ASTM F1871-2011 Standard Specification for Folded Formed Poly (Vinyl Chloride) Pipe Type A for Existing Sewer and Conduit Rehabilitation《现有下水道和管道修复用折叠式 成形聚氯乙烯 A 型管技术标准规范》.pdf
《ASTM F1871-2011 Standard Specification for Folded Formed Poly (Vinyl Chloride) Pipe Type A for Existing Sewer and Conduit Rehabilitation《现有下水道和管道修复用折叠式 成形聚氯乙烯 A 型管技术标准规范》.pdf》由会员分享,可在线阅读,更多相关《ASTM F1871-2011 Standard Specification for Folded Formed Poly (Vinyl Chloride) Pipe Type A for Existing Sewer and Conduit Rehabilitation《现有下水道和管道修复用折叠式 成形聚氯乙烯 A 型管技术标准规范》.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: F1871 11An American National StandardStandard Specification forFolded/Formed Poly (Vinyl Chloride) Pipe Type A forExisting Sewer and Conduit Rehabilitation1This standard is issued under the fixed designation F1871; the number immediately following the designation indicates the year ofor
2、iginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This specification covers requirements and test methodsfor ma
3、terials, dimensions, workmanship, flattening resistance,impact resistance, pipe stiffness, extrusion quality, and a formof marking for folded/formed poly (vinyl chloride) (PVC) pipefor existing sewer and conduit rehabilitation.1.2 Pipe produced to this specification is for use in non-pressure sewer
4、and conduit rehabilitation where the foldedPVC pipe is installed into and then expanded to provide a closefit to the wall of the original conduit, forming a new structuralpipe-within-a-pipe.NOTE 1For installation procedures refer to Practice F1867.1.3 This specification includes pipe made only from
5、mate-rials specified in Section 6. This specification does not includepipe manufactured from reprocessed, recycled, or reclaimedPVC.1.4 The values stated in inch-pound units are to be regardedas the standard. The SI units given in parentheses are providedfor information only.1.5 The following precau
6、tionary statement pertains only tothe test method portion, Section 11, of this specification. Thisstandard does not purport to address all of the safety concerns,if any, associated with its use. It is the responsibility of the userof this standard to establish appropriate safety and healthpractices
7、and determine the applicability of regulatory limita-tions prior to use.1.6 There is no similar or equivalent ISO Standard.2. Referenced Documents2.1 ASTM Standards:2D618 Practice for Conditioning Plastics for TestingD638 Test Method for Tensile Properties of PlasticsD648 Test Method for Deflection
8、Temperature of PlasticsUnder Flexural Load in the Edgewise PositionD790 Test Methods for Flexural Properties of Unreinforcedand Reinforced Plastics and Electrical Insulating MaterialsD1600 Terminology for Abbreviated Terms Relating toPlasticsD1784 Specification for Rigid Poly(Vinyl Chloride) (PVC)Co
9、mpounds and Chlorinated Poly(Vinyl Chloride)(CPVC) CompoundsD2122 Test Method for Determining Dimensions of Ther-moplastic Pipe and FittingsD2152 Test Method for Adequacy of Fusion of ExtrudedPoly(Vinyl Chloride) (PVC) Pipe and Molded Fittings byAcetone ImmersionD2412 Test Method for Determination o
10、f External LoadingCharacteristics of Plastic Pipe by Parallel-Plate LoadingD2444 Test Method for Determination of the Impact Resis-tance of Thermoplastic Pipe and Fittings by Means of aTup (Falling Weight)F412 Terminology Relating to Plastic Piping SystemsF1057 Practice for Estimating the Quality of
11、 Extruded Poly(Vinyl Chloride) (PVC) Pipe by the Heat Reversion Tech-niqueF1867 Practice for Installation of Folded/Formed Poly (Vi-nyl Chloride) (PVC) Pipe Type A for Existing Sewer andConduit Rehabilitation2.2 Federal Standard:3Fed. Std. No. 123 Marking for Shipment (Civil Agencies)2.3 Military St
