ASTM F2990-2012 Standard Test Method for Commercial Coffee Brewers《商业咖啡啤酒的标准试验方法》.pdf
《ASTM F2990-2012 Standard Test Method for Commercial Coffee Brewers《商业咖啡啤酒的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM F2990-2012 Standard Test Method for Commercial Coffee Brewers《商业咖啡啤酒的标准试验方法》.pdf(10页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: F2990 12Standard Test Method forCommercial Coffee Brewers1This standard is issued under the fixed designation F2990; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses in
2、dicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the evaluation of the energyconsumption, brewing, and holding performance of commer-cial coffee brewing machines (here after referred t
3、o as coffeebrewers) used in commercial and institutional facilities. Theoperator can use this evaluation to select a coffee brewer andcharacterize its energy use and performance. This test methoddoes not cover residential coffee brewers, “urn” coffee brewers(Type III), or espresso machines.1.2 This
4、test method applies to single cup (Type I) and batch(Type II) coffee brewers. The coffee brewer will be tested forthe following (where applicable):1.2.1 Maximum energy input rate,1.2.2 Heavy use brewing energy consumption,1.2.3 Production capacity,1.2.4 “Ready-to-Brew” (Standby/Idle) energy rate, an
5、d1.2.5 “Energy Save Mode” (Low power) energy rate.1.3 The values stated in inch-pound units are to be regardedas standard. The values given in parentheses are mathematicalconversions to SI units that are provided for information onlyand are not considered standard.1.4 This standard does not purport
6、to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2F2988 S
7、pecification for Commercial Coffee Brewers2.2 ASHRAE Standard:ASHRAE Guideline 21986 (RA90) Engineering Analysisof Experimental Data3. Terminology3.1 Definitions:3.1.1 coffee brewer, ncommercial appliances designed toheat water and brew coffee.NOTE 1Cold water is poured into a separate chamber (manu
8、ally orautomatically), which is then heated up to just below the boiling point, anddirected through the filter. This process is also called automatic drip-brew.3.2 Definitions of Terms Specific to This Standard:3.2.1 brew cycle, nthe total time required to dispense asingle cup (Type I) or batch (Typ
9、e II) of coffee, starting withthe initiation of a brew event by the user, and including thetime needed for the machine to recover to a “ready to brew”state.3.2.2 brew event, nthe sequence of brewing a single cup(Type I) or batch (Type II) of coffee, starting with initiation bythe user, and including
10、 the time for the remaining water to dripthrough the filter.3.2.3 brew energy, nenergy consumed by coffee brewerduring a brew cycle.3.2.4 warmer energy, nthe energy consumed by the platewarmer while maintaining the delivered brew volume atserving temperature.NOTE 2Warmers may not be an applicable fe
11、ature of single servingType I machines.3.2.5 ready-to-brew (standby/idle) energy, nenergy re-quired by the coffee brewer to maintain “ready to brew”conditions including energy required to keep the reservoir tankat the brew set temperature.3.2.6 energy save mode, nan optional low power mode(different
12、 from the ready-to-brew state) that is designed by themanufacturer to use less energy while the coffee brewer stillremains “on.”NOTE 3Energy Save Modes are typically specified by the manufac-turer and outlined in the user manual. Some examples may include anautomatic reduction of tank holding temper
13、ature (for example, 140) orburner temperature after a certain period of machine un-use. The manualturning off of accessories is not considered to be an Energy Save Modeunless specified by the manufacturer.3.2.7 production capacity, ncalculated maximum volumeof coffee that can potentially be brewed i
14、n one full hour andexpressed in gal/h (L/h).1This test method is under the jurisdiction of ASTM Committee F26 on FoodService Equipment and is the direct responsibility of Subcommittee F26.06 onProductivity and Energy Protocol.Current edition approved Dec. 1, 2012. Published February 2013. DOI: 10.15
15、20/F2990-12.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.Copyright ASTM International, 100 Barr Harbor Dri
16、ve, PO Box C700, West Conshohocken, PA 19428-2959. United States13.2.8 brew volume, nthe substantive beverage portiondelivered during a single brew event, and specified in fluidounces or gallons (millilitres or litres).3.2.9 serving temperature, nthe temperature of the bever-age delivered from a bre
17、wing machine, measured at thedispensing outlet, and expressed in degrees Farenheit (degreesCelsius).3.2.10 holding temperature, nthe measured average inter-nal temperature of a volume of dispensed beverage as main-tained by the plate warmers and expressed in degrees Farenheit(degrees Celsius).3.2.11
18、 recovery time, nthe time required for the machineto return to brew set temperature (“ready to brew state”) aftera completed brew event.4. Summary of Test Method4.1 All testing is conducted using default factory settings forbrewers that feature programmable settings. If not specified bythe manufactu
19、rer, all plate warmers and accessories featuringadjustable input rates shall be conducted with all accessoriesand brewers at 100 % input ratings.4.2 The coffee brewer is connected to the appropriateelectrical and water metering devices. If applicable, the internalwater tank is evacuated prior to tes
20、ting. The measured maxi-mum energy input is determined and checked against the ratedinput before continuing with testing. Total volume of waterused to fill the tank will also be recorded.4.3 The internal water tank temperature and energy con-sumption is monitored in the, preheating mode, ready-to-br
21、ew(idle) mode, energy save mode, and accessories (plate warm-ers) on and off.4.4 Energy consumption and time are monitored while thecoffee brewer is used to brew coffee sequentially to replicate aheavy use period.5. Significance and Use5.1 The measured maximum energy input rate is used toconfirm tha
22、t the coffee brewer is operating in accordance withits nameplate rating.5.2 If applicable and accessible, the boiler or internal tanktemperature is measured to ensure that the water is maintainedat a ready-to-brew temperature. This can also be used later tonormalize coffee brewer energy consumption
23、to a standardtemperature.5.3 The Preheat Test can be used to gauge the amount oftime and energy required for the coffee brewer to reach aready-to-brew state from the ambient room and incoming watertemperatures.5.4 Ready-to-Brew and Energy Save Mode energy can beused by end users to estimate the amou
24、nt of energy consumedwhile coffee is not being brewed.5.5 Heavy-use energy consumption can be used to estimatehow much energy is consumed by the coffee brewer whenbrewing coffee. Along with preheat and ready-to-brew(standby) energy, this value can be used by end users to modeltheir machine energy us
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMF29902012STANDARDTESTMETHODFORCOMMERCIALCOFFEEBREWERS 商业 咖啡 啤酒 标准 试验 方法 PDF

链接地址:http://www.mydoc123.com/p-539867.html