ASTM F2199-2002 Standard Test Method for Determining Dimensional Stability of Resilient Floor Tile after Exposure to Heat《测定受热后弹性地板砖尺寸稳定性的标准试验方法》.pdf
《ASTM F2199-2002 Standard Test Method for Determining Dimensional Stability of Resilient Floor Tile after Exposure to Heat《测定受热后弹性地板砖尺寸稳定性的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM F2199-2002 Standard Test Method for Determining Dimensional Stability of Resilient Floor Tile after Exposure to Heat《测定受热后弹性地板砖尺寸稳定性的标准试验方法》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: F 2199 02Standard Test Method forDetermining Dimensional Stability of Resilient Floor Tileafter Exposure to Heat1This standard is issued under the fixed designation F 2199; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revisio
2、n, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the determination of the changein linear dimensions of resilient floor tile af
3、ter exposure to heat.1.2 The values stated in inch-pound units shall be regardedas the standard.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health p
4、ractices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:E 177 Practice for Use of the Terms Precision and Bias inASTM Test Methods2E 691 Practice for Conducting an Interlaboratory Study toDetermine the Precision of a Test Method2F 14
5、1 Terminology Relating to Resilient Floor Coverings3F 536 Test Method for Size of Resilient Floor Tile by DialGage Method3F 2055 Test Method for Size and Squareness of ResilientFloor Tile by Dial Gage Method33. Terminology3.1 Definitions are in accordance with Terminology F 141unless otherwise indic
6、ated.4. Significance and Use4.1 The final appearance of an installed tile floor dependsupon several factors. These include but are not limited to sizeand squareness of the tile, the quality of joint cut, the qualityand preparation of the subfloor and the skill of the installer.Long term appearance o
7、f the installed floor is also dependenton but not limited to the ability of the tile to resist shrinkagedue to internal stress relief. This test method is used to measurethe ability of floor tile to retain its original dimensionsfollowing exposure to heat simulating a long service life atreasonable
8、and expected temperatures.5. Apparatus5.1 Mechanical Convection-Type Oven, or equivalent, ca-pable of maintaining a temperature of 180 6 3.6F (82 6 2C),with inside dimensions large enough to hold several tileshorizontally on aluminum exposure plates.5.2 Specimen Exposure Plates, consisting of flat 1
9、4gage,0.0625in. (1.6mm), thick aluminum. The aluminum expo-sure plates may be contained in a rack, either fixed in orremovable from the rack, and should be at least 1 in. (25.4 mm)larger in each linear dimension than the linear dimension of thespecimen tested. If contained in a rack, the spacing bet
10、weeneach plate should be at least 0.625in. (16mm). The rack shallbe constructed with all four sides open.5.3 Block and Dial Gage Assembly, as described in TestMethod F 536 or F 2055.5.4 Forced Air Cooling (Fan, Blower, etc.), may be used foraccelerating specimen conditioning before heating and after
11、cooling exposure to ensure proper equilibrium of test specimen(see 6.1 and 7.1).6. Test Specimen6.1 The test specimen consists of a resilient floor tile.Typical floor tile dimensions are 9 by 9 in. (229 by 229 mm) or12 by 12 in. (305 by 305 mm). Other sizes in square orrectangular dimensions may als
12、o be tested.7. Conditioning7.1 A conditioned room maintained at a temperature of 73.46 1.8F (23 6 1C) and 50 6 5 % relative humidity.8. Procedure8.1 Reference PlatesDifferent tile sizes, with respectivereference plates, can be specified if the size and squarenessapparatus is designed to handle the t
13、esting and measurement ofalternate sizes.8.2 Conditioning Before ExposureCondition the speci-mens at 73.4 6 1.8F (23 6 1C) and 50 6 5 % relativehumidity for not less than 24 h prior to starting the test unlessotherwise specified.1This test method is under the jurisdiction of ASTM Committee F06 on Re
14、silientFloor Coverings and is the direct responsibility of Subcommittee F06.30 on TestMethodsPerformance.Current edition approved Aug. 10, 2002. Published October 2002.2Annual Book of ASTM Standards, Vol 14.02.3Annual Book of ASTM Standards, Vol 15.04.1Copyright ASTM International, 100 Barr Harbor D
15、rive, PO Box C700, West Conshohocken, PA 19428-2959, United States.8.3 Conditions for MeasurementMeasure the tile speci-men (6.1) in the conditioning room (7.1).8.4 Calibration of Block and Dial Gage IndicatorsCalibrate the block and dial gage indicators as indicated in TestMethod F 536 or F 2055.8.
16、5 Initial MeasurementPlace the tile specimen, afterconditioning (8.2), on the block and dial gage assembly (5.3)face up and measure in the machine direction (MD), ifidentifiable, and the across machine direction (AMD), ifidentifiable, according to the procedure in Test Method F 536or F 2055. These p
17、oints shall be marked as a reference on thetile so that the final measurements will be made at the sameexact locations. Measure the tile according to Test MethodF 536 or F 2055 and eliminating the squareness measurementstep.8.6 ExposurePlace the tile specimen face up in theexposure rack (5.2) on the
18、 aluminum exposure plates. Positionthe plates on racks in the heated cabinet (5.1) at 180 6 3.6F(82 6 2C) for 6 6 0.25 h. Expose the four open sides of therack to the direction of the airflow within the cabinet so that thecirculating air passes freely over the tile specimens.8.7 Conditioning after E
19、xposureRemove the tile/plateassembly from the oven cabinet (5.1). Allow the assembly tocondition at room temperature (7.1) for at least 24 h. Weargloves when handling the hot aluminum plate.8.8 Final MeasurementsDetermine the dimensional sta-bility by measuring the separation of reference points bef
20、oreand after the heat exposure for both MD and AMD. Removethe tile from the aluminum plate after re-conditioning andre-measure on the block and dial gage assembly (5.3) accord-ing to 8.5. Make the measurements at the same reference pointsas the initial measurements.NOTE 1Squareness measurements are
21、not to be taken or recordedsince they are not directly considered in the dimensional stabilitydetermination.9. Calculations9.1 The final MD average measurements are subtractedfrom initial MD average measurements. The dimensionalstability is recorded and reported in inches (0.001 in.) Anegative value
22、 indicates shrinkage, and a positive value indi-cates expansion.9.2 The final AMD average measurements are subtractedfrom initial AMD average measurements. The dimensionalstability is recorded and reported in inches (0.001 in.) Anegative value indicates shrinkage, and a positive value indi-cates exp
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMF21992002STANDARDTESTMETHODFORDETERMININGDIMENSIONALSTABILITYOFRESILIENTFLOORTILEAFTEREXPOSURETOHEAT

链接地址:http://www.mydoc123.com/p-538020.html