BS 7317-2-1990 Methods for analysis of high purity copper cathode Cu-CATH-1 - Method for determination of chromium cobalt iron nickel and zinc by discrete volume nebulization atomi.pdf
《BS 7317-2-1990 Methods for analysis of high purity copper cathode Cu-CATH-1 - Method for determination of chromium cobalt iron nickel and zinc by discrete volume nebulization atomi.pdf》由会员分享,可在线阅读,更多相关《BS 7317-2-1990 Methods for analysis of high purity copper cathode Cu-CATH-1 - Method for determination of chromium cobalt iron nickel and zinc by discrete volume nebulization atomi.pdf(10页珍藏版)》请在麦多课文档分享上搜索。
1、BRITISH STANDARD BS 7317-2:1990Methods forAnalysis of high purity copper cathodeCu-CATH-1 Part 2: Method for determination of chromium, cobalt, iron, nickel and zinc by discrete volume nebulization atomic absorption spectrophotometryUDC 669.3.015.4:543.422.062:546.47+546.72/.74+546.76BS7317-2:1990Th
2、is BritishStandard having beenprepared under the directionof the Non-ferrous Metals Standards Policy Committee, was published underthe authority of the BoardofBSI and comes intoeffecton31July1990 BSI 01-2000The following BSI references relate to the work on this standard:Committee reference NFM/34Dr
3、aft for Development DD95-2ISBN 0 580 18461 7Committees responsible for this BritishStandardThe preparation of this BritishStandard was entrusted by the Non-ferrous Metals Standards Policy Committee (NFM/-) to Technical Committee NFM/34, upon which the following bodies were represented:British Bathro
4、om CouncilBritish Cable Makers ConfederationBritish Gas plcBritish Malleable Tube Fittings AssociationBritish Non-ferrous Metals FederationBritish Valve and Actuator Manufacturers AssociationCopper Development AssociationLondon Metal ExchangeNon-ferrous Metal StockistsSociety of British Aerospace Co
5、mpanies Ltd.Transmission and Distribution Association (BEAMA Ltd.)Coopted membersThe following bodies were also represented in the drafting of the standard, through subcommittees and panels:BNF Metals Technology CentreBritish Bronze and Brass Ingot Manufacturers AssociationBureau of Analysed Samples
6、 Ltd.Copper Smelters and Refiners AssociationMinistry of DefenceAmendments issued since publicationAmd. No. Date of issue CommentsBS7317-2:1990 BSI 01-2000 iContentsPageCommittees responsible Inside front coverForeword ii1 Scope 12 Principle 13 Reagents 14 Apparatus 15 Procedure 26 Calculation and e
7、xpression of results 37 Repeatability and reproducibility 38 Test report 4Figure 1 Accessory for discrete volume nebulization 1Table 1 Calibration solutions 2Table 2 Test conditions for impurity element determinations 2Table 3 Maximum mean differences for impurity elements 3Table 4 Repeatability of
8、results 4Table 5 Reproducibility of results 4Publications referred to Inside back coverBS7317-2:1990ii BSI 01-2000ForewordBS 7317 has been prepared under the direction of the Non-ferrous Metals Standards Policy Committee. It describes methods for the determination of impurity elements in high purity
9、 copper cathode designated Cu-CATH-1, each method being published as a separate Part. The methods are based on those previously issued in the Draft for Development series DD95-1 to DD95-7. The information and experience gained from the practical application of DD95 have been taken into account in th
10、e methods in BS7317.This Part of BS7317 supersedes DD95-2:1984, which is withdrawn. It is one of a series of methods in BS7317, the others being as follows: Part 1: Method for determination of cadmium, manganese and silver (screening procedure for chromium, cobalt, iron, nickel and zinc) by atomic a
11、bsorption spectrophotometry; Part 3: Method for determination of antimony, arsenic, bismuth, selenium, tellurium and tin by hydride generation and atomic absorption spectrophotometry; Part 4: Method for determination of antimony, arsenic, bismuth, lead, selenium, tellurium and tin by electrothermal
