1、BRITISH STANDARDBS EN 14367:2005Non controllable backflow preventer with different pressure zones Family C, type AThe European Standard EN 14367:2005 has the status of a British StandardICS 91.140.60g49g50g3g38g50g51g60g44g49g42g3g58g44g55g43g50g56g55g3g37g54g44g3g51g40g53g48g44g54g54g44g50g49g3g40g
2、59g38g40g51g55g3g36g54g3g51g40g53g48g44g55g55g40g39g3g37g60g3g38g50g51g60g53g44g42g43g55g3g47g36g58Licensed Copy: Wang Bin, na, Tue Feb 06 06:55:33 GMT+00:00 2007, Uncontrolled Copy, (c) BSIBS EN 14367:2005This British Standard was published under the authority of the Standards Policy and Strategy C
3、ommittee on 31 October 2006 BSI 2006ISBN 0 580 47599 9National forewordThis British Standard was published by BSI. It is the UK implementation of EN 14367:2005. The UK participation in its preparation was entrusted by Technical Committee B/504, Water supply, to Subcommittee B/504/14, Backflow preven
4、tion.A list of organizations represented on B/504/14 can be obtained on request to its secretary.The UK Committee would like to comment on the following:The reader is advised to take these statements of B/504 into account when applying this standard.This publication does not purport to include all t
5、he necessary provisions of a contract. Users are responsible for its correct application.Compliance with British Standard cannot confer immunity from legal obligations.1. clause 9.2.2 specifies that all measuring instruments shall have an accuracy of 2 %, but this can be too wide compared with the t
6、olerance for the temperature of the test water;2. in Figure 3 the correct orientation of the test sample on the test rig is not given, it is assumed that the inlet end of the device is to the left hand side of the figure;3. two figures have been labelled Figure 4;4. contradictory information is give
7、n in clause 9.6.2.1, it may be assumed that a certified check valve EB conforming to EN 13959 having a closing pressure of 0,5 KPa will take precedence over any other check valve.Amendments issued since publicationAmd. No. Date CommentsLicensed Copy: Wang Bin, na, Tue Feb 06 06:55:33 GMT+00:00 2007,
8、 Uncontrolled Copy, (c) BSIEUROPEAN STANDARDNORME EUROPENNEEUROPISCHE NORMEN 14367June 2005ICS 91.140.60English VersionNon controllable backflow preventer with different pressurezones - Family C, type ADisconnecteur zones de pression diffrentes noncontrlables - Famille C - type ASystemtrenner mit un
9、terschiedlichen nicht kontrollierbarenDruckzonen - Familie C, Typ AThis European Standard was approved by CEN on 3 February 2005.CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this EuropeanStandard the status of a national standard
10、 without any alteration. Up-to-date lists and bibliographical references concerning such nationalstandards may be obtained on application to the Central Secretariat or to any CEN member.This European Standard exists in three official versions (English, French, German). A version in any other languag
11、e made by translationunder the responsibility of a CEN member into its own language and notified to the Central Secretariat has the same status as the officialversions.CEN members are the national standards bodies of Austria, Belgium, Cyprus, Czech Republic, Denmark, Estonia, Finland, France,Germany
12、, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Slovakia,Slovenia, Spain, Sweden, Switzerland and United Kingdom.EUROPEAN COMMITTEE FOR STANDARDIZATIONCOMIT EUROPEN DE NORMALISATIONEUROPISCHES KOMITEE FR NORMUNGManagement Centr
13、e: rue de Stassart, 36 B-1050 Brussels 2005 CEN All rights of exploitation in any form and by any means reservedworldwide for CEN national Members.Ref. No. EN 14367:2005: ELicensed Copy: Wang Bin, na, Tue Feb 06 06:55:33 GMT+00:00 2007, Uncontrolled Copy, (c) BSIEN 14367:2005 (E) 2 Contents Page For
14、eword3 Introduction .4 1 Scope 5 2 Normative references 5 3 Terms and definitions .6 3.2 Specific use 7 4 Nominal size (denomination)7 4.1 Class a device 7 4.2 Class b device7 5 Designation 7 6 Symbolization.8 7 Physico-chemical characteristics8 7.1 Materials .8 7.2 Nature of the materials9 8 Design
15、 .9 8.1 General9 8.2 Relief valve .9 9 Characteristics and test methods10 9.1 General10 9.2 General tolerances.10 9.3 Expression of the results11 9.4 End connections11 9.5 Mechanical characteristics .11 9.6 Tightness characteristics .15 9.7 Hydraulic characteristics 18 10 Order of testing23 11 Marki
16、ng and technical documents.23 11.1 Marking .23 11.2 Technical documents 24 12 Presentation at delivery 24 Annex A (normative) Complementary test methods on backflow preventers CA class b with a plastic body25 Annex B (informative) Examples of presentation of test results28 Licensed Copy: Wang Bin, n
17、a, Tue Feb 06 06:55:33 GMT+00:00 2007, Uncontrolled Copy, (c) BSIEN 14367:2005 (E) 3 Foreword This document (EN 14367:2005) has been prepared by Technical Committee CEN/TC 164 “Water supply”, the secretariat of which is held by AFNOR. This European Standard shall be given the status of a national st
18、andard, either by publication of an identical text or by endorsement, at the latest by December 2005, and conflicting national standards shall be withdrawn at the latest by December 2005. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent ri
19、ghts. CEN and/or CENELEC shall not be held responsible for identifying any or all such patent rights. According to the CEN/CENELEC Internal Regulations, the national standards organizations of the following countries are bound to implement this European Standard: Austria, Belgium, Cyprus, Czech Repu
20、blic, Den-mark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxem-bourg, Malta, Netherlands, Norway, Poland, Portugal, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom. Licensed Copy: Wang Bin, na, Tue Feb 06 06:55:33 GMT+00:00 200
21、7, Uncontrolled Copy, (c) BSIEN 14367:2005 (E) 4 Introduction In respect of potential adverse effects on the quality of water intended for human consumption, caused by the product covered by this document: 1) This document provides no information as to whether the product may be used without restric
22、tion in any of the Member States of the EU or EFTA; 2) It should be noted that, while awaiting the adoption of verifiable European criteria, existing national regulations concerning the use and/or the characteristics of this product remain in force. Licensed Copy: Wang Bin, na, Tue Feb 06 06:55:33 G
23、MT+00:00 2007, Uncontrolled Copy, (c) BSIEN 14367:2005 (E) 5 1 Scope This document specifies the: field of application; the dimensional, the physico-chemical, the design, the hydraulic, the mechanical and the acoustic characteris-tics of non-controllable backflow preventer with different pressure zo
24、nes, family C, type A, nominal sizes DN 6 to DN 50, nominal pressure PN 10. It is applicable to: Family C, type A, class “a“ for general use: devices of class “a“ shall be capable of working: at any pressure up to 1 MPa (10 bar); with any pressure variation up to 1 MPa (10 bar); at a supply temperat
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BSEN143672005NONCONTROLLABLEBACKFLOWPREVENTERWITHDIFFERENTPRESSUREZONESFAMILYCTYPEA 不同 压力 控制 回流 PDF

链接地址:http://www.mydoc123.com/p-572389.html