BS EN 622-5-2009 Fibreboards - Specifications - Requirements for dry process boards (MDF)《纤维板 规范 干燥处理板(MDF)的要求》.pdf
《BS EN 622-5-2009 Fibreboards - Specifications - Requirements for dry process boards (MDF)《纤维板 规范 干燥处理板(MDF)的要求》.pdf》由会员分享,可在线阅读,更多相关《BS EN 622-5-2009 Fibreboards - Specifications - Requirements for dry process boards (MDF)《纤维板 规范 干燥处理板(MDF)的要求》.pdf(18页珍藏版)》请在麦多课文档分享上搜索。
1、BS EN 622-5:2009ICS 79.060.20NO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAWBRITISH STANDARDFibreboards SpecificationsPart 5: Requirements for dry processboards (MDF)Licensed Copy: Wang Bin, ISO/EXCHANGE CHINA STANDARDS, 11/08/2010 02:55, Uncontrolled Copy, (c) BSIThis British
2、 Standardwas published under theauthority of the StandardsPolicy and StrategyCommittee on 31 May2010. BSI 2010ISBN 978 0 580 62907 5Amendments/corrigenda issued since publicationDate CommentsBS EN 622-5:2009National forewordThis British Standard is the UK implementation of EN 622-5:2009. Itsupersede
3、s BS EN 622-5:2006 which is withdrawn.The UK participation in its preparation was entrusted to TechnicalCommittee B/541, Wood based panels.A list of organizations represented on this committee can be obtained onrequest to its secretary.This publication does not purport to include all the necessary p
4、rovisionsof a contract. Users are responsible for its correct application.Compliance with a British Standard cannot confer immunityfrom legal obligations.Licensed Copy: Wang Bin, ISO/EXCHANGE CHINA STANDARDS, 11/08/2010 02:55, Uncontrolled Copy, (c) BSIBS EN 622-5:2009EUROPEAN STANDARD NORME EUROPEN
5、NE EUROPISCHE NORM EN 622-5 November 2009 ICS 79.060.20 Supersedes EN 622-5:2006English Version Fibreboards - Specifications - Part 5: Requirements for dry process boards (MDF) Panneaux de fibres - Exigences - Partie 5 : Exigences pour panneaux obtenus par procd sec (MDF) Faserplatten - Anforderunge
6、n - Teil 5: Anforderungen an Platten nach dem Trockenverfahren (MDF) This European Standard was approved by CEN on 3 October 2009. CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national stand
7、ard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN Management Centre or to any CEN member. This European Standard exists in three official versions (English, French, German). A version in any other
8、language made by translation under the responsibility of a CEN member into its own language and notified to the CEN Management Centre has the same status as the official versions. CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, F
9、inland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom. EUROPEAN COMMITTEE FOR STANDARDIZATION COMIT EUROPEN DE NORMALISATION EUROPISCHE
10、S KOMITEE FR NORMUNG Management Centre: Avenue Marnix 17, B-1000 Brussels 2009 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN 622-5:2009: ELicensed Copy: Wang Bin, ISO/EXCHANGE CHINA STANDARDS, 11/08/2010 02:55, Uncontrolled Copy,
11、 (c) BSIBS EN 622-5:2009EN 622-5:2009 (E) 2 Contents Page Foreword 3 1 Scope 4 2 Normative references 4 3 Terms and definitions .5 4 Requirements .6 4.1 General 6 4.2 Requirements for non load-bearing boards, including boards for general purpose use 7 4.2.1 Requirements for boards for use in dry con
12、ditions .7 4.2.2 Requirements for boards for use in humid conditions7 4.3 Requirements for load-bearing boards .8 4.3.1 Requirements for load-bearing boards for use in dry conditions 8 4.3.2 Requirements for load-bearing boards for use in humid conditions .8 4.4 Requirements for light MDF boards for
13、 non load-bearing applications, including general purpose boards 9 4.4.1 Requirements for boards for use in dry conditions .9 4.4.2 Requirements for boards for use in humid conditions. 10 4.5 Requirements for ultra-light MDF boards for non load-bearing applications, including general purpose boards
14、. 10 4.6 Requirements for boards for use in rigid underlays in roofing and walls 11 5 Verification of compliance . 12 5.1 General . 12 5.2 External control . 12 5.3 Factory production control 12 6 Supplementary properties . 12 7 Marking 13 7.1 Boards marketed within the European Economic Area for co
15、nstruction applications. 13 7.2 Other boards . 13 Annex A (normative) Boil test according to EN 1087-1 - Modified procedure . 14 Bibliography . 15 Tables Table 1 Load duration category . 5 Table 2 Examples of load-duration assignment 6 Table 3 Requirements for general purpose boards for use in dry c
16、onditions (type MDF) 7 Table 4 Requirements for general purpose boards for use in humid conditions (type MDF.H) . 7 Table 5 Requirements for load-bearing boards for use in dry conditions (type MDF.LA) 8 Table 6 Requirements for load-bearing boards for use in humid conditions (MDF.HLS) . 9 Table 7 Re
17、quirements for light MDF boards for use in dry conditions (type L-MDF) 9 Table 8 Requirements for light MDF boards for use in humid conditions (type L.MDF.H) . 10 Table 9 Requirements for ultra-light MDF boards for use in dry conditions (type UL1-MDF) 10 Table 10 Requirements for ultra-light MDF boa
18、rds for use in dry conditions (type UL2-MDF) 11 Table 11 Requirements for use in rigid underlays in roofs and walls (type MDF.RWH) 11 Table 12 Maximum interval between test . 12 Table 13 Supplementary properties 12 Licensed Copy: Wang Bin, ISO/EXCHANGE CHINA STANDARDS, 11/08/2010 02:55, Uncontrolled
19、 Copy, (c) BSIBS EN 622-5:2009EN 622-5:2009 (E) 3 Foreword This document (EN 622-5:2009) has been prepared by Technical Committee CEN/TC 112 “Wood-based panels”, the secretariat of which is held by DIN. This European Standard shall be given the status of a national standard, either by publication of
20、 an identical text or by endorsement, at the latest by May 2010, and conflicting national standards shall be withdrawn at the latest by May 2010. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CEN and/or CENELEC shall not be held
21、 responsible for identifying any or all such patent rights. This document supersedes EN 622-5:2006. This standard is one of a series specifying requirements for fibreboards. The other parts of this series are listed in Clause 2 and in the bibliography. Compared to EN 622-5:2006 the following modific
22、ations have been made: a) Panel type MDF.RWH also intended for instantaneous or short-term load duration as a rigid underlay in roofing and walls; b) Requirement for swelling in thickness after cyclic testing changed for panel type MDF.RWH in Table 11. According to the CEN/CENELEC Internal Regulatio
23、ns, the national standards organizations of the following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlan
24、ds, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and the United Kingdom. Licensed Copy: Wang Bin, ISO/EXCHANGE CHINA STANDARDS, 11/08/2010 02:55, Uncontrolled Copy, (c) BSIBS EN 622-5:2009EN 622-5:2009 (E) 4 1 Scope This European Standard specifies the requiremen
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BSEN62252009FIBREBOARDSSPECIFICATIONSREQUIREMENTSFORDRYPROCESSBOARDSMDF 纤维板 规范 干燥 处理 MDF 要求 PDF

链接地址:http://www.mydoc123.com/p-552107.html