ASTM E815-2017 red 6250 Standard Test Method for Determination of Calcium Fluoride in Fluorspar by Complexometric Titrimetry《采用络合滴定法测定氟石氟化钙含量的标准试验方法》.pdf
《ASTM E815-2017 red 6250 Standard Test Method for Determination of Calcium Fluoride in Fluorspar by Complexometric Titrimetry《采用络合滴定法测定氟石氟化钙含量的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM E815-2017 red 6250 Standard Test Method for Determination of Calcium Fluoride in Fluorspar by Complexometric Titrimetry《采用络合滴定法测定氟石氟化钙含量的标准试验方法》.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E815 11E815 17Standard Test Method forDetermination of Calcium Fluoride in Fluorspar byComplexometric Titrimetry1This standard is issued under the fixed designation E815; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision,
2、 the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the determination of calcium fluoride in acid-grade fluorspar and other types of
3、fluorspar that canbe rendered soluble by the procedure described in the test method.1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.1.3 This test method has been evaluated in accordance with Practice E1601 and Guide E1763.
4、 Unless otherwise noted in theprecision and bias section, the lower limit in the scope of each method specifies the lowest analyte content that may be analyzedwith acceptable error (defined as a nominal 5 % risk of obtaining a 50 % or larger relative difference in results on the same testsample in t
5、wo laboratories).1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibilityof the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatorylimitations prior to use.
6、1.5 This international standard was developed in accordance with internationally recognized principles on standardizationestablished in the Decision on Principles for the Development of International Standards, Guides and Recommendations issuedby the World Trade Organization Technical Barriers to Tr
7、ade (TBT) Committee.2. Referenced Documents2.1 ASTM Standards:2D1193 Specification for Reagent WaterE29 Practice for Using Significant Digits in Test Data to Determine Conformance with SpecificationsE50 Practices forApparatus, Reagents, and Safety Considerations for ChemicalAnalysis of Metals, Ores,
8、 and Related MaterialsE135 Terminology Relating to Analytical Chemistry for Metals, Ores, and Related MaterialsE276 Test Method for Particle Size or ScreenAnalysis at No. 4 (4.75-mm) Sieve and Finer for Metal-Bearing Ores and RelatedMaterialsE882 Guide for Accountability and Quality Control in the C
9、hemical Analysis LaboratoryE1601 Practice for Conducting an Interlaboratory Study to Evaluate the Performance of an Analytical MethodE1763 Guide for Interpretation and Use of Results from Interlaboratory Testing of Chemical Analysis Methods (Withdrawn2015)33. Terminology3.1 DefinitionsFor definition
10、s of terms used in this test method, refer to Terminology E135.4. Summary of Test Method4.1 The sample is decomposed by digesting with nitricHNO3 and perchloricHCLO4 acids and the fluorine is expelled by fuming.The residue is dissolved in dilute hydrochloric acid, HCL, the solution made alkaline, an
11、d the calcium titrated with standard EDTAsolution. Calcium present as carbonate is determined in a separate sample with EDTA solution, after extracting the former with1 This test method is under the jurisdiction of ASTM Committee E01 on Analytical Chemistry for Metals, Ores, and Related Materials an
12、d is the direct responsibility ofSubcommittee E01.02 on Ores, Concentrates, and Related Metallurgical Materials.Current edition approved Sept. 1, 2011May 1, 2017. Published September 2011July 2017. Originally approved in 1981. Last previous edition approved in 20042011 asE815 04.11. DOI: 10.1520/E08
13、15-11.10.1520/E0815-17.2 For referencedASTM standards, visit theASTM website, www.astm.org, or contactASTM Customer Service at serviceastm.org. For Annual Book of ASTM Standardsvolume information, refer to the standards Document Summary page on the ASTM website.3 The last approved version of this hi
14、storical standard is referenced on www.astm.org.This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Becauseit may not be technically possible to adequately depict all changes accurate
15、ly, ASTM recommends that users consult prior editions as appropriate. In all cases only the current versionof the standard as published by ASTM is to be considered the official document.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States1
16、dilute acetic acid. A correction for calcium fluoride, solubilized by dilute acetic acid digestion, is applied,applied by determiningthe fluoride in the acetic acid extract by fluoride ion-selective electrode. The CaF2 content is then calculated.5. Significance and Use5.1 Fluorspar is used as a flux
17、 in steelmaking, the steelmaking and glass industry, and in the manufacture of hydrofluoricacid.HF.5.2 This test method is intended to be used for compliance with compositional specifications for calcium fluoride content. It isassumed that all who use these procedures will be trained analysts capabl
18、e of performing common laboratory procedures skillfullyand safely. It is expected that work will be performed in a properly equipped laboratory and that proper waste disposal procedureswill be followed. Appropriate quality control practices must be followed such as those described in Guide E882.6. I
19、nterferences6.1 None of the elements normally found in fluorspar interfere with this test method.7. Apparatus7.1 Fluoride Ion-Selective Electrode. 47.2 Magnetic Stirrer and TFE-Fluorocarbon-Coated Spin Bar.7.3 pH Meter with High ImpedanceSuitable for ion-selective electrode.7.4 Polyethylene Beakers,
20、 100-mL.7.5 Single Junction Ag/AgCl Reference Electrode. 58. Reagents and Materials8.1 Purity of ReagentsReagent grade chemicals shall be used in all tests. Unless otherwise indicated, it is intended that allreagents conform to the specifications of the Committee on Analytical Reagents of the Americ
21、an Chemical Society where suchspecifications are available.6 Other grades may be used, provided it is first ascertained that the reagent is of sufficient high purityto permit its use without lessening the accuracy of the determination.8.2 Purity of WaterUnless otherwise indicated, references to wate
22、r shall be understood to mean reagent water conforming toType I or II of Specification D1193. Type III or IV may be used if they effect no measurable change in the blank or sample.8.3 Acetic Acid Solution (1 + 10) Mix 1 volume of glacial acetic acid (CH3COOH) with 10 volumes of water.8.4 Calcium Car
23、bonate, high purity (minimum 99.95 % CaCO3).8.5 Ethylenediaminetetraacetic Acid Disodium Salt (EDTA)-Na2C1100H1 144O8N22H2O Solution (0.025 mol/L)Dissolve9.3062 g of EDTA in water, transfer to a 1-L volumetric flask, dilute to volume, and mix.8.6 Hydroxynaphthol Blue Indicator Grind 0.2 g of the sal
24、t with 50 g sodium chloride (NaCl).8.7 Potassium Acetate BufferDilute 283 mL of glacial acetic acid (CH3COOH) to 1200 mL with water. While cooling andstirring, add potassium hydroxide KOH solution B (KOH) (8.9) to adjust the pH to 5.0 (approximately 350 mL of KOH solutionB are required).8.8 Potassiu
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME8152017RED6250STANDARDTESTMETHODFORDETERMINATIONOFCALCIUMFLUORIDEINFLUORSPARBYCOMPLEXOMETRICTITRIMETRY

链接地址:http://www.mydoc123.com/p-533596.html