1、Designation: E 570 97 (Reapproved 2004)e1Standard Practice forFlux Leakage Examination of Ferromagnetic Steel TubularProducts1This standard is issued under the fixed designation E 570; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision
2、, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department of Defense.e1NOTEEditorial changes were made
3、throughout the standard in January 2004.1. Scope1.1 This practice covers the application and standardizationof equipment using the flux leakage test method for detectionof outer surface, inner surface, and subsurface discontinuitiesin ferromagnetic steel tubular products (Note 1) of uniformcross sec
4、tion such as seamless and welded tubing.NOTE 1The term “tube” or “tubular product” will be used to refer toboth pipe and tubing.1.2 This practice is intended for use on tubular productshaving outside diameters from approximately12 to 24 in. (12.7to 610 mm) with wall thicknesses to12 in (12.7 mm). Th
5、esetechniques have been used for other sizes, however, and maybe so specified upon contractual agreement between thepurchaser and the supplier.1.3 This practice does not establish acceptance criteria; theymust be specified by the using parties.1.4 This standard does not purport to address the safety
6、concerns, if any, associated with its use. It is the responsibilityof the user of this standard to establish appropriate safety andhealth practices and determine the applicability of regulatorylimitations prior to use.2. Referenced Documents2.1 ASTM Standards:2E 543 Practice for Evaluating Agencies
7、that Perform Non-destructive TestingE 1316 Terminology for Nondestructive Examinations2.2 Other Documents:SNT-TC-1A Recommended for Personnel Qualification andCertification of Nondestructive Testing Personnel3ANSI/ASNT CP-189 ASNT Standard for Qualification andCertification of Nondestructive Testing
8、 Personnel3NAS-410 NAS Certification and Qualification of Nonde-structive Personnel (Quality Assurance Committee)43. Terminology3.1 Definitions of terms relating to flux leakage examinationare provided in Terminology E 1316.4. Summary of Practice4.1 This method consists of the following steps:4.1.1
9、The tube wall is magnetized at the area under exami-nation to a proper level approaching magnetic saturation.NOTE 2Tubes subjected to magnetic inspections can retain variousstrengths and configuration of residual magnetic fields depending upon themagnetization technique. If the residual field result
10、ing from a giventechnique can interfere with subsequent applications of the tube, then asupplemental demagnetization process may be required.4.1.2 A flux sensor containing magnetic transducers isplaced on or above the outside surface of the tube in themagnetized area.4.1.3 Either the tube or the flu
11、x sensor is moved at aconstant speed in the direction of the magnetic field so that thesensor scans the entire surface of the tube.1This practice is under the jurisdiction of ASTM Committee E07 on Nonde-structive Testing and is the direct responsibility of Subcommittee E07.07 onElectromagnetic Metho
12、d.Current edition approved January 1, 2004. Published February 2004. Originallyapproved in 1976. Last previous edition approved in 1997 as E 570 - 97.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStand
13、ards volume information, refer to the standards Document Summary page onthe ASTM website.3Available from The American Society for Nondestructive Testing (ASNT), P.O.Box 28518, 1711 Arlingate Ln., Columbus, OH 43228-0518.4Available from Aerospace Industries Association of America, Inc., 1250 EyeSt.,
14、NW, Washington, DC 20005.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.4.1.4 Each magnetic transducer in the flux sensor is con-nected to an electronic console which amplifies, filters, andelectronically processes the signals such
15、that significant dis-continuities are indicated (visually, audibly), and marked withpaint, or automatically removed from the production line, orboth.4.1.5 A suitable means for assuring near magnetic saturationof the product (subject to periodic check or calibration) must beprovided as part of the ex
16、amination to verify the capability ofdetection of outside diameter and inside diameter discontinui-ties.5. Significance and Use5.1 This practice outlines a procedure for examining ferro-magnetic tubular products using the flux leakage method. Ifproperly applied, this method is capable of detecting t
17、hepresence and location of significant longitudinally or trans-versely oriented discontinuities such as pits, scabs, slivers,gouges, roll-ins, laps, seams, cracks, holes, and improper weldsin ferromagnetic tubes under inspection. In addition, theseverity of a discontinuity may be estimated and a rej
18、ectionlevel set with respect to the magnitude of the electromagneticindication produced by the discontinuity.5.2 The response from natural discontinuities can be signifi-cantly different from the response for artificial discontinuitiessuch as drilled holes or notches of equivalent depth. For thisrea
19、son, sufficient work should be done to determine theconditions necessary to detect and mark natural discontinuitieswhose characteristics will adversely affect the serviceability ofthe tube, in order to establish acceptance criteria between thesupplier and purchaser.6. Basis of Application6.1 The fol
20、lowing criteria may be specified in the purchasespecification, contractual agreement, or elsewhere, and mayrequire agreement between the purchaser and supplier:6.1.1 Acceptance criteria.6.1.2 Type, dimensions, location, and number of artificialdiscontinuities to be placed on the reference standard.6
21、.1.3 Size and type of tubing to be examined.6.1.4 Extent of examination (that is, full length, weld zoneonly if welded, etc.).6.1.5 Disposition of material with discontinuity indications.6.1.6 Methods of verifying dimensions of artificial discon-tinuities and allowable tolerances.6.1.7 Time of inspe
22、ction, that is, the point(s) in the manu-facturing process at which the material will be inspected.6.1.8 Nondestructive testing (NDT) personnel shall bequalified in accordance with a nationally recognized NDTpersonnel qualification practice or standard such as ANSI/ASNT CP-189, SNT-TC-1A, MIL-STD-41
23、0, NAS-410, or asimilar document. The practice or standard used and itsapplicable revision shall be specified in the purchase specifi-cation or contractual agreement between the using parties.NOTE 3MIL-STD-410 is canceled and has been replaced with NAS-410, however, it may be used with agreement bet
24、ween contracting parties.6.1.9 If specified in the purchase specification or contractualagreement, NDT agencies shall be evaluated and qualified asdescribed in Practice E 543. The applicable edition of PracticeE 543 shall be identified in the purchase specification orcontractual agreement between th
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME57019972004E1STANDARDPRACTICEFORFLUXLEAKAGEEXAMINATIONOFFERROMAGNETICSTEELTUBULARPRODUCTS 磁钢 形制

链接地址:http://www.mydoc123.com/p-533055.html