ASTM F1761-2000(2005) Standard Test Method for Pass Through Flux of Circular Magnetic Sputtering Targets《圆形磁射极板磁力线通过量的标准试验方法》.pdf
《ASTM F1761-2000(2005) Standard Test Method for Pass Through Flux of Circular Magnetic Sputtering Targets《圆形磁射极板磁力线通过量的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM F1761-2000(2005) Standard Test Method for Pass Through Flux of Circular Magnetic Sputtering Targets《圆形磁射极板磁力线通过量的标准试验方法》.pdf(11页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: F 1761 00 (Reapproved 2005)Standard Test Method forPass Through Flux of Circular Magnetic Sputtering Targets1This standard is issued under the fixed designation F 1761; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, t
2、he year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers measuring the dc magnetic fieldtransmitted through a ferromagnetic sputtering targ
3、et (“passthrough flux” or “PTF”). In this test method the sourcemagnetic field is in the test targets circumferential direction.1.2 Planar disk-shaped targets in the diameter range 5 to 8in. inclusive (125 to 205 mm inclusive) and of thickness 0.1 to0.5 in. inclusive (2.5 to 13 mm) may be characteri
4、zed by thisprocedure.1.3 This test method is also applicable to targets having anopen center, for example, to targets 5-in. outside diameter by2.5-in. inside diameter by 0.25-in. thick (127-mm outsidediameter by 63.5-mm inside diameter by 6.35-mm thick).1.4 Targets of various diameters and thickness
5、es are accom-modated by suitable fixturing to align the piece under test withthe source magnet mounted in the test fixture. Tooling, cover-ing several popular target designs is specified in this procedure.Additional target configurations may be tested by providingspecial tooling. When special fixtur
6、ing is used all partiesconcerned with the testing must agree to the test setup.1.5 The values stated in inch-pound units are to be regardedas the standard. The values given in parentheses are forinformation only.1.6 This standard does not purport to address all of thesafety concerns, if any, associa
7、ted with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Terminology2.1 Definitions:2.1.1 pass through flux (PTF), (n)For purposes of thisstandard the 88pass
8、 through flux” is the dc magnetic fieldtransmitted through a ferromagnetic sputtering target, from oneface to the opposite face.2.1.1.1 DiscussionPTF is also frequently called 88leakageflux.”2.1.2 reference field, nFor purposes of this standard the“reference field” is the dc magnetic field measured
9、with theHall probe Gaussmeter when no sputtering target is in positionon the test stand. The strength of the reference field dependsupon the height and position of the Hall probe relative to thesource magnet.2.1.3 source field, nFor purposes of this standard the“source field” is the dc magnetic fiel
10、d measured with the Hallprobe at the top surface of the target support table.3. Summary of Test Method3.1 The sputtering target under test is mounted on a testfixture in which a permanent horseshoe-shaped magnet is heldin proximity to one of the flat planar faces of the target. A Hallprobe Gaussmete
11、r is used to measure the dc magnetic fieldpenetrating the target and entering the air space from targetsopposite face.4. Significance and Use4.1 It is standard practice to use magnetron cathode sputterdeposition sources in manufacturing thin film magnetic datastorage media. But a ferromagnetic sputt
12、ering target tends toshunt a sputtering cathodes magnetic field, thus reducing theefficiency of the sputtering process.4.2 Makers of sputtering targets have developed variousmeans of controlling alloy microstructure to minimize theundesirable cathode shunting effect. Because of their differingmanufa
13、cturing methods, however, the targets of one suppliermay have magnetic properties significantly better or worse thanthose of another, even when the alloy compositions are thesame.4.3 This test method permits comparing the magnetic shunt-ing power of magnetic targets under a standard test condition.T
14、he results are useful to sputtering target suppliers and buyersin predicting target performance, in specifying target quality,and in qualifying incoming target shipments. This test may alsobe useful in quantifying target improvement efforts.4.4 Manufacturing process steps that lower a target materi-
15、als magnetic permeability tend to increase the PTF, and viceversa. It would in principle be possible to predict the PTF by1This test method is under the jurisdiction of ASTM Committee F01 onElectronics and is the direct responsibility of Subcommittee F01.17 on SputteredThin Films.Current edition app
16、roved May 1, 2005. Published June 2005. Originallyapproved in 1996. Last previous edition approved in 2000 as F 1761 00.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.accumulating sufficient permeability data, and knowing thetarget
17、thickness and the field intensity of the magnetic assem-bly used for magnetron sputtering.5. Interferences5.1 The magnetic test fixture must be located in an area freeof extraneous ferromagnetic materials and strong magneticfields that would interfere with the source magnettest speci-men dc magnetic
18、-field configuration.5.2 The “magnetic conditioning” effect is strong in somesputtering target alloys. It is important to verify that the targetunder test is magnetically stabilized before finalizing a data set(see 9.2).6. Apparatus6.1 This method requires the use of a special test fixture. Itsconst
19、ruction is specified in Appendix X1.6.2 Gaussmeter, is required, equipped with a portabletransverse-field Hall probe blade nominally 0.040-in. thick by0.170-in. wide by 2.5-in. long (1.0-mm by 4.3-mm by 64 mm).The Gaussmeter must be capable of measuring dc magneticfields in the range 10 Gauss to 350
20、0 Gauss, inclusive, to anaccuracy of 62 %. This unit is designated the “measuringGaussmeter,” and is used for making the magnetic fieldmeasurements specified in this test method.6.2.1 It is important that the semiconductor Hall probesensing element be mounted at the extreme tip end of theprobe. The
21、distance from the probe tip to the center of thesensing element must not exceed 0.030 in. (0.75 mm).6.3 It is convenient to have a second Gaussmeter available,also equipped with a portable transverse-field Hall probe blade.This unit must be capable of measuring dc magnetic fields inthe range 1 Gauss
22、 to 50 Gauss, inclusive, to an accuracy of620 %. This unit is referred to in 8.1 as the “screeningGaussmeter.” It is used to monitor residual magnetic fields intest specimen sputtering targets.NOTE 1If a “screening Gaussmeter” is not available, the targets undertest must be degaussed and verified (8
23、.3) using the measuring Gaussmeter,before starting Section 7.6.4 Demagnetizer2, is needed that is capable of removingthe remnant magnetization in sputtering targets to be tested.7. Preparation of Apparatus7.1 Verify that the source magnet is securely clamped withits vertical center plane located 5.7
24、50 6 0.015 in. (146.1 6 0.4mm) from the end of the baseplate. This is illustrated in Fig. 1.7.2 Verify that the pole faces of the source magnet are inlight contact with the bottom of the target support table.Adjustment of the magnets vertical position can be made byloosening the magnet clamp screws,
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMF176120002005STANDARDTESTMETHODFORPASSTHROUGHFLUXOFCIRCULARMAGNETICSPUTTERINGTARGETS 圆形 极板 磁力线 通过

链接地址:http://www.mydoc123.com/p-535578.html