BS ISO 12219-3-2012 Interior air of road vehicles Screening method for the determination of the emissions of volatile organic compounds from vehicle interior parts and materials Mi.pdf
《BS ISO 12219-3-2012 Interior air of road vehicles Screening method for the determination of the emissions of volatile organic compounds from vehicle interior parts and materials Mi.pdf》由会员分享,可在线阅读,更多相关《BS ISO 12219-3-2012 Interior air of road vehicles Screening method for the determination of the emissions of volatile organic compounds from vehicle interior parts and materials Mi.pdf(32页珍藏版)》请在麦多课文档分享上搜索。
1、raising standards worldwideNO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAWBSI Standards PublicationBS ISO 12219-3:2012Interior air of road vehiclesPart 3: Screening method for thedetermination of the emissions of volatileorganic compounds from vehicle interiorparts and materia
2、ls Micro-scale chambermethodBS ISO 12219-3:2012 BRITISH STANDARDNational forewordThis British Standard is the UK implementation of ISO 12219-3:2012.The UK participation in its preparation was entrusted to TechnicalCommittee EH/2/3, Ambient atmospheres.A list of organizations represented on this comm
3、ittee can beobtained on request to its secretary.This publication does not purport to include all the necessaryprovisions of a contract. Users are responsible for its correctapplication. The British Standards Institution 2012. Published by BSI StandardsLimited 2012ISBN 978 0 580 72178 6ICS 13.040.20
4、; 43.020Compliance with a British Standard cannot confer immunity fromlegal obligations.This British Standard was published under the authority of theStandards Policy and Strategy Committee on 30 June 2012.Amendments issued since publicationDate Text affectedBS ISO 12219-3:2012 ISO 2012Interior air
5、of road vehicles Part 3: Screening method for the determination of the emissions of volatile organic compounds from vehicle interior parts and materials Micro-scale chamber methodAir intrieur des vhicules routiers Partie 3: Mthode de criblage pour la dtermination des missions de composs organiques v
6、olatils des parties et matriaux intrieurs des vhicules Mthode de la micro-chambreINTERNATIONAL STANDARDISO12219-3First edition2012-06-15Reference numberISO 12219-3:2012(E)BS ISO 12219-3:2012ISO 12219-3:2012(E)ii ISO 2012 All rights reservedCOPYRIGHT PROTECTED DOCUMENT ISO 2012All rights reserved. Un
7、less otherwise specified, no part of this publication may be reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying and microfilm, without permission in writing from either ISO at the address below or ISOs member body in the country of the requester.ISO
8、copyright officeCase postale 56 CH-1211 Geneva 20Tel. + 41 22 749 01 11Fax + 41 22 749 09 47E-mail copyrightiso.orgWeb www.iso.orgPublished in SwitzerlandBS ISO 12219-3:2012ISO 12219-3:2012(E) ISO 2012 All rights reserved iiiContents PageForeword ivIntroduction v1 Scope 12 Normative references . 13
9、Terms and definitions . 24 Principle . 25 Apparatus 26 Test conditions . 36.1 Temperature 46.2 Air or gas flow rate through the micro-scale chamber . 46.3 Quality of supplied air or gas and background concentration of organic vapours 46.4 Control measures 47 Test specimens 47.1 General . 47.2 Prepar
10、ation of the test specimen 58 Cleaning micro-scale chamber components . 59 Test method 59.1 Sampling media . 59.2 Measuring background concentrations 69.3 Vapour sampling 69.4 Sealing the vapour sampling devices after gas sample collection . 69.5 Analysis of vapour sampling devices 69.6 Storage of t
11、he test specimen between emissions tests (if required) 69.7 Cleaning the micro-scale chamber after use . 610 Calculation of vapour concentrations and specific emission rates 711 Test report . 812 Quality assurance/quality control . 9Annex A (informative) Micro-scale chamber principles .10Annex B (in
12、formative) Micro-scale chamber Example 1 .12Annex C (informative) Micro-scale chamber Example 2 .14Annex D (informative) Micro-scale chamber Example 3 .16Annex E (informative) Assessment of VOC recoveries 18Annex F (informative) Calculation of specific emission rates from micro-scale chamber air con
13、centration .19Bibliography .21BS ISO 12219-3:2012ISO 12219-3:2012(E)ForewordISO (the International Organization for Standardization) is a worldwide federation of national standards bodies (ISO member bodies). The work of preparing International Standards is normally carried out through ISO technical
14、 committees. Each member body interested in a subject for which a technical committee has been established has the right to be represented on that committee. International organizations, governmental and non-governmental, in liaison with ISO, also take part in the work. ISO collaborates closely with
15、 the International Electrotechnical Commission (IEC) on all matters of electrotechnical standardization.International Standards are drafted in accordance with the rules given in the ISO/IEC Directives, Part 2.The main task of technical committees is to prepare International Standards. Draft Internat
16、ional Standards adopted by the technical committees are circulated to the member bodies for voting. Publication as an International Standard requires approval by at least 75 % of the member bodies casting a vote.Attention is drawn to the possibility that some of the elements of this document may be
17、the subject of patent rights. ISO shall not be held responsible for identifying any or all such patent rights.ISO 12219-3 was prepared by Technical Committee ISO/TC 146, Air quality, Subcommittee SC 6, Indoor air, in collaboration with Technical Committee ISO/TC 22, Road vehicles.ISO 12219 consists
18、of the following parts, under the general title Interior air of road vehicles: Part 1: Whole vehicle test chamber Specification and method for the determination of volatile organic compounds in cabin interiors Part 2: Screening method for the determination of the emissions of volatile organic compou
19、nds from vehicle interior parts and materials Bag method Part 3: Screening method for the determination of the emissions of volatile organic compounds from vehicle interior parts and materials Micro-scale chamber method Part 4: Screening method for the determination of the emissions of volatile orga
20、nic compounds from vehicle interior parts and materials Small chamber methodThe following part is under preparation: Part 5: Screening method for the determination of the emissions of volatile organic compounds from vehicle interior parts and materials Static chamber methodiv ISO 2012 All rights res
21、ervedBS ISO 12219-3:2012ISO 12219-3:2012(E)IntroductionVolatile organic compounds (VOCs) are widely used in industry and may be emitted by many everyday products and materials. They have attracted attention in recent years because of their impact on indoor air quality. After homes and workplaces, pe
22、ople spend a lot of time in their vehicles. It is important to determine the material emissions of interior parts and to reduce them to an acceptable level, if required. Therefore it is necessary to obtain comprehensive and reliable information about the types of organic compounds in the interior ai
23、r of vehicles and also their concentrations.Monitoring emissions from vehicle trim components can be performed in several ways and the approach selected depends upon the desired outcome and the material type. For example, to obtain emissions data from complete assemblies (e.g. a dashboard or seat),
24、it is necessary to employ emissions chambers or bags that have sufficient volume to house the complete assembly (typically 1 m3). Such tests may take several hours or even days to perform, depending on specified equilibration times and the requirements of the relevant test protocol.This part of ISO
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BSISO1221932012INTERIORAIROFROADVEHICLESSCREENINGMETHODFORTHEDETERMINATIONOFTHEEMISSIONSOFVOLATILEORGANICCOMPOUNDSFROMVEHICLEINTERIORPARTSANDMATERIALSMIPDF

链接地址:http://www.mydoc123.com/p-583812.html