CEN TR 17179-2018 Thermoplastics piping and ducting systems - Rainwater infiltration and storage attenuation systems - Practices for underground installation.pdf
《CEN TR 17179-2018 Thermoplastics piping and ducting systems - Rainwater infiltration and storage attenuation systems - Practices for underground installation.pdf》由会员分享,可在线阅读,更多相关《CEN TR 17179-2018 Thermoplastics piping and ducting systems - Rainwater infiltration and storage attenuation systems - Practices for underground installation.pdf(24页珍藏版)》请在麦多课文档分享上搜索。
1、BSI Standards PublicationWB11885_BSI_StandardCovs_2013_AW.indd 1 15/05/2013 15:06Thermoplastics piping and ducting systems - Rainwater infiltration and storage attenuation systems - Practices for underground installationPD CEN/TR 17179:2018National forewordThis Published Document is the UK implement
2、ation of CEN/TR 17179:2018.The UK participation in its preparation was entrusted to Technical Committee PRI/88, Plastics piping systems.A list of organizations represented on this committee can be obtained on request to its secretary.This publication does not purport to include all the necessary pro
3、visions of a contract. Users are responsible for its correct application. The British Standards Institution 2018 Published by BSI Standards Limited 2018ISBN 978 0 580 51465 4ICS 13.060.30; 23.040.20; 23.040.05Compliance with a British Standard cannot confer immunity from legal obligations. This Publ
4、ished Document was published under the authority of the Standards Policy and Strategy Committee on 31 March 2018.Amendments/corrigenda issued since publicationDate Text affectedPUBLISHED DOCUMENTPD CEN/TR 17179:2018TECHNICAL REPORTRAPPORT TECHNIQUETECHNISCHER BERICHTCEN/TR 17179January 2018ICS 13.06
5、0.30; 23.040.05; 23.040.20EUROPEAN COMMITTEE FOR STANDARDIZATIONCOMIT EUROPEN DE NORMALISATIONEUROPISCHES KOMITEE FR NORMUNGCEN-CENELEC Management Centre: Avenue Marnix 17, B-1000 Brussels 2018 CEN Ref. No. CEN/TR 17179:2018: EAll rights of exploitation in any form and by any means reserved worldwid
6、e for CEN national MembersThermoplastics piping and ducting systems - Rainwater infiltration and storage attenuation systems - Practices for underground installationSystmes de canalisations et de gaines en matires thermoplastiques - Pratiques pour la pose en enterreEinbauanleitungen fr Rohrleitungs-
7、, Regenwasserversickerungs- und Regenrckhaltungshaltesysteme auerhalb von Gebuden - Verfahren fr den ErdeinbauThis Technical Report was approved by CEN on 17 December 2017. It has been drawn up by the Technical Committee CEN/TC 155.CEN members are the national standards bodies of Austria, Belgium, B
8、ulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Swit
9、zerland, Turkey and United Kingdom.English VersionCEN/TR 17179:2018 (E)European foreword 3Introduction . 41 Scope . 52 Normative references 53 Terms and definitions . 54 Symbols and abbreviations . 75 Transport, handling and storage at depots and sites . 75.1 General . 75.2 Transportation of boxes a
10、nd box components 75.3 Handling 85.4 Storage . 86 Installation . 86.1 Behaviour of reservoirs . 86.2 Design considerations. 96.2.1 General 96.2.2 Types of installation 96.3 Excavation construction 96.3.1 Safety 96.3.2 Excavation width . 96.3.3 Excavation depth.106.3.4 Excavation bottom .106.4 Reserv
11、oir installation, procedures and control .116.4.1 Handling . 116.4.2 Installation using geotextile (infiltration or attenuation) .116.4.3 Installation using geomembranes (storage or attenuation) .126.5 Backfilling . 136.5.1 General. 136.5.2 Basic procedure .136.5.3 Side and initial backfill 136.5.4
12、Recommended compaction methods 146.5.5 Main backfill156.5.6 Compaction quality control . 166.6 Special precautions 167 Ancillary components 168 Inspection and testing .178.1 Inspection . 178.1.1 Inspection before installation 178.1.2 Inspection after installation 178.2 Testing - Leak tightness testi
13、ng for storage or watertight attenuation system 17Annex A (informative) Classification of soils 18Bibliography .202Contents PagePD CEN/TR 17179:2018CEN/TR 17179:2018 (E)European forewordThis document (CEN/TR 17179:2018) has been prepared by Technical Committee CEN/TC 155 “Plastics piping systems and
14、 ducting systems”, the secretariat of which is held by NEN.Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CEN shall not be held responsible for identifying any or all such patent rights.3PD CEN/TR 17179:2018CEN/TR 17179:2018 (E)I
15、ntroductionEcological and sustainable rainwater management is an increasingly important subject for communities, designers and other agencies. Due to the increasing amount of impermeable surfaces being created by buildings and roads, rainwater falling in urban areas can have great difficulty in find
16、ing its way into the ground or to receiving surface water. This can cause flash flooding, water in basements and other life threatening situations.Rainwater harvesting, infiltration and decentralized retention of rainwater (attenuation), are examples of ecological and sustainable rainwater managemen
17、t. Excess water from rainwater harvesting systems should be infiltrated into the ground or released in a controlled manner into surface water bodies. Plastic geocellular systems, sometimes referred to as boxes, are a preferred solution for temporarily storing rainwater underground. These boxes can b
18、e stacked in layers to form underground storage reservoirs (e.g. tanks) able to store run-off from intensive rainfall falling over large surface areas. Plastic boxes have the advantage of being light and easy to install whilst providing a large capacity for storage relative to their overall volume.
19、Some boxes are strong enough to be installed under roads, parking areas and other landscape features. They can also be recycled very easily.This Technical Report contains guidance for installation procedures for thermoplastic infiltration and attenuation systems outside building structures, which sh
20、ould be completed in conjunction with product specific installation instructions.This Technical Report is a guidance document only. It provides a set of general guidelines which gives best practice for underground installation of thermoplastic infiltration and attenuation systems outside building st
21、ructures.This Technical Report includes recommendations for the reservoir surround and backfilling procedures but not road base and road sub-base details. Attention is drawn to any national regulations which may cover these or other aspects of installation.This Technical Report is intended to be use
22、d by local authorities, design engineers, installation contractors and manufacturers.In this Technical Report, much of the guidance is expressed as requirements, e.g. by use of “shall” or by instructions in the imperative. It is strongly recommended that these be followed whenever applicable.Other g
23、uidance is presented for consideration as a matter of judgement in each case, e.g. by use of “should”.4PD CEN/TR 17179:2018CEN/TR 17179:2018 (E)1 ScopeThis Technical Report is applicable to the installation of rainwater infiltration and storage/attenuation systems under gravity.This Technical Report
24、 covers installations including: reservoirs made by assembled cuboid shaped thermoplastic boxes; integral components; ancillary components (e.g. access provisions and connections); geotextiles and/or geomembranes; embedment and backfill.These systems are intended for underground use in landscape, pe
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- CENTR171792018THERMOPLASTICSPIPINGANDDUCTINGSYSTEMSRAINWATERINFILTRATIONANDSTORAGEATTENUATIONSYSTEMSPRACTICESFORUNDERGROUNDINSTALLATIONPDF

链接地址:http://www.mydoc123.com/p-592362.html