 16819:2015CEN/TS 16819:2015 (E) 6 3.8 gauge parcel parcel used to test the clear delivery of parcels 3.9 lock mechanism locking device which is operated mechanically, electronically or by other means 3.10 delivery floor level floor level on the delivery side of the
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- CENTS168192015POSTALSERVICESPARCELBOXESFORENDUSETECHNICALFEATURES 邮政 服务 包裹 终端 使用 技术 特点 PDF

链接地址:http://www.mydoc123.com/p-592703.html