ASTM E2119-2016 Standard Practice for Quality Systems for Conducting In Situ Measurements of Lead Content in Paint or Other Coatings Using Field-Portable X-Ray Fluorescence (XRF) D.pdf
《ASTM E2119-2016 Standard Practice for Quality Systems for Conducting In Situ Measurements of Lead Content in Paint or Other Coatings Using Field-Portable X-Ray Fluorescence (XRF) D.pdf》由会员分享,可在线阅读,更多相关《ASTM E2119-2016 Standard Practice for Quality Systems for Conducting In Situ Measurements of Lead Content in Paint or Other Coatings Using Field-Portable X-Ray Fluorescence (XRF) D.pdf(7页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E2119 16Standard Practice forQuality Systems for Conducting In Situ Measurements ofLead Content in Paint or Other Coatings Using Field-Portable X-Ray Fluorescence (XRF) Devices1This standard is issued under the fixed designation E2119; the number immediately following the designation in
2、dicates the year oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This practice covers the collection and
3、documentation ofquality control (QC) measurements for determining acceptablelevels of instrumental performance when using field-portableenergy-dispersive x-ray fluorescence spectrometry devices(XRFs) for the purposes of generating lead classificationresults from measurements on paint and other coati
4、ng filmswithin buildings and related structures.1.2 QC procedures covered in this provisional practiceinclude the performance of calibration checks, substrate biaschecks, and specific instructions for documenting the collecteddata for later use in reporting the results.1.3 No detailed operating inst
5、ructions are provided becauseof differences among the various makes and models of suitableinstruments. Instead, the analyst is to follow the instructionsprovided by the manufacturer of the particular XRF device orother relevant sources of information on XRF operation.1.4 This practice contains notes
6、 which are explanatory andare not part of the mandatory requirements of this provisionalpractice.1.5 The values stated in SI units are to be regarded asstandard. No other units of measurement are included in thisstandard.1.6 This standard does not purport to address all of thesafety concerns, if any
7、, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory requirements prior to use.2. Referenced Documents2.1 ASTM Standards:2E1583 Practice for Evaluating Laboratories Engaged
8、 in theDetermination of Lead in Paint, Dust, AirborneParticulates, and Soil Taken From and Around Buildingsand Related Structures (Withdrawn 1998)3E1605 Terminology Relating to Lead in BuildingsE1613 Test Method for Determination of Lead by Induc-tively Coupled Plasma Atomic Emission Spectrometry(IC
9、P-AES), Flame Atomic Absorption Spectrometry(FAAS), or Graphite Furnace Atomic Absorption Spec-trometry (GFAAS) TechniquesE1645 Practice for Preparation of Dried Paint Samples byHotplate or Microwave Digestion for Subsequent LeadAnalysisE1729 Practice for Field Collection of Dried Paint Samplesfor S
10、ubsequent Lead Determination2.2 HUD Document:4Guidelines for the Evaluation and Control of Lead-BasedPaint Hazards in Housing, 2nd Edition, July 20123. Terminology3.1 DefinitionsFor definition of terms not presentedbelow, refer to Terminology E1605.3.2 Definitions of Terms Specific to This Standard:
11、3.2.1 building component, npart or element of a buildingthat is made of an industry product that is manufactured as anindependent unit and is capable of being joined with otherelements. Examples include doors, walls, baseboard and exte-rior siding.1This practice is under the jurisdiction of ASTM Com
12、mittee E06 on Perfor-mance of Buildings and is the direct responsibility of Subcommittee E06.23 on LeadHazards Associated with Buildings.Current edition approved March 1, 2016. Published April 2016. Originallypublished as PS 95-98. Last previous edition approved in 2000 as E2119-00 whichwas withdraw
13、n January 2009 and reinstated in March 2016. DOI: 10.1520/E2119-16.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM we
14、bsite.3The last approved version of this historical standard is referenced onwww.astm.org.4Available from U.S. Department of Housing and Urban Development, 451 7thStreet, SW, Washington, DC 20410, http:/www.hud.gov.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken,
15、PA 19428-2959. United States13.2.2 calibration check, na procedure that generates a QCmeasurement using a calibration test sample with one type ofcontrol block (usually wood).3.2.3 calibration mode, na selected operating mode thatpermits adjustment of an instruments calibration.3.2.4 calibration tes
16、t sample, na test film sample of aknown lead level in mg/cm2, which must have a reporteduncertainty of the lead level. Calibration test samples may beseparate from a substrate or adhered to a substrate. Allcalibration test samples shall be traceable to the NationalInstitute of Standards and Technolo
17、gy (NIST) standard refer-ence materials or other national or international standardreference materials and have a known specified uncertainty inthe known lead level.3.2.5 continuing calibration check, na calibration checkperformed during the testing day after the initial calibrationcheck. A continui
18、ng calibration check also can serve as a finalcalibration check.3.2.6 control block, na small block of material of anidentifiable substrate type used to simulate a building materialduring QC measurements.3.2.7 display unit, nan electronic device that presents theresults of an XRF measurement to the
19、user. Other parameterssuch as total measurement time also may be presented.3.2.8 final calibration check, nthe last calibration checkperformed in a testing period.3.2.9 inconclusive lead classification result, na lead clas-sification result that reliably cannot be expressed, for example,reported, as
20、 either containing lead (positive) or not containinglead (negative) at or above an appropriate local, state, orfederal action level for lead in coatings. Such results com-monly are referred to and reported as “inconclusive” results,for example, the XRF measurement that cannot determinewhether lead i
21、s or is not present at or above an appropriatelocal, state, or federal action level for lead in coatings.3.2.10 initial calibration check, nthe first calibrationcheck of the testing period performed after the XRF instrumenthas been turned on and allowed to warm up.3.2.11 lead classification result,
22、nan XRF measurementexpressed, for example, as either positive-for-lead, or negative-for-lead, at or above and appropriate local, state, or federalaction level for lead in coatings.Anegative-for-lead result doesnot mean there is no lead present. For some makes and modelsof XRF instruments, lead measu
23、rement values obtained near anappropriate local, state or federal action level for lead incoatings may generate inconclusive lead classification results.3.2.12 nominal read time, na read time that results whenthe radioactive source normally provided by the manufacturerfor that XRF instrument is at i
24、ts original source strength.3.2.13 operating mode, none or more settings that definethe operating parameters of an XRF instrument. Some XRFinstruments have multiple settings for use under differenttesting situations, for example, substrates, time or testingobjectives.3.2.14 power-down, nan event whe
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME21192016STANDARDPRACTICEFORQUALITYSYSTEMSFORCONDUCTINGINSITUMEASUREMENTSOFLEADCONTENTINPAINTOROTHERCOATINGSUSINGFIELDPORTABLEXRAYFLUORESCENCEXRFDPDF

链接地址:http://www.mydoc123.com/p-530321.html