1、Designation: F373 06F373 13Standard Test Method forEmbossed Depth of Resilient Floor Coverings1This standard is issued under the fixed designation F373; the number immediately following the designation indicates the year of originaladoption or, in the case of revision, the year of last revision.Anum
2、ber in parentheses indicates the year of last reapproval.Asuperscriptepsilon () indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department of Defense.1. Scope1.1 Two important characteristics involved in the manufacture o
3、f resilient flooring relate to the smoothness of the wear surfaceand the hardness of the layers under the wear surface. The surfaces may vary from completely textured areas to portions that areflat but separated by textured areas. This test method covers flooring with these interrupted wear surfaces
4、 which are not supportedby soft, cushioned layers.1.2 The values stated in inch-pound units are to be regarded as the standard. The values given in parentheses are for informationonly.mathematical conversions to SI units that are provided for information only and are not considered standard.1.3 This
5、 standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibilityof the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatorylimitations prior to use.2. Referenced Documents2.
6、1 ASTM Standards:2E691 Practice for Conducting an Interlaboratory Study to Determine the Precision of a Test MethodF141 Terminology Relating to Resilient Floor Coverings3. Terminology3.1 For terminology relating to Resilient Floor Coverings, see Terminology F141.4. Significance4.1 This test method i
7、s designed to measure the vertical distance between any two levels on the face of the flooring, that is,between any two flat areas, between a flat area and any part of a textured area, or between two textured areas. This vertical distancemay be of interest in itself or it may be applied to the quest
8、ions of: (1) how much of the thickness of the flooring is available beforethe pattern is destroyed; or (2) how deep the depressed areas must be before valley printing ink is not walked on in normal traffic.5. Apparatus5.1 The apparatus shall consist of a comparator stand having a flat anvil base at
9、least 6 in. (15 cm) square, equipped with a dialmicrometer graduated to 0.001 in. (0.02 mm), and a hemispherical pressure foot 132 in. (0.80 mm) in diameter. The foot shall exerta force of not more than 1 ozf (0.28 N) at any point in its travel. The force shall be obtained by an appropriate weight.
10、The plungerof the gage shall be perpendicular to the anvil.6. Test Specimen6.1 The specimen shall be a piece of flooring at least 9 by 9 in. (230 by 230 mm).1 This test method is under the jurisdiction ofASTM Committee F06 on Resilient Floor Coverings and is the direct responsibility of Subcommittee
11、 F06.20 on Test Methods- Products Construction/Materials.Current edition approved Oct. 15, 2006May 1, 2013. Published November 2006May 2013. Originally approved in 1973. Last previous edition approved in 20012006 asF37301.06. DOI: 10.1520/F0373-06.10.1520/F0373-13.2 For referencedASTM standards, vis
12、it theASTM website, www.astm.org, or contactASTM Customer Service at serviceastm.org. For Annual Book of ASTM Standardsvolume information, refer to the standards Document Summary page on the ASTM website.This document is not an ASTM standard and is intended only to provide the user of an ASTM standa
13、rd an indication of what changes have been made to the previous version. Becauseit may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current versionof the standard as published by ASTM
14、is to be considered the official document.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States17. Calibration7.1 The calibration of the gage shall be verified by means of gage blocks or shim stock traceable to national standard of knownthi
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMF3732013STANDARDTESTMETHODFOREMBOSSEDDEPTHOFRESILIENTFLOORCOVERINGS 弹性 地板 覆盖 物压纹 深度 标准 试验 方法 PDF

链接地址:http://www.mydoc123.com/p-532619.html