ASTM E1909-2011 Standard Guide for Time-Intensity Evaluation of Sensory Attributes《感官属性时间序列评估的标准指南》.pdf
《ASTM E1909-2011 Standard Guide for Time-Intensity Evaluation of Sensory Attributes《感官属性时间序列评估的标准指南》.pdf》由会员分享,可在线阅读,更多相关《ASTM E1909-2011 Standard Guide for Time-Intensity Evaluation of Sensory Attributes《感官属性时间序列评估的标准指南》.pdf(16页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E1909 11Standard Guide forTime-Intensity Evaluation of Sensory Attributes1This standard is issued under the fixed designation E1909; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A number i
2、n parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This guide covers procedures for conducting and ana-lyzing time-intensity (T-I) evaluations of products or othersensory stimuli. Time-intensity
3、 is the measurement of theintensity of a single sensory sensation over time in response toa single exposure to a product or other sensory stimulus.Simultaneous evaluations of multiple sensory attributes arepossible, although are outside of the scope of this document.See bibliography for more informa
4、tion.1.2 This guide utilizes a specially trained panel to measurethe intensity of a single continuous sensation during the timefrom initial exposure:1.2.1 To its extinction,1.2.2 To a specified intensity, or1.2.3 To a predetermined limit of time.1.3 Applications not covered in this guide include mea
5、sur-ing:1.3.1 Multiple sensations,1.3.2 Multiple exposures within a single measurement, and1.3.3 Qualitative or hedonic changes in the perceived sen-sation.1.4 This guide includes protocols for the selection andtraining of judges, descriptions and use of physical datacollection devices, and methods
6、of data handling, summariza-tion, and statistical analysis. Illustration of two different datahandling and analysis approaches are included in the appen-dixes.1.5 This guide is not applicable to measure product shelf lifeor stability that require evaluations at discrete time intervals.1.6 This stand
7、ard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 AS
8、TM Standards:2E253 Terminology Relating to Sensory Evaluation of Ma-terials and Products3. Terminology3.1 Definitions of Terms Specific to This Standard: See Fig.1.3.1.1 area after Imaxpost-peak area under the curve.3.1.2 area before Imaxpre-peak area under the curve.3.1.3 AUCarea under the curve.3.
9、1.4 Imaxor peak intensitymaximum observed intensityduring the time of measurement.3.1.5 perimetermeasured distance of perimeter of areadelineated by T-I curve.3.1.6 plateau timeduration of peak intensity.3.1.7 rate of increaserate of intensity increase beforepeak intensity (slope).3.1.8 rate of decr
10、easerate of intensity decrease after peakintensity (slope).3.1.9 Tduror duration timetime from onset of sensationuntil it can no longer be perceived (TextTonset).3.1.10 Textor time to extinctiontime from initial exposureto the stimulus (Tinit) until it can no longer be perceived.3.1.11 Tinittime of
11、initial exposure to the stimulus, typi-cally when the clock starts.3.1.12 Tmaxtime to reach maximum intensity of the sen-sation after exposure to the stimulus.3.1.13 Tonsettime point when the stimulus is first per-ceived after initial exposure to the stimulus.3.1.14 Ttrunor truncated timetime until
12、a specified mini-mum intensity or until a pre-determined time point has beenreached.3.2 The graphical illustration of a typical time-intensitycurve is shown in Fig. 1. The time increment may be seconds,1This guide is under the jurisdiction of ASTM Committee E18 on SensoryEvaluation and is the direct
13、 responsibility of Subcommittee E18.03 on SensoryTheory and Statistics.Current edition approved April 1, 2011. Published May 2011. Originallyapproved in 1997. Last previous edition approved in 2003 as E1909 97 (2003).DOI: 10.1520/E1909-11.2For referenced ASTM standards, visit the ASTM website, www.a
14、stm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.minutes
15、, hours, etc., depending upon the characteristic of theparticular material under study.4. Summary of Guide4.1 This guide describes procedures utilizing speciallytrained panelists to measure the intensity of a single sensorysensation as it changes with time and the possible approachesto collect and a
16、nalyze such data. Details on specific proceduresare given in Sections 6-9 of this guide. Examples of time-related evaluations are included in the Appendixes.5. Significance and Use5.1 The purpose of time-intensity measurements is to estab-lish the pattern of development and decline of a particularse
17、nsory characteristic under study. T-I evaluations are appli-cable when measurements at a single time point (an averagingprocess) are not sufficient to distinguish products that havevery different temporal characteristics. As pointed out by Leeand Pangborn (1)3, “This averaging process results in the
18、masking or complete loss of important information such as rateof onset of stimulation, time and duration of maximumintensity, rate of decay of perceived intensity, time of extinc-tion, and total duration of the entire process.”5.2 Products rated similarly using traditional single pointtechniques of
19、product profiling may provide very differenttemporal sensory experiences to the consumer.Acceptability ofthe product may be affected, and traditional descriptive meth-odology does not reflect the changes in an attributes intensityover time.5.3 T-I has applications for a variety of products. Examples
20、include: food products, ranging from short-term sweetness in abeverage to long-term elasticity in chewing gum; personal careproducts, measuring the development and longevity of sham-poo lather and the residual skin feel of a skin cream; householdcare products, monitoring the intensity of scents over
21、 time;pharmaceuticals, monitoring skin cooling after application of atopical analgesic. Auditory signals or visual changes in prod-ucts can also be evaluated by the T-I technique.6. Time-Intensity Panel Selection and Training6.1 Screening and Selection of Panelists6.1.1 Time-Intensity evaluation is
22、a specialized type ofdescriptive analysis. Therefore, use of randomly selected,naive panelists is neither appropriate nor recommended. Pan-elists selected for Time-Intensity studies are screened asrecommended for other descriptive methods (see STP 758 (2).Use of panelists with previous descriptive t
23、raining facilitatesthe T-I training because these panelists are competent in bothrecognizing and intensity scaling an attribute.6.1.2 The goal of the selection process is to identifypanelists who have the ability to:6.1.2.1 Continually focus on a single sensory attribute,6.1.2.2 Accurately identify
24、and quantify a single sensoryattribute within a simple or complex sample,6.1.2.3 Accurately record changes in sensations as theyoccur,6.1.2.4 Perform consistently,6.1.2.5 Perform all