ASTM F2819-2010 Standard Test Methods for Measurement of Straightness of Bar Rod Tubing and Wire to be used for Medical Devices《测量医疗设备用棒材 条材 管材和线材的标准试验方法》.pdf
《ASTM F2819-2010 Standard Test Methods for Measurement of Straightness of Bar Rod Tubing and Wire to be used for Medical Devices《测量医疗设备用棒材 条材 管材和线材的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM F2819-2010 Standard Test Methods for Measurement of Straightness of Bar Rod Tubing and Wire to be used for Medical Devices《测量医疗设备用棒材 条材 管材和线材的标准试验方法》.pdf(6页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: F2819 10Standard Test Methods forMeasurement of Straightness of Bar, Rod, Tubing and Wireto be used for Medical Devices1This standard is issued under the fixed designation F2819; the number immediately following the designation indicates the year oforiginal adoption or, in the case of r
2、evision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This standard covers the various test methods to be usedfor measurement of straightness of bar, r
3、od, tubing, and wire.These test methods apply primarily to bar, rod, tubing, and wirethat are ordered in the straightened and cut-to-length condition.It also applies to small diameter tubing and wire that has beenspecially processed to roll off a spool in the straightenedcondition.1.2 These test met
4、hods apply to straightness of round wirethat has a diameter between 0.05 and 4.78 mm (0.002 and0.188 in.). They also apply to flatness (camber) of flat-shapedwire or ribbon with a maximum dimension between 0.05 and4.78 mm (0.002 and 0.188 in.). For flatness (camber) measure-ment, refer to Test Metho
5、d F2754/F2754M.NOTE 1The current version of Test Method F2754/F2754M covers adifferent diameter range (0.0127 to 4.78 mm (0.0005 to 0.188 in.) anddoes not include superelastic NiTi. These exceptions would not affect thecamber measurement as conducted by Test Method F2754/F2754M.1.3 These test method
6、s apply to straightness of round tubingthat has an outer diameter between 0.05 and 6.35 mm (0.002and 0.25 in.).1.4 These test methods apply to straightness of round rodthat has a diameter between 4.78 and 6.35 mm (0.188 and 0.25in). It also applies to flatness (camber) of flat and shaped rodwith a m
7、aximum dimension between 4.78 and 6.35 mm (0.188and 0.25 in). For measurement of flatness (camber), refer toTest Method F2754/F2754M.NOTE 2The current version of Test Method F2754/F2754M covers adifferent diameter range (0.0127 to 4.78 mm (0.0005 to 0.188 in.) anddoes not include superelastic NiTi.
8、These exceptions would not affect thecamber measurement as conducted by Test Method F2754/F2754M.1.5 These test methods apply to straightness of round barthat has a diameter between 6.35 and 101.6 mm (0.25 and 4 in).It also applies to flatness (camber) of flat and shaped bar witha maximum dimension
9、between 6.35 and 101.6 mm (0.25 and4 in). For measurement of flatness (camber), refer to TestMethod F2754/F2754M.NOTE 3The current version of Test Method F2754/F2754M covers adifferent diameter range (0.0127 to 4.78 mm (0.0005 to 0.188 in.) anddoes not include superelastic NiTi. These exceptions wou
10、ld not affect thecamber measurement as conducted by Test Method F2754/F2754M.1.6 These test methods apply to ferrous and non-ferrousalloys including linear-elastic or superelastic nitinol. Refer toTerminology F2005 for more details on NiTi terminology.1.7 The values stated in either SI units or inch
11、-pound unitsare to be regarded separately as standard. The values stated ineach system may not be exact equivalents; therefore, eachsystem shall be used independently of the other. Combiningvalues from the two systems may result in non-conformancewith the standard.1.8 This standard does not purport
12、to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2F2005 T
13、erminology for Nickel-Titanium Shape MemoryAlloysF2754/F2754M Test Method for Measurement of Camber,Cast, Helix and Direction of Helix of Coiled Wire2.2 Other Standards:3GGG-P-463 U.S. Federal Specification: Plate, Surface(Granite)3. Terminology3.1 Fig. 1 and Fig. 2 show the physical meaning ofstrai
14、ghtness. Fig. 3 shows the definition of wobble in a straightwire as it is being rotated.1These test methods are under the jurisdiction of ASTM Committee F04 onMedical and Surgical Materials and Devices and is the direct responsibility ofSubcommittee F04.15 on Material Test Methods.Current edition ap
15、proved Dec. 15, 2010. Published January 2011 DOI: 10.1520/F281910.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM web
16、site.3Available from IHS, 321 Inverness Drive South Englewood, CO 80112,http:/.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.3.2 Definitions of Terms Specific to This Standard:3.2.1 straightnessDeviation of an axis or surface eleme
17、ntfrom linearity over a unit length in the unloaded (force andmoment free) condition.Aperfectly straight condition is shownin Fig. 1. An unloaded condition is shown in Fig. 2.3.2.2 wobbleElliptical rotation observed in a small diam-eter wire or tube as it is being rotated around a central axis asis
18、shown in Fig. 3.4. Summary of Test Method4.1 For bar, rod, tube, and wire, the deviation from thecondition of resting flat on a smooth surface can be measuredby using a quantitative or qualitative test method. Two quan-titative and two qualitative methods are the gap and TIR (TotalIndicator Readout)
19、 and inclined flat plate and finger roll tests,respectively4.2 Inclined Flat Plate Test (qualitative test method that canbe made quantitative)A common method for measurementof straightness of wire or tubing with a diameter less than 4.78mm (0.188 in.) is the inclined flat plate test. In this method,
20、 asectioned piece of material is allowed to roll down an inclinedtable as is illustrated by Fig. 4 and Fig. 5. The material passesthe test if it rolls freely down the table l without stopping as isshown by Fig. 5.4.3 Finger-Roll Test (qualitative test method)A secondcommon method for measurement of
21、straightness that is usedfor wire and tubing with a diameter less than 0.25 mm (0.010in.) is the finger-roll test. In this test, a cut length of wire ortubing is laid on a flat surface. A finger, pencil, pen, or plasticcard is used to rotate the center of the sample back and forth onthe flat surface
22、. The opposite ends of the sample should rotatesmoothly without wobble as is defined in 3.2.2 of these testmethods.4.4 Gap Test (quantitative test method)A common quan-titative method for measurement of straightness of wire with adiameter less than 4.78 mm (0.188 in.) is the gap test. It canFIG. 1 D
23、efinition of a “Straight” ConditionFIG. 2 Definition of a “Nonstraight” ConditionFIG. 3 Definition of Wobble in a Small Diameter Tube or Wire as it is Being RotatedF2819 102also be used for rod with a diameter between 4.78 and 6.35 mm(0.188 and 0.25 in.), tubing with diameter 0.05 to 6.35 mm(0.0002
24、to 0.25 in.) or bar with a diameter between 6.35 to101.7 mm (0.25 to 4 in.), the gap test can be used to measurestraightness. The gap test can also be used for flat or shapedwire and ribbon. In this method, a thickness gauge equal to thegap must not fit between the rod, tubing, or bar and flat surfa
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMF28192010STANDARDTESTMETHODSFORMEASUREMENTOFSTRAIGHTNESSOFBARRODTUBINGANDWIRETOBEUSEDFORMEDICALDEVICES

链接地址:http://www.mydoc123.com/p-539534.html