《ASTM F3207-2017 Standard Guide for in vivo Evaluation of Rabbit Lumbar Intertransverse Process Spinal Fusion Model《兔腰椎间横突间脊柱融合模型体内评估的标准指南》.pdf》由会员分享,可在线阅读,更多相关《ASTM F3207-2017 Standard Guide for in vivo Evaluation of Rabbit Lumbar Intertransverse Process Spinal Fusion Model《兔腰椎间横突间脊柱融合模型体内评估的标准指南》.pdf(16页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: F3207 17Standard Guide forin vivo Evaluation of Rabbit Lumbar Intertransverse ProcessSpinal Fusion Model1This standard is issued under the fixed designation F3207; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the ye
2、ar of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 Historically, the single-level rabbit posterolateral, orintertransverse, lumbar spine fusion model was developed
3、 andreported on by Dr. Scott Boden, et. al. (Emory Spine Center forOrthopedics) and the model has been proposed as a non-clinical model which may be used to replicate clinically-relevant fusion rates for iliac crest autograft in the posterolat-eral spine (1, 2).2This model is used routinely in submi
4、ssionsto regulatory bodies for the purpose of evaluating the potentialefficacy of bone void filler materials as compared to othermaterials or iliac crest autograft to effect spinal posterolateralfusion. The use of this standards recommendations as part ofa regulatory submission does not provide any
5、guarantee ofregulatory clearance and should be considered as a part of thedata provided for regulatory submission.1.2 This guide covers general guidelines to evaluate theeffectiveness of products intended to cause and/or promotebone formation in the lumbar intertransverse process spinalfusion model
6、in vivo. This guide is applicable to products thatmay be composed of one or more of the following components:natural biomaterials (such as demineralized bone), and syn-thetic biomaterials (such as calcium sulfate, glycerol, andreverse phase polymeric compounds) that act as additives,fillers, and/or
7、excipients (radioprotective agents, preservatives,and/or handling agents). It should not be assumed that productsevaluated favorably using this guidance will form bone whenused in a clinical setting. The primary purpose of this guide isto facilitate the equitable comparison of bone void fillers and/
8、orautograft extender products in vivo. The purpose of this guideis not to exclude other established methods.1.3 The values stated in SI units are to be regarded asstandard. No other units of measurement are included in thisstandard.1.4 This standard does not purport to address all of thesafety conce
9、rns, if any, associated with the use of bone voidfillers. It is the responsibility of the user of this standard toestablish appropriate safety and health practices involved inthe development of said products in accordance with appli-cable regulatory guidance documents and in implementing thisguide t
10、o evaluate the bone-forming/promoting capabilities ofthe product.1.5 This standard does not purport to address the require-ments under 21 CFR Part 58 concerning Good LaboratoryPractices or international standard counterpart OECD Prin-ciples of Good Laboratory Practice (GLP). It is the responsi-bilit
11、y of the sponsor of the study to understand the require-ments for conduct of animal studies whereby the data may beused to support premarket applications, including require-ments for personnel, protocol content, record retention andanimal husbandry.1.6 This international standard was developed in ac
12、cor-dance with internationally recognized principles on standard-ization established in the Decision on Principles for theDevelopment of International Standards, Guides and Recom-mendations issued by the World Trade Organization TechnicalBarriers to Trade (TBT) Committee.2. Referenced Documents2.1 A
13、STM Standards:3E122 Practice for Calculating Sample Size to Estimate, WithSpecified Precision, the Average for a Characteristic of aLot or ProcessE1402 Guide for Sampling DesignE1488 Guide for Statistical Procedures to Use in Developingand Applying Test MethodsF2529 Guide forin vivo Evaluation of Os
14、teoinductive Poten-tial for Materials Containing Demineralized Bone (DBM)F2884 Guide for Pre-clinical in vivo Evaluation of SpinalFusion2.2 Federal Documents:421 CFR 58 Good Laboratory Practice for Nonclinical Labo-ratory Studies1This guide is under the jurisdiction of ASTM Committee F04 on Medical
15、andSurgical Materials and Devices and is the direct responsibility of SubcommitteeF04.44 on Assessment for TEMPs.Current edition approved June 1, 2017. Published July 2017. DOI: 10.1520/F3207-172The boldface numbers in parentheses refer to the list of references at the end ofthis standard.3For refer
16、enced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.4Available from U.S. Food and Drug Administration (FDA), 10903 NewHamps
17、hire Ave., Silver Spring, MD 20993, http:/www.fda.gov.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United StatesThis international standard was developed in accordance with internationally recognized principles on standardization established in
18、the Decision on Principles for theDevelopment of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.12.3 AAMI/ISO Documents:5ISO 10993-6 Third edition 2016-12-01 Biological evalua-tion of medical devices Part 6: Test
19、s for local effectsafter implantation3. Terminology3.1 Definitions:3.1.1 biomechanical fusion, nthe increased strengthand/or stiffness and reduced ROM of a spinal unit as comparedto that measured before surgical intervention.3.1.2 biomechanical properties, nas used in thisdocument, evaluation of the
20、 operative functional spinal unitmultidirectional range of motion (ROM: Lateral bending,Flexion Extension and Axial Rotation) properties undernon-destructive conditions, tensile stiffness and ultimate load.3.1.3 fusion, na multifactorial outcome which can becharacterized in terms of the radiographic
21、, biomechanical andhistological results of the intended spinal arthrodesis proce-dure.3.1.4 histological evidence of fusion, nbased on lightmicroscopy of newly formed and remodeled bone spanning theintertransverse region, with contiguous osseous connectivityobserved between the adjacent transverse p
22、rocesses. Assess-ment rationale must be justified.3.1.5 manual palpation, na method for evaluating spinalfusion status by estimating the stiffness of the operative motionsegment and adjacent superior motion segment by the appli-cation of multidirectional loads in lateral bending and flexion-extensio
23、n using the hands.3.1.6 micro-computed tomographic (micro-CT) fusion,ntomographic fusion is based on interpretation of themicro-CT images, with fusion success based on the three-dimensional appearance of contiguous bone from transverseprocess to transverse process (i.e. bridging bone).3.1.7 non-unio
24、n, na multifactorial outcome which can becharacterized in terms of the radiographic, biomechanical andhistological results indicating a lack of trabecular or corticalbone spanning the intertransverse region, without contiguousosseous connectivity observed between the adjacent transverseprocesses.3.1
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMF32072017STANDARDGUIDEFORINVIVOEVALUATIONOFRABBITLUMBARINTERTRANSVERSEPROCESSSPINALFUSIONMODEL 腰椎

链接地址:http://www.mydoc123.com/p-540147.html