《ASTM E2694-2009 Standard Test Method for Measurement of Adenosine Triphosphate in Water-Miscible Metalworking Fluids《测定水溶性金属加工液中三磷酸腺苷的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM E2694-2009 Standard Test Method for Measurement of Adenosine Triphosphate in Water-Miscible Metalworking Fluids《测定水溶性金属加工液中三磷酸腺苷的标准试验方法》.pdf(7页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E 2694 09An American National StandardStandard Test Method forMeasurement of Adenosine Triphosphate in Water-MiscibleMetalworking Fluids1This standard is issued under the fixed designation E 2694; the number immediately following the designation indicates the year oforiginal adoption or
2、, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 The method provides a protocol for capturing, extract-ing and quantifying the a
3、denosine triphosphate (ATP) contentassociated with microorganisms found in water-miscible met-alworking fluids (MWF).1.2 The ATP is measured using a bioluminescence enzymeassay, whereby light is generated in amounts proportional tothe concentration of ATP in the samples. The light is producedand mea
4、sured quantitatively as relative light units (RLU)which are converted by comparison with an ATP standard andcomputation to pg ATP/mL.1.3 This method is equally suitable for use in the laboratoryor field.1.4 The method detects ATP concentrations in the range of4.0 pg ATP/mL to 400,000 pg ATP/mL.1.5 P
5、roviding interferences can be overcome, biolumines-cence is a reliable and proven method for qualifying andquantifying ATP. The method does not differentiate betweenATP from different sources, for example, from different typesof microorganisms, such as bacteria and fungi.1.6 The values stated in SI
6、are to be regarded as standard.1.7 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitatio
7、ns prior to use.2. Referenced Documents2.1 ASTM Standards:2D 1129 Terminology Relating to WaterD 4012 Test Method for Adenosine Triphosphate (ATP)Content of Microorganisms in WaterD 4840 Guide for Sample Chain-of-Custody ProceduresD 6161 Terminology Used for Microfiltration, Ultrafiltra-tion, Nanofi
8、ltration and Reverse Osmosis Membrane Pro-cessesE 1326 Guide for Evaluating Nonconventional Microbio-logical Tests Used for Enumerating BacteriaE 1497 Practice for Selection and Safe Use of Water-Miscible and Straight Oil Metal Removal FluidsE 2523 Terminology for Metalworking Fluids and Opera-tions
9、2.2 Government Standards:329 CFR 1910.1000 Occupational Safety and Health Stan-dards; Air contaminants29 CFR 1910.1450 Occupational Exposure to HazardousChemicals in Laboratories3. Terminology3.1 Definitions:For definition of terms used in this method, refer to Termi-nology standards D 1129, D 6161,
10、 and E 2523.3.2 adenosine triphosphate (ATP), na molecule com-prised of a purine and three phosphate groups that serves as theprimary energy transport molecule in all biological cells.3.3 adenosine monophosphate (AMP), nthe moleculeformed by the removal of two molecules of phosphate (onepyrophosphat
11、e molecule) from ATP.3.4 aseptic, adjsterile, free from viable microbial con-tamination.3.5 bioluminescence, nthe production and emission oflight by a living organism as the result of a chemical reactionduring which chemical energy is converted to light energy.3.6 biomass, nany matter which is or wa
12、s a livingorganism or excreted from a microorganism (D 6161).3.7 culturable, adjmicroorganisms that proliferate as in-dicated by the formation of colonies on solid growth media orthe development of turbidity in liquid growth media underspecific growth conditions.1This test method is under the jurisd
13、iction of ASTM Committee E34 onOccupational Health and Safety and is the direct responsibility of SubcommitteeE34.50 on Health and Safety Standards for Metal Working Fluids.Current edition approved May 1, 2009. Published June 2009.2For referenced ASTM standards, visit the ASTM website, www.astm.org,
14、 orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Available from U.S. Government Printing Office Superintendent of Documents,732 N. Capitol St., NW, Mail Stop: SDE, Washington, DC
15、 20401, http:/www.access.gpo.gov.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.3.8 Luciferase, na general term for a class of enzymesthat catalyze bioluminescent reactions.3.9 Luciferin, na general term for a class of light-emittin
16、gbiological pigments found in organisms capable of biolumi-nescence.3.10 luminometer, nan instrument capable of measuringlight emitted as a result of non-thermal excitation.3.11 relative light unit (RLU), nan instrument-specificunit of measurement reflecting the number of photons emittedby the Lucif
17、erin-Luciferase driven hydrolysis of ATP to AMPplus pyrophosphate.3.11.1 DiscussionRLU is not an SI unit, however, RLUare proportional to ATP concentration.3.12 viable microbial biomass, nmetabolically active (liv-ing) microorganisms3.13 Acronyms:3.13.1 AMPadenosine monophosphate3.13.2 ATPadenosine
18、triphosphate3.13.3 HDPEhigh density polyethylene3.13.4 MWFmetalworking fluid3.13.5 PPpolypropylene3.13.6 RLUrelative light unit4. Summary of Test Method4.1 A control assay is performed using 100 L of 1.0 ngATP/mL standard.4.2 A 5.0 mL sample of MWF is placed into a syringe andthen pressure- filtered
19、 through a 0.7 m, glass-fiber, in-linedepth filter.4.3 The retentate is then washed with a reagent to removeextra-cellularATP and other contaminants that might otherwiseinterfere with the ATP assay.4.4 The filter is air-dried.4.5 A lysing reagent is used to release ATP from microbialcells that have
20、been captured on the glass-fiber filter, and thefiltrate is dispensed into an unused culture tube.4.6 The filtrate is diluted 1+9 with a buffer solution.4.7 A 100-L volume of diluted filtrate is transferred to anunused culture tube into which 100 L of Luciferin-Luciferasereagent has previously been
21、dispensed.4.8 The culture tube is placed into a luminometer and thelight intensity is read in RLU.4.9 RLU are converted to Log10pg ATP/mL of sample bycomputation.5. Significance and Use5.1 This method measures the concentration of ATP presentin the sample. ATP is a constituent of all living cells, i
22、ncludingbacteria and fungi. Consequently, the presence of ATP is anindicator of total microbial contamination in metalworkingfluids. ATP is not associated with matter of non-biologicalorigin.5.2 Method D 4012 validated ATP as a surrogate for cultur-able bacterial data (Guide E 1326).5.3 This method
23、differs from Method D 4012 in that iteliminates interferences that have historically rendered ATPtesting unusable with complex organic fluids such as MWF.5.4 The ATP test provides rapid test results that reflect thetotal bioburden in the sample. It thereby reduces the delaybetween test initiation an
24、d data capture, from the 36 h to 48 h(or longer) required for culturable colonies to become visible,to approximately five minutes.5.5 Although ATP data covary strongly with culture data inMWF4, different factors affect ATP concentration than thosethat affect culturability.5.5.1 Culturability is affe
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME26942009STANDARDTESTMETHODFORMEASUREMENTOFADENOSINETRIPHOSPHATEINWATERMISCIBLEMETALWORKINGFLUIDS

链接地址:http://www.mydoc123.com/p-531713.html