ASTM F2795-2011 Standard Test Method for Performance of Self-Contained Soft Serve and Shake Machines《自足软雪糕和奶昔机性能的标准试验方法》.pdf
《ASTM F2795-2011 Standard Test Method for Performance of Self-Contained Soft Serve and Shake Machines《自足软雪糕和奶昔机性能的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM F2795-2011 Standard Test Method for Performance of Self-Contained Soft Serve and Shake Machines《自足软雪糕和奶昔机性能的标准试验方法》.pdf(10页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: F2795 11Standard Test Method forPerformance of Self-Contained Soft Serve and ShakeMachines1This standard is issued under the fixed designation F2795; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last rev
2、ision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method evaluates the energy consumption andperformance of soft serve ice cream and shake machines. Thefood service o
3、perator can use this test to evaluate and select anappropriate soft serve or shake machine and understand itsenergy consumption and production capabilities.1.2 This test method applies to the following types of softserve and shake machines: (any of which may or may not havea reservoir for liquid mix
4、). Included in these test methods areconventional and heat-treatment freezers. The unit may includeseparate refrigeration systems for the frozen product and freshmix and may be either air-cooled or water-cooled.1.3 The soft serve/shake machines will be tested for thefollowing (where applicable):1.3.
5、1 Maximum power input, or maximum current draw,1.3.2 Initial freeze-down energy consumption and duration,1.3.3 Heavy-use energy consumption,1.3.4 Production capacity,1.3.5 Overrun,1.3.6 Impact performance,1.3.7 Idle energy rate, and1.3.8 Heat treat cycle energy consumption (if applicable).1.4 This s
6、tandard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.
7、1 ASTM Standards:2F1604 Specification for Freezers, Ice Cream, Soft Serve,Shake2.2 Code of Federal Regulations:321 CFR 135.110 Ice cream and frozen custard2.3 NSF/ANSI Standard:4NSF/ANSI 6 Dispensing freezers3. Terminology3.1 Definitions:3.1.1 air cooled unit, na unit which uses air passing overa ma
8、in condenser in the freezer cylinder refrigeration system.3.1.2 combination unit, na unit employing two maincompressors and two main condensers with one or twocondenser fan motors and two separate freezer doors (that is,one for soft serve and another for shake), designed to dispenseshake and soft se
9、rve product in the same footprint.3.1.3 freeze-down energy, namount of energy consumed(kWh) by the soft serve machine while cooling the product toa servable temperature.3.1.4 freeze-down time, ntime required for the soft servemachine while cooling the product to a servable temperature.3.1.5 heat tre
10、atcool phase, nportion of the heat treatcycle which involves cooling the product from 150F(65C) to 41F (5C) within a period of 120 min or less.3.1.6 heat treatheat phase, nportion of the heat treatcycle which involves elevating product temperature from41F (5C) to 150F (66C) within a period of 90 min
11、.3.1.7 heat treathold phase, nportion of the heat treatcycle which involves holding the product above a 150F(66C) for a period of at least 30 min.3.1.8 heat-treatment freezers, nas defined in SpecificationF1604, operate as conventional freezers and heat all product to150F (66C) minimum for at least
12、30 min daily to destroyundesirable microorganisms.3.1.9 ice cream or ice-cream (originally, iced cream), nafrozen dessert made from dairy products, such as milk andcream, combined with flavorings and sweeteners, such as1This test method is under the jurisdiction of ASTM Committee F26 on FoodService
13、Equipment and is the direct responsibility of Subcommittee F26.06 onProductivity and Energy Protocol.Current edition approved Dec. 1, 2011. Published November 2012. DOI:10.1520/F2795-11.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceas
14、tm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Available from U.S. Government Printing Office Superintendent of Documents,732 N. Capitol St., NW, Mail Stop: SDE, Washington, DC 20401, http:/www.access.gpo.gov.4Available f
15、rom American National Standards Institute (ANSI), 25 W. 43rd St.,4th Floor, New York, NY 10036, http:/www.ansi.org.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.sugar, and possible other ingredients. (21 CFR 135.110)3.1.10 idle ene
16、rgy rate, nthe rate of energy consumed(kWh) by the soft serve or shake machine while holding ormaintaining the product in a ready-to-serve state withoutdispensing product.3.1.11 interval, nlength of time for one operator to drawa portion of product from a soft serve machine.3.1.12 mix, na fluid that
17、 contains 4 to 6 % butterfat and isa vanilla flavor.3.1.13 overrun, nthe increase in volume due to incorpo-ration of air while freezing soft serve and shake products underagitation, calculated by this formula:Overrun 5Weight of liquid mix Weight of frozen product!Weight of frozen product(1)3.1.14 pr
18、oduct, nmix that is frozen under agitation tospecific temperature without syrup that is ready to serve.3.1.15 shake, na sweet, cold beverage which is madefrom milk, ice cream, and flavorings or sweeteners such as fruitsyrup or chocolate sauce.3.1.16 spout adaptor, na device which is attached to thef
19、reezer door spout to assist in the filling of sampling container.3.1.17 standby idle energy, nthe rate of energy consumed(kWh) by the soft serve machine while holding or maintainingthe product 41F (5C) without dispensing product. Alsoreferred to as night mode in NSF/ANSI 6.3.1.18 test method, na def
20、initive procedure for the iden-tification, measurement, and evaluation of one or more quali-ties, characteristics, or properties of a material, product,system, or service that produces test results.3.1.19 twin single spout freezer, na machine employingeither of the above configurations (Twin Twist m
21、achine “A” or“B”) but with two single spout doors which can only dispensefrom one Freezer Cylinder.3.1.20 twin twist freezer “A”, na machine using two maincompressors and two main condensers with one or twocondenser fan motors and a freezer door (3 spout) which thecenter spout draws from both freeze
22、r cylinders.3.1.21 twin twist freezer “B”, na machine with singlemain compressor, single main condenser fan motor, with afreezer door (3 spout) which the center spout draws productfrom both freezer cylinders.3.1.22 uncertainty, na measure of systematic and preci-sion errors in specified instrumentat
23、ion or measure of repeat-ability of a recorded test result.3.1.23 water cooled unit, na unit which uses waterpassing through a twin tube condenser in the freezer cylinderrefrigeration system.4. Summary of Test Method4.1 This test method is designed to address machines whichhave self contained refrig
24、eration system(s) for the main freez-ing cylinder(s) and may or may not contain a mix storagesystem as part of the unit.4.2 Power input is determined to confirm that the soft servemachine is operating below maximum nameplate power rating.4.3 The hopper and barrel are loaded with 35 6 1F (1.5 60.5C)
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMF27952011STANDARDTESTMETHODFORPERFORMANCEOFSELFCONTAINEDSOFTSERVEANDSHAKEMACHINES 自足 雪糕 奶昔 性能 标准

链接地址:http://www.mydoc123.com/p-539487.html