ASTM E3074 E3074M-2016 Standard Practice for Clearance Examinations Following Lead Hazard Reduction Activities in Single Family Dwellings in Individual Units of Multifamily Dwellin.pdf
《ASTM E3074 E3074M-2016 Standard Practice for Clearance Examinations Following Lead Hazard Reduction Activities in Single Family Dwellings in Individual Units of Multifamily Dwellin.pdf》由会员分享,可在线阅读,更多相关《ASTM E3074 E3074M-2016 Standard Practice for Clearance Examinations Following Lead Hazard Reduction Activities in Single Family Dwellings in Individual Units of Multifamily Dwellin.pdf(8页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E3074/E3074M 16Standard Practice forClearance Examinations Following Lead Hazard ReductionActivities in Single Family Dwellings, in Individual Units ofMultifamily Dwellings, and in Other Child-OccupiedFacilities1This standard is issued under the fixed designation E3074/E3074M; the numbe
2、r immediately following the designation indicates the yearof original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval.A superscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.
3、1 This practice covers visual assessment for the presenceof deteriorated paint, surface dust, painted debris, and paintchips with environmental sampling of surface dust to deter-mine whether a lead hazard exists at the time of samplecollection, following lead-hazard reduction activities, or otherbui
4、lding maintenance and modification activities.1.2 This practice addresses clearance examination of single-family detached dwellings (including exterior structures, suchas fences), individual units in multifamily dwellings, commonareas or exterior sites, and child-occupied facilities.1.3 This practic
5、e also addresses clearance examinations thatmay include soil sampling, for example when soil abatementhas been performed.1.4 This practice includes a procedure for determiningwhether regulatory requirements for lead clearance levels fordust and, where warranted, soil have been met, and, conse-quentl
6、y whether a clearance area, passes or fails a clearanceexamination.NOTE 1This practice is based on that portion of “clearance” describedfor the United States of America in 40 CFR Part 745 for abatement, andin 24 CFR Part 35 for lead-hazard reduction activities other thanabatement.1.5 The values stat
7、ed in either SI units or inch-pound unitsare to be regarded separately as standard. The values stated ineach system may not be exact equivalents; therefore, eachsystem shall be used independently of the other. Combiningvalues from the two systems may result in non-conformancewith the standard.1.6 Th
8、is standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documen
9、ts2.1 ASTM Standards:2D4840 Guide for Sample Chain-of-Custody ProceduresD5124 Practice for Testing and Use of a Random NumberGenerator in Lumber and Wood Products SimulationE631 Terminology of Building ConstructionsE1480 Terminology of Facility Management (Building-Related)E1605 Terminology Relating
10、 to Lead in BuildingsE1727 Practice for Field Collection of Soil Samples forSubsequent Lead DeterminationE1728 Practice for Collection of Settled Dust Samples UsingWipe Sampling Methods for Subsequent Lead Determi-nationE1792 Specification for Wipe Sampling Materials for Leadin Surface DustE2239 Pra
11、ctice for Record Keeping and Record Preservationfor Lead Hazard ActivitiesE2255/E2255M Practice for Conducting VisualAssessmentsfor Lead Hazards in Buildings2.2 U.S. Code of Federal Regulations324 CFR Part 35 Department of Housing and Urban Devel-opment (HUD), Requirements for Notification, Evaluati
12、onand Reduction of Lead-Based Paint Hazards in FederallyOwned Residential Property and Housing Receiving Fed-eral Assistance (especially subparts B and R)40 CFR Part 745 Environmental Protection Agency (EPA),Lead-Based Paint Poisoning Prevention in Certain Resi-dential Structures (especially subpart
13、s D, L and Q)1This practice is under the jurisdiction of ASTM Committee E06 on Perfor-mance of Buildings and is the direct responsibility of Subcommittee E06.23 on LeadHazards Associated with Buildings.Current edition approved Oct. 1, 2016. Published November 2016. DOI:10.1520/E3074_E3074M-16.2For r
14、eferenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Available from U.S. Government Publishing Office, 732 N. Capitol S
15、t., NW,Washington, DC 20401-0001, http:/www.gpo.gov.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States13. Terminology3.1 Definitions: For definitions of terms not appearing here,see Terminologies E631, E1480, and E1605.3.2 Definitions of
16、 Terms Specific to This Standard:3.2.1 clearance, ncombined visual and quantitative envi-ronmental evaluation used to determine if a hazardous level oflead remains after a lead hazard reduction, or other buildingmaintenance or modification activity has been performed.3.2.1.1 DiscussionUsually perfor
17、med with the idea ofdetermining if the space undergoing the evaluation is safe forreoccupancy.3.2.2 clearance area, nwork area and additional spacesoutside the work area where lead contamination may haveoccurred during lead hazard reduction and other buildingmaintenance or modification activities.3.
18、2.2.1 DiscussionThe spaces outside the work area mayinclude rooms connected to the work area, egress routes, wastestorage areas, and grounds adjoining exterior work areas.3.2.3 clearance examination, nthe process of conductinga combined visual and quantitative environmental evaluationused to determi
19、ne if a hazardous level of lead remains after alead hazard reduction, or other building maintenance or modi-fication activity has been performed.3.2.4 clearance level, nvalue, specified by regulationfrom an authority having jurisdiction or by contractualagreement, that indicates the maximum amount o
20、f lead permit-ted in dust on a surface following completion of a lead hazardreduction, or other building maintenance or modification ac-tivity.3.2.5 work area, nthe interior or exterior space where leadhazard control, or other building maintenance or modificationactivities are performed.3.2.5.1 Disc
21、ussionThe interior work space may include(1) a portion of a room, an entire room, or room equivalent, or(2) portions of multiple rooms, multiple rooms or roomequivalents, depending upon the extent or location, or both, ofthe lead hazard control activity. The exterior work space mayinclude (1) a port
22、ion of a building facade, an entire buildingfacade, associated structures, such as fences, and (2) bare soil.4. Significance and Use4.1 A clearance examination of abatement areas and otherareas associated with other lead-hazard control activities, orbuilding maintenance or modification activities in
23、 single-family detached dwellings, individual units in multifamilydwellings, common areas or exterior sites, and child-occupiedfacilities is performed to determine that the clearance area isadequately safe for reoccupancy.4.2 It is the responsibility of the user of this standard toassure that all re
24、gulatory, contractual and personnel require-ments are met prior to conduct of a clearance examination. Ata minimum, users of this standard shall be trained in its use andin safe practices for its conduct.NOTE 2Authorities having jurisdiction may have certification orspecific training requirements, o
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME3074E3074M2016STANDARDPRACTICEFORCLEARANCEEXAMINATIONSFOLLOWINGLEADHAZARDREDUCTIONACTIVITIESINSINGLEFAMILYDWELLINGSININDIVIDUALUNITSOFMULTIFAMILYDWELLINPDF

链接地址:http://www.mydoc123.com/p-532316.html