12、andard:3MIL-STD-129 Marking for Shipment and Storage3. Terminology3.1 Definitions: Definitions are in accordance with Termi-nology F412, and abbreviations are in accordance with Termi-nology D1600, unless otherwise specified. The abbreviation forpoly(vinyl chloride) plastics is PVC.3.1.1 The term TY
13、PE A is not an abbreviation, but rather anarbitrary designation for PVC compounds with a minimumvalue for modulus in tension as listed in 6.1 and a maximumvalue as defined by cell limit 1 of Specification D1784.1This standard is under the jurisdiction of Committee F17 on Plastic PipingSystems and is
14、 the direct responsibility of Subcommittee F17.67 on TrenchlessPlastic Pipeline Technology.Current edition approved April 1, 2011. Published May 2011. Originallyapproved in 1998. Last previous edition approved in 2002 as F1871-02e1which waswithdrawn January 2011 and reinstated in April 2011. DOI: 10
15、.1520/F1871-11.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Available from Standardization Documents Orde
16、r Desk, DODSSP, Bldg. 4,Section D, 700 Robbins Ave., Philadelphia, PA 19111-5098, http:/dodssp.daps.dla.mil.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.3.2 Definitions of Terms Specific to This Standard:3.2.1 folded pipe, npipe t
17、hat has been manufactured andcalibrated round, then subsequently cooled and deformed intoa folded shape for use in existing sewer and conduit rehabili-tation (see Fig. 1).3.2.2 formed pipe, nA folded pipe that has been insertedinto an existing sewer or conduit and expanded with steam heatand pressur
18、e, and, if required by the manufacturer, with asqueegee device or similar device to provide a close fit to theexisting pipe (see Fig. 1).3.2.3 formed field sample, nA formed field sample isformed when the folded pipe has been inserted into a mold pipeand expanded with steam heat and pressure, and, i
19、f required bythe manufacturer, with a squeegee device or similar device toprovide a close fit to the mold pipe.4. Significance and Use4.1 This specification is for use by designers and specifiers,regulatory agencies, owners, and inspection organizations whoare involved in the rehabilitation of non-p
20、ressure sewers andconduits. Modifications may be required, depending on specificjob conditions to establish a project specification. The manu-facturer of the product should be consulted for design andinstallation information. Industrial waste disposal lines shouldbe installed only with the specific
21、approval of the cognizantcode authority, since chemicals not commonly found in drainsand sewers and temperatures in excess of 140F (60C) may beencountered.5. Applications of Material5.1 The nominal folded PVC pipe sizes specified in Section8 can be obtained for use in a range of original pipe inside
22、diameters. Table 1 presents recommended ranges that areavailable for each nominal size.6. Materials and Manufacture6.1 Basic MaterialsThe pipe shall be made from virginPVC compound meeting all the requirements for cell classifi-cation 12111 as defined in Specification D1784 and withminimum physical
23、properties as listed below:Tensile Strength Test Method D638 3 600 PSI (25 MPa)Tensile Modulus Test Method D638 155 000 PSI (1069 MPa)Flexural Strength Test Method D790 4 100 PSI (28 MPa)Flexural Modulus Test Method D790 145 000 PSI (1000 MPa)Heat Deflection Test Method D648 115F (46C)Temperature te
24、sted at264 psi(2 MPa)6.1.1 Compounds meeting the above minimum propertiesthat have different cell classifications because one or moreproperties are greater than those of the specified compoundsare also acceptable, except modulus in tension shall not exceed280 000 psi.NOTE 1This figure is intended on
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMF18712011STANDARDSPECIFICATIONFORFOLDEDFORMEDPOLYVINYLCHLORIDEPIPETYPEAFOREXISTINGSEWERANDCONDUITREHABILITATION

链接地址:http://www.mydoc123.com/p-535910.html