BS 5254-1976 Specification for polypropylene waste pipe and fittings (external diameter 34 6 mm 41 0 mm and 54 1 mm)《聚丙烯污水管及配件(外径为34 6mm、41 0mm、54 1mm)规范》.pdf
《BS 5254-1976 Specification for polypropylene waste pipe and fittings (external diameter 34 6 mm 41 0 mm and 54 1 mm)《聚丙烯污水管及配件(外径为34 6mm、41 0mm、54 1mm)规范》.pdf》由会员分享,可在线阅读,更多相关《BS 5254-1976 Specification for polypropylene waste pipe and fittings (external diameter 34 6 mm 41 0 mm and 54 1 mm)《聚丙烯污水管及配件(外径为34 6mm、41 0mm、54 1mm)规范》.pdf(18页珍藏版)》请在麦多课文档分享上搜索。
1、BRITISH STANDARD BS5254:1976 Incorporating Amendment Nos.1 and2 Specification for Polypropylene waste pipe and fittings (external diameter34.6mm,41.0mm and54.1mm) UDC621.643.29:678.742.3462:696.122:628.21BS5254:1976 This British Standard, having been approved by the Plastics Industry Standards Commi
2、ttee, was published under the authorityof the Executive Boardon 30 January1976 BSI06-1999 The following BSI references relate to the work on this standard: Committee references PLC/9 andPLC/9/4 Draft for comment71/52878 ISBN 0 580 08845 6 Co-operating organizations The Plastics Industry Standards Co
3、mmittee, under whose supervision this British Standard was prepared, consists of representatives from the following Government departments and industrial organizations: The Government departments and scientific and industrial organizations marked with an asterisk in the above list, together with the
4、 following, were directly represented on the committee entrusted with the preparation of this British Standard: British Plastics Federation* Engineering Equipment Users Association* British Resin Manufacturers Association Ministry of Defence* Chemical Industries Association Ltd.* Plastics Institute
5、Department of the Environment, Building Post Office Research Establishment* Royal Institute of British Architects* Department of Industry Chemicals and Royal Institute of Public Health and Hygiene Textiles Rubber and Plastics Research Association of Electrical and Electronic Insulation Association G
6、reat Britain Electrical Installation Equipment Society of Motor Manufacturers and Traders Manufacturers Association Ltd.* Electrical Research Association Association of Public Health Inspectors Institution of Water Engineers British Chemical and Dyestuffs Traders Lloyds Register of Shipping Associat
7、ion Ltd. Ministry of Agriculture, Fisheries and Food British Gas Corporation National Association of Plumbing, Heating British Precast Concrete Federation and Mechanical Service Contractors British Rubber Manufacturers Association Ltd. National Federation of Builders and British Steel Industry Plumb
8、ers Merchants Copper Tube Fittings Manufacturers National Water Council Association Oil Companies Materials Association Department of the Environment Pitch Fibre Pipe Association Gas List Tube Association Royal Institution of Chartered Surveyors Greater London Council Royal Society of Health Institu
9、te of Plumbing Society of Builders Merchants Institution of Civil Engineers Water Companies Association Institution of Municipal Engineers Water Research Association Institution of Public Health Engineers Amendments issued since publication Amd. No. Date of issue Comments 3588 May1981 4438 December1
10、983 Indicated by a sideline in the marginBS5254:1976 BSI 06-1999 i Contents Page Co-operating organizations Inside front cover Foreword ii 1 Scope 1 2 References 1 3 Material 1 4 Appearance 1 5 Pipe dimensions 1 6 Fitting dimensions 1 7 Length of pipe 1 8 Marking 1 9 Heat reversion requirement for p
11、ipe 2 10 Impact requirement for pipe 2 11 Hydrostatic pressure requirement 2 12 Stress relief requirement 2 13 Elevated temperature cycling requirement 2 14 Joint systems 3 Appendix A Heat reversion test for pipe 4 Appendix B Impact test for pipe 4 Appendix C Hydrostatic pressure test 4 Appendix D S
12、tress relief test 5 Appendix E Elevated temperature cycling test 5 Figure 1 Socket dimensions for fittings 6 Figure 1d Positions for measurement of snap cap wall thicknesses 7 Figure 2 Bends and equal branches 7 Figure 3 Unequal branches 8 Figure 4 Reducers 8 Figure 5 Straight coupling (with or with
13、out register) 9 Figure 6 Socket plugs (with or without access cap) 9 Figure 7 Adaptors 9 Figure 8 Typical caulking bush 9 Figure 9 Suitable type of impact testing machine 10 Figure 10 Typical test installation for elevated temperature cycling test 11 Table 1 Dimensions of polypropylene pipe and fitt
14、ings 3 Table 2 Minimum dimensions of joint sockets 3 Publications referred to 12BS5254:1976 ii BSI 06-1999 Foreword This British Standard has been prepared under the authority of the Plastics Industry Standards Committee. Requirements are given for waste pipe and fittings manufactured from polypropy
15、lene intended to convey normal domestic effluent. Detailed material requirements are not specified but there is a requirement to be able to withstand the long term effects of the intermittent discharge of hot water. The outside diameters of pipes specified in this standard are based upon superseded
16、copper pipe sizes in accordance with BS659 (generally copper tubes are now manufactured to metric sizes in accordance with Part1 “Copper tubes for water, gas and sanitation” of BS2871 “Copper and copper alloys, tubes”) and some local authorities in the UK may deem them to be unacceptable. Attention
17、is drawn to BS5255 “Plastics waste pipe and fittings”, which specifies waste pipe systems with bore dimensions based on the clear bore principle and manufactured from ABS, modified UPVC, polypropylene and high density polyethylene. Notwithstanding the foregoing, the minimum bore of pipes and fitting
18、s covered by this standard is in excess of the minimum bore of the outlets of associated plastic traps in accordance with BS3943 “Plastics waste traps” which discharge into the waste pipes covered by this standard. It is the intention to continue studies towards the introduction of a fully rational
19、range of pipe in line with those being considered internationally by Technical Committee138 of the International Organization for Standardization (ISO). The various jointing methods in use preclude at present the standardization of the lengths and configurations of fittings. Because the length of wa
20、ste pipe from the sanitary apparatus is subjected to waste water at its highest temperature and may also be flowing full-bore, the elevated temperature cycling test for waste pipe and fittings is carried out using hotter water than the similar test for soil pipe and fittings. Certification. It is st
21、rongly recommended that in view of the nature of this specification, manufacturers and purchasers should make use of the certification facilities described on the inside back cover of this standard. A British Standard does not purport to include all the necessary provisions of a contract. Users of B
22、ritish Standards are responsible for their correct application. Compliance with a British Standard does not of itself confer immunity from legal obligations. Summary of pages This document comprises a front cover, an inside front cover, pagesi and ii, pages1 to 12, an inside back cover and a back co
23、ver. This standard has been updated (see copyright date) and may have had amendments incorporated. This will be indicated in the amendment table on the inside front cover.BS5254:1976 BSI 06-1999 1 1 Scope This British Standard specifies requirements for polypropylene waste pipe and fittings intended
24、 to convey normal domestic effluent. NOTEIf it is intended to use this pipe and these fittings other than in installations for normal domestic effluent it is essential to seek expert advice from the manufacturer on the suitability for the particular application. If the waste pipe is to be installed
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BS52541976SPECIFICATIONFORPOLYPROPYLENEWASTEPIPEANDFITTINGSEXTERNALDIAMETER346MM410MMAND541MM 聚丙烯 污水

链接地址:http://www.mydoc123.com/p-544980.html