ASTM D3201-2008ae1 Standard Test Method for Hygroscopic Properties of Fire-Retardant Wood and Wood-Based Products《防火木材和木制品吸湿特性的标准试验方法》.pdf
《ASTM D3201-2008ae1 Standard Test Method for Hygroscopic Properties of Fire-Retardant Wood and Wood-Based Products《防火木材和木制品吸湿特性的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D3201-2008ae1 Standard Test Method for Hygroscopic Properties of Fire-Retardant Wood and Wood-Based Products《防火木材和木制品吸湿特性的标准试验方法》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 3201 08a1Standard Test Method forHygroscopic Properties of Fire-Retardant Wood and Wood-Based Products1This standard is issued under the fixed designation D 3201; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the y
2、ear of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1NOTENote 2 was editorially added in October 2009.1. Scope1.1 This test method prescribes the procedure for determin-ing th
3、e moisture content of fire-retardant-treated wood andwood-based product samples after exposure to a standard highrelative humidity condition of 92 6 2 % at 27 6 2C(81 6 4F).1.2 The text of this test method references notes andfootnotes which provide explanatory material. These notes andfootnotes (ex
4、cluding those in tables and figures) shall not beconsidered as requirements of this test method.1.3 The values stated in SI units are to be regarded as thestandard. The inch-pound values given in parentheses are forinformation only and are not considered standard.1.4 This standard does not purport t
5、o address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D9 Termi
6、nology Relating to Wood and Wood-Based Prod-uctsE 176 Terminology of Fire Standards3. Terminology3.1 DefinitionsDefinitions used in this practice are inaccordance with Terminologies D9and E 176.4. Significance and Use4.1 The hygroscopic properties of wood and wood-basedproducts treated with fire-ret
7、ardant chemicals are often greaterthan for untreated products. This is particularly true at thehigher relative humidity conditions. This higher hygroscopicitysometimes is the cause for staining, decay, poor paint adhesion,and migration and exuding of chemicals and moisture at thehigh humidities. Cor
8、rosion of metal fasteners sometimes alsooccurs.4.2 The results obtained with this standard are important inidentifying treatments with low hygroscopic properties.4.3 Results can be useful in determining exposure limita-tions in service for specific treated products.4.4 Building codes and other speci
9、fications for fire-retardant-treated wood for interior use include requirementsbased on this test method.5. Apparatus5.1 Conditioning chamber with air circulation and capableof being maintained at 27 6 2C (81 6 4F) and a relativehumidity of 92 6 2%.5.2 Oven, air-circulated and vented, capable of mai
10、ntaininga temperature of 103 6 2C (217 6 4F).5.3 Weighing ScaleA scale or balance that will weigh aspecimen within an accuracy of 60.2 %.6. Test Specimens6.1 A minimum of five specimens shall be selected thatrepresent the lot. Unless otherwise specified, specimens shallbe full cross sections, no les
11、s than 25.4 mm (1 in.) along thegrain, but longer as needed to provide a minimum volume of33 000 mm3(2 in.3).6.2 The specimens shall be penetrated by the fire-retardantchemical to be representative for the treated product.NOTE 1The use of untreated specimens as control specimens isrecommended to pro
12、vide verification of the high-humidity conditionsused.1This test method is under the jurisdiction of ASTM Committee D07 on Woodand is the direct responsibility of Subcommittee D07.07 on Fire Performance ofWood.Current edition approved Nov. 1, 2008. Published December 2008. Originallyapproved in 1973
13、. Last previous edition approved in 2008 as D 3201 08.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1Copyri
14、ght ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.7. Procedure7.1 All measurements of the specimen weight shall be to anaccuracy of 60.2 %.7.2 The specimens shall be in moisture equilibrium with alaboratory ambient condition of 30 to 65 % rel
15、ative humidity orshall be exposed for at least 7 days at such a condition prior tohigh-humidity exposure.7.3 If the specimens will support fungal or mold growthduring the high humidity exposure, then the specimens shall besprayed with a suitable biocide just prior to the above exposureand allowed to
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD32012008AE1STANDARDTESTMETHODFORHYGROSCOPICPROPERTIESOFFIRERETARDANTWOODANDWOODBASEDPRODUCTS 防火

链接地址:http://www.mydoc123.com/p-514297.html