BS 6200-3 26 2-1991 Sampling and analysis of iron steel and other ferrous metals - Methods of analysis - Determination of silicon - Acid-resisting high silicon iron gravimetric met.pdf
《BS 6200-3 26 2-1991 Sampling and analysis of iron steel and other ferrous metals - Methods of analysis - Determination of silicon - Acid-resisting high silicon iron gravimetric met.pdf》由会员分享,可在线阅读,更多相关《BS 6200-3 26 2-1991 Sampling and analysis of iron steel and other ferrous metals - Methods of analysis - Determination of silicon - Acid-resisting high silicon iron gravimetric met.pdf(8页珍藏版)》请在麦多课文档分享上搜索。
1、BRITISH STANDARD BS 6200-3.26.2: 1991 Sampling and analysis of iron, steel and other ferrous metals Part3: Methods of analysis Section3.26 Determination of silicon Subsection3.26.2 Acid-resisting high silicon iron: gravimetric methodBS6200-3.26.2:1991 This British Standard, having been prepared unde
2、r the directionof the Iron and Steel Standards Policy Committee, waspublished under the authorityof the Standards Board and comes into effect on 29 November1991 BSI09-1999 The following BSI references relate to the work on this standard: Committee reference ISM/18 Draft for comment91/35216 DC ISBN 0
3、 580 19943 6 Committees responsible for this British Standard The preparation of this British Standard was entrusted by the Iron and Steel Standards Policy Committee (ISM/-) to Technical Committee ISM/18, upon which the following bodies were represented: BCIRA British Steel Industry Department of Tr
4、ade and Industry (Laboratory of the Government Chemist) Ferro Alloys and Metals Producers Association Ministry of Defence Amendments issued since publication Amd. No. Date CommentsBS6200-3.26.2:1991 BSI 09-1999 i Contents Page Committees responsible Inside front cover Foreword ii 1 Scope 1 2 Princip
5、le 1 3 Reagents 1 4 Apparatus 1 5 Sampling 1 6 Procedure 1 7 Calculation and expression of results 2 8 Test report 2 Publication(s) referred to Inside back coverBS6200-3.26.2:1991 ii BSI 09-1999 Foreword This Subsection of BS6200 has been prepared under the direction of the Iron and Steel Standards
6、Policy Committee and supersedes method2 for the determination of silicon in BSI Handbook No.19, to which it is technically equivalent. BS6200 is a multipart British Standard, covering all aspects of the sampling and analysis of iron, steel and other ferrous metals. A list of contents, together with
7、general information, is given in Part1. A British Standard does not purport to include all the necessary provisions of a contract. Users of British Standards are responsible for their correct application. Compliance with a British Standard does not of itself confer immunity from legal obligations. S
8、ummary of pages This document comprises a front cover, an inside front cover, pagesi andii, pages1 and 2, an inside back cover and a back cover. This standard has been updated (see copyright date) and may have had amendments incorporated. This will be indicated in the amendment table on the inside f
9、ront cover.BS6200-3.26.2:1991 BSI 09-1999 1 1 Scope This Subsection of BS6200 describes a gravimetric method for the determination of silicon in acid-resisting high silicon irons. The method is applicable to silicon contents from10% (m/m) to20% (m/m). NOTEThe titles of the publications referred to i
10、n this Subsection of BS6200 are listed on the inside back cover. 2 Principle The test portion is dissolved in a mixture of ammonium chloride, hydrobromic acid and bromine. After evaporation to dryness and extraction in acid, the precipitated silica is filtered off and the filtrate fumed with perchlo
11、ric acid, redissolved and filtered. The combined silica precipitates are ignited in a platinum vessel and silicon calculated from loss in weight with hydrofluoric acid. 3 Reagents During the analysis, use only reagents of recognized analytical grade and only grade3water as specified in BS3978. WARNI
12、NG. Suitable safety precautions should be taken during reagent preparation and use of bromine, hydrobromic acid and hydrofluoric acid, which are all highly irritant and corrosive. Perchloric acid vapour may cause explosions in the presence of nitrous fumes or organic material in general. 3.1 Ammoniu
13、m chloride 3.2 Bromine-hydrobromic acid. To100mL of hydrobromic acid, density =1.46g/mL to1.49 g/mL, add10mL of bromine and mix. 3.3 Hydrochloric acid, =1.16g/mL to1.18g/mL. 3.4 Hydrochloric acid, diluted1+4. To500mL of water, add200mL of hydrochloric acid(3.3), mix, dilute to1L and mix. 3.5 Hydrofl
14、uoric acid,40% (m/m) 3.6 Nitric acid, =1.42g/mL. 3.7 Perchloric acid, =1.54g/mL. 3.8 Sodium carbonate, anhydrous. 3.9 Sulfuric acid, =1.84g/mL. 3.10 Sulfuric acid, diluted1+3. To70mL of water add cautiously25mL of sulfuric acid(3.9), mix, cool, dilute to100mL and mix. 4 Apparatus 4.1 Ordinary labora
15、tory apparatus 4.2 Platinum vessel 4.3 Muffle furnace, operating at1100 C. 5 Sampling Carry out sampling in accordance with BS1837. NOTEBS6200-2, which will supersede BS1837, is currently in preparation. On its publication this Subsection will be amended to include sampling in accordance with BS6200
16、-2. 6 Procedure 6.1 Test portion For materials with up to15% (m/m) silicon, weigh to the nearest0.001g a test portion of1.0g. For higher silicon contents weigh a0.5g test portion. 6.2 Blank test In parallel with the determination and following the same procedure carry out a blank test, using the sam
17、e quantities of all reagents. 6.3 Determination 6.3.1 Preparation of the test solution Place the test portion in a250mL squat beaker. Add1g of ammonium chloride(3.1) and20mL of bromine-hydrobromic acid mixture(3.2), cover the beaker and allow to stand for30min. Heat on a steam bath until any remaini
18、ng sample has dissolved, evaporate to dryness and continue heating for1h. Add20mL of hydrochloric acid(3.3) and heat on the steam bath until soluble salts are dissolved. Dilute with100mL of cold water. 6.3.2 First separation of silica Filter through a paper-pulp pad into a600mL squat beaker, rinse t
19、he250mL beaker and cover with small washes of hot hydrochloric acid(3.4) and remove adherent particles of precipitate with the aid of a rubber-tipped glass rod. Wash the filter alternately with hot hydrochloric acid(3.4) and cold water, until freed from iron salts. Remove water from the pad using li
20、ght suction and then transfer the filter pad and silica to the platinum vessel(4.2), using small pieces of ashless filter paper, and reserve. 6.3.3 Recovery of soluble silica 6.3.3.1 Cover the600mL beaker, evaporate the filtrate to dryness, cool and add20mL of water. Add nitric acid(3.6) dropwise to
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BS620032621991SAMPLINGANDANALYSISOFIRONSTEELANDOTHERFERROUSMETALSMETHODSOFANALYSISDETERMINATIONOFSILICONACIDRESISTINGHIGHSILICONIRONGRAVIMETRICMETPDF

链接地址:http://www.mydoc123.com/p-545837.html