BS 1042-2 2-1983 Measurement of fluid flow in closed conduits - Velocity area methods - Method of measurement of velocity at one point of a conduit of circular cross section《封闭管道内液.pdf
《BS 1042-2 2-1983 Measurement of fluid flow in closed conduits - Velocity area methods - Method of measurement of velocity at one point of a conduit of circular cross section《封闭管道内液.pdf》由会员分享,可在线阅读,更多相关《BS 1042-2 2-1983 Measurement of fluid flow in closed conduits - Velocity area methods - Method of measurement of velocity at one point of a conduit of circular cross section《封闭管道内液.pdf(20页珍藏版)》请在麦多课文档分享上搜索。
1、BRITISH STANDARD BS 1042-2.2: 1983 ISO 7145:1982 Measurement of fluid flow in closed conduits Part 2: Velocity area methods Section 2.2 Method of measurement of velocity at one point of a conduit of circular cross section ISO title: Determination of flowrate of fluids in closed conduits of circular
2、cross-section Method of velocity measurement at one point of the cross-section UDC 532.542:532.574:621.643.2-462.311BS1042-2.2:1983 This British Standard, having been prepared under the directionof the Industrial-process Measurement and Control Standards Committee, was published under the authority
3、ofthe Board of BSI and comes intoeffect on 31 August 1983 BSI 07-1999 The following BSI references relate to the work on this standard: Committee reference PCL/2 Draft for comment 81/25553 DC ISBN 0 580 13383 4 Committees responsible for this British Standard The preparation of this British Standard
4、 was entrusted by the Industrial-process Measurement and Control Standards Committee (PCL/-) to Technical Committee PCL/2 upon which the following bodies were represented: British Compressed Air Society British Gas Corporation British Industrial Measuring and Control Apparatus Manufacturers Associat
5、ion (BEAMA) Department of Energy (Gas Standards) Department of Industry (National Engineering Laboratory) Department of Trade (Consumer Safety Unit, CS Division) Department of Trade (National Weights and Measures Laboratory) Electricity Supply Industry in England and Wales Energy Industries Council
6、Institute of Measurement and Control Institute of Petroleum Institute of Trading Standards Administration Institution of Gas Engineers National Water Council Society of Chemical Industry United Kingdom Atomic Energy Authority Coopted member The following bodies were also represented in the drafting
7、of the standard, through subcommittees and panels: Fan Manufacturers Association Hevac Association National Coal Board Scientific Instrument Manufacturers Association (BEAMA) Amendments issued since publication Amd. No. Date of issue CommentsBS1042-2.2:1983 BSI 07-1999 i Contents Page Committees res
8、ponsible Inside front cover National foreword ii 1 Scope and field of application 1 2 Symbols and definitions 1 3 Principle 3 4 Procedure 4 5 Uncertainties of measurement 6 Annex A Determination of the transverse velocity gradient at the point of mean axial velocity 11 Annex B Example of calculation
9、 of the uncertainty of a flow measurement when the primary device is placed at the point of mean axial velocity 11 Annex C Example of calculation of the uncertainty of a flow measurement when the primary device is placed on the axis of the conduit 12 Publications referred to Inside back coverBS1042-
10、2.2:1983 ii BSI 07-1999 National foreword This British Standard has been prepared under the direction of the Industrial-process Measurement and Control Standards Committee and is identical with ISO7145:1982 “Determination of flowrate of fluids in closed conduits of circular cross-section Method of v
11、elocity measurement at one point of the cross-section”, published by the International Organization for Standardization (ISO). Terminology and conventions. The text of the international standard has been approved as suitable for publication as a British Standard without deviation. Some terminology a
12、nd certain conventions are not identical with those used in British Standards; attention is drawn especially to the following. The comma has been used as a decimal marker. In British Standards it is current practice to use a full point on the baseline as the decimal marker. Wherever the words “Inter
13、national Standard” appear, referring to this standard, they should be read as “British Standard”. The Technical Committee has reviewed the provisions of ISO3354 and ISO3966, to which reference is made in the text and for which there are no corresponding British Standards, and has decided that they a
14、re acceptable for use in conjunction with this standard. A British Standard does not purport to include all the necessary provisions of a contract. Users of British Standards are responsible for their correct application. Compliance with a British Standard does not of itself confer immunity from leg
15、al obligations. Cross-references International standard Corresponding British Standard ISO 4006:1977 BS 5875:1980 Glossary of terms and symbols for measurement of fluid flow in closed conduits (Identical) ISO 5168:1978 BS 5844:1980 Methods of measurement of fluid flow: estimation of uncertainty of a
16、 flowrate measurement (Identical) Summary of pages This document comprises a front cover, an inside front cover, pages i and ii, pages1to14, an inside back cover and a back cover. This standard has been updated (see copyright date) and may have had amendments incorporated. This will be indicated in
17、the amendment table on the inside front cover.BS1042-2.2:1983 BSI 07-1999 1 1 Scope and field of application 1.1 Scope This International Standard specifies a method for the determination of the volume rate of flow of a single phase fluid of a substantially constant density (Mach number u 0,25) unde
18、r steady fully developed flow conditions in a closed conduit of circular cross-section running full by measurement of the flow velocity in a single point. The method provides for the possibility of placing the primary velocity measuring device either at the point where it is assumed the mean axial v
19、elocity prevails, i.e. at a distance of0,242 R from the wall of the conduit (R being the radius of the conduit), or on the axis of the conduit. If there are doubts about the symmetry of the flow it is advisable to use at least two measuring points located symmetrically on one circumference at the di
20、stance from the wall specified above. 1.2 Field of application The method specified in this International Standard does not apply unless the following conditions have been fulfilled: a) The conduit shall have a straight length sufficiently long so that, in the measuring section, a distribution of ve
21、locities corresponding to fully developed turbulent flow can be observed (see2.3.5). Hydraulic resistance coefficient 2 of the conduit should not exceed0,06. b) The flow must be turbulent and the Reynolds number, Re D 9 should exceed or be equal to the following values: When the velocity is measured
22、 on the conduit axis, the flow should be in fully rough turbulent regime (see2.3.6). The Reynolds number, Re D , should then exceed or be equal to: c) The experimental data on which this International Standard is based principally relate to conduits of diameter equal to or greater than300mm, but the
23、re is every reason to believe that the method can be applied to conduits of smaller diameter. d) In any point of the measuring cross-section, the angle between the direction of local velocity and the axis should not exceed5 . This condition can be verified either with the probe used for the measurem
24、ents, if the design permits this, or with a different type of probe. It can be assumed that if the condition required is verified for a given flow q, then this condition is also met within the range q/3 to3q. 1.3 Accuracy of the method As a guide, it can be considered that determination of flow from
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BS1042221983MEASUREMENTOFFLUIDFLOWINCLOSEDCONDUITSVELOCITYAREAMETHODSMETHODOFMEASUREMENTOFVELOCITYATONEPOINTOFACONDUITOFCIRCULARCROSSSECTION

链接地址:http://www.mydoc123.com/p-542597.html