《ASTM E979-2009 402 Standard Test Method for Evaluation of Antimicrobial Agents as Preservatives for Invert Emulsion and Other Water Containing Hydraulic Fluids《评估用逆乳液与其它含水液压液作防腐剂的抗.pdf》由会员分享,可在线阅读,更多相关《ASTM E979-2009 402 Standard Test Method for Evaluation of Antimicrobial Agents as Preservatives for Invert Emulsion and Other Water Containing Hydraulic Fluids《评估用逆乳液与其它含水液压液作防腐剂的抗.pdf(6页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E 979 09Standard Practice forEvaluation of Antimicrobial Agents as Preservatives forInvert Emulsion and Other Water Containing HydraulicFluids1This standard is issued under the fixed designation E 979; the number immediately following the designation indicates the year oforiginal adopti
2、on or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.INTRODUCTIONInvert emulsion hydraulic fluids typically contain 60 % mineral oil and 40
3、 % water (by volume).These fluids routinely are prepared using proprietary, oil-soluble, emulsifying agents, as well as otheremulsifiable constituents. They are recommended for use where conditions indicate a low-cost, fireretardant product, compatible with water-based metal working fluids.The high
4、water content of these hydraulic fluids makes them susceptible to microbial attack.Uncontrolled microbial growth in these fluids can cause cartridge filter unit plugging, maladorousconditions, or general biodeterioration. Problem microorganisms associated with these fluids includebacteria and fungi.
5、The hydraulic system is essentially a closed one in which water of evaporation is added to maintaina fixed volume. The inclusion of an efficacious preservative in the water containing hydraulic fluidscan prevent microbial growth and the resulting problems that follow.1. Scope*1.1 This laboratory pra
6、ctice is designed to evaluate theutility and effectiveness of antimicrobial agents intended tocontrol microbial growth in invert emulsions and other watercontaining hydraulic fluids.NOTE 1Procedures for preparation of water soluble hydraulic fluidsand recovery of organisms appear in Practice E 2169.
7、1.2 The values stated in SI units are to be regarded asstandard. No other units of measurement are included in thisstandard.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appr
8、o-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D 1129 Terminology Relating to WaterD 4454 Test Method for Simultaneous Enumeration ofTotaland Respiring Bacteria inAquatic Systems by MicroscopyD 5
9、465 Practice for Determining Microbial Colony Countsfrom Waters Analyzed by Plating MethodsE 1326 Guide for Evaluating Nonconventional Microbio-logical Tests Used for Enumerating BacteriaE 2169 Practice for Selecting Antimicrobial Pesticides forUse in Water-Miscible Metalworking FluidsE 2523 Termino
10、logy for Metalworking Fluids and Opera-tions3. Terminology3.1 Terms used in this practice are defined in TerminologiesD 1129 and E 2523.1This practice is under the jurisdiction of ASTM Committee E35 on Pesticidesand Alternative Control Agents and is the direct responsibility of SubcommitteeE35.15 on
11、 Antimicrobial Agents.Current edition approved April 1, 2009. Published April 2009. Originallyapproved in 1984. Last previous edition approved in 2004 as E 979 91 (2004).2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annu
12、al Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1*A Summary of Changes section appears at the end of this standard.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.4. Summary
13、 of Test Method4.1 The antimicrobial agent to be evaluated is incorporatedinto an emulsion system by (a) addition to the aqueous phaseemployed in the preparation of the emulsion, (b) in doses to theformulated system, or (c) by other methods suitable for the testcompound.4.2 A heavy bacterial or fung
14、al inoculum, or both, is thenadded.4.3 The resulting mixture is aerated and passed over thesurface of a simulated filter system for a minimum period ofeight weeks either continuously or with shutdowns to simulateactual operations conditions.4.4 The degree of microbial control is determined byperiodi
15、cally quantifying the bioburden in the emulsion bydirect microscopic count (Test Method D 4454), plate count(Practice D 5465), or other appropriate method (Guide E 1326)and visual observations for microbial fouling of the simulatedfilter surface.NOTE 2A knowledge of standard microbiological techniqu
16、es is re-quired for this procedure. It is also required that good laboratory practicesbe followed throughout these tests. This means appropriate containmentfor the microbiological systems being evaluated. The systems should bemaintained in an enclosure so that during the aeration process the mistsan
17、d aerosols generated do not contaminate the laboratory environment.5. Significance and Use5.1 This procedure is designed to determine the effective-ness of antimicrobial agents intended for microbial control ininvert emulsions and other water containing hydraulic fluids.6. Apparatus6.1 Air SupplyAny
18、 air source which is free from organicvapors, organic matter, or other objectionable material may beused.NOTE 3If desired, air may be sterilized as follows:Pack two 150-mm long drying tubes (bulb type) loosely with glass woolin a series with neoprene stoppers, glass tubing, and neoprene tubing.Wrap
19、loosely in aluminum foil and steam sterilize at 15 to 20 psi for 30minutes. Cool to room temperature while still wrapped. In-line pre-sterilization air filters are available from most local laboratory supplyhouses.Insert into air line with bulbs on upstream side. Average lifetime incontinuous use is
20、 two weeks. Discard sooner if upstream filter becomeswet or contaminated with oil.6.2 Colony CounterAny one of several types may beused.6.3 IncubatorAny cabinet capable of maintaining a tem-perature of 35 6 1C may be used.6.4 Test CabinetA large cabinet capable of maintaining atemperature of 35 6 1C
21、, able to house several two litrebeakers, and into which an air line can be introduced.6.5 SterilizerAny suitable steam sterilizer capable ofproducing the conditions of sterilization is acceptable.6.6 Simulated Filters:6.6.1 Strainer, 3-in. epoxy coated,14-in. mesh gutterstrainer.36.6.2 Screen, 16 b
22、y 18 in. fiberglass screening material.NOTE 4Fiberglass mesh screening material (16 by 18 in.) is availablefrom any local hardware dealer.6.6.3 Wire, 20-gage, galvanized or stainless steel.6.7 Tubing,14-in. ID Tygon.NOTE 5Tygon is available from most local laboratory supply houses.6.8 T-Connectors,1
23、4-in. polypropylene.6.9 Laboratory BlenderAny standard adjustable speedlaboratory blender having a 2-L capacity glass or metalcontainer is satisfactory.6.10 Hypodermic Needle, 16-gage needle.6.11 Microscope, Brightfield microscope equipped with403 and 1003 objectives.6.12 Labware:6.12.1 Culture Dish
24、es100 mm by 15 mm sterile culturedishes made of glass or plastic are required for makingstandard plate counts.NOTE 6Presterilized and disposable plastic petri dishes are availablefrom most local laboratory supply houses.6.12.2 Bacteriological Pipettes of 1.1 or 2.2-mL capacity.NOTE 7Presterilized an
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME9792009402STANDARDTESTMETHODFOREVALUATIONOFANTIMICROBIALAGENTSASPRESERVATIVESFORINVERTEMULSIONANDOTHERWATERCONTAININGHYDRAULICFLUIDS

链接地址:http://www.mydoc123.com/p-533897.html