12、atomization atomic absorption spectrophotometry; Part 5: Method for determination of sulphur by hydrogen sulphide evolution and spectrophotometry; Part 6: Method for determination of phosphorus and silicon by spectrophotometry; Part 7: Method for determination of lead by lanthanum hydroxide separati
13、on and atomic absorption spectrophotometry.The atomic absorption spectrophotometric procedures in Parts1 and2 are complementary. A sample solution concentration found to be satisfactory for nebulizers in standard atomic absorptiometers was20g/L. At this concentration the precision obtainable, using
14、the method described in Part1, is only sufficient to allow the determination of cadmium, manganese and silver. Results would be obtained for chromium, cobalt, iron, nickel and zinc that would prove useful in detecting impurities grossly in excess of the requirements for chemical compositions specifi
15、ed in BS6017 for Cu-CATH-1 and would give a guide to the levels to be determined by this Part.The discrete volume nebulization procedure in this Part was developed to enable a high equivalent sample solution concentration of100g/L to be used without nebulizer blockage. The method involves no chemica
16、l separation, which can give rise to contamination problems, and the extra sensitivity obtained enables the impurities to be determined to an adequate accuracy for the requirements for chemical composition specified in BS6017 for Cu-CATH-1.Parts1 and2 essentially cover the same impurities. Part4 cov
17、ers the electrothermal atomization atomic absorption spectrophotometric method and is recommended where the facility is available. Parts1,2,3 and7 are included for use where the electrothermal atomization equipment is not available.A British Standard does not purport to include all the necessary pro
18、visions of a contract. Users of British Standards are responsible for their correct application.Compliance with a British Standard does not of itself confer immunity from legal obligations.Summary of pagesThis document comprises a front cover, an inside front cover, pagesi andii, pages1 to4, an insi
19、de back cover and a back cover.This standard has been updated (see copyright date) and may have had amendments incorporated. This will be indicated in the amendment table on the inside front cover.BS7317-2:1990 BSI 01-2000 11 ScopeThis Part of BS7317 describes a method for the determination of the a
20、ctual amounts of the impurity elements chromium, cobalt, iron, nickel and zinc present in high purity copper cathode (designatedCu-CATH-1), by discrete volume nebulization atomic absorption spectrophotometry.NOTE 1This method is intended to be used for analysis samples prepared by the procedures giv
21、en in BS6017. These samples should be significantly oxygen free. If this method is used for other materials, such as copper wire rod produced from high purity cathodes, where oxygen can be introduced during processing, then low results may be obtained for the chromium and iron contents.NOTE 2The tit
22、les of the publications referred to in this Part of BS7317 are listed on the inside back cover.2 PrincipleThe sample of Cu-CATH-1 is dissolved in the minimum of nitric acid and diluted to volume. The impurity elements are then determined using an atomic absorption spectrophotometer, into which a sma
23、ll volume of the concentrated sample solution is injected by means of a discrete volume nebulization (DVN) system.3 Reagents3.1 GeneralDuring the analysis, use only reagents of recognized analytical quality or of higher purity and only distilled water, deionized water or water of equivalent purity,
24、that has no detectable levels of the particular elements to be determined.NOTEUnless otherwise stated, all solutions are aqueous solutions.3.2 Nitric acid, 1.42g/mL,50%V/V solution.3.3 Copper1), a certified reference material of a minimum of99.999% copper, containing less than0.54g/g of each of the
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BS731721990METHODSFORANALYSISOFHIGHPURITYCOPPERCATHODECUCATH1METHODFORDETERMINATIONOFCHROMIUMCOBALTIRONNICKELANDZINCBYDISCRETEVOLUMENEBULIZATIONATOMIPDF

链接地址:http://www.mydoc123.com/p-546691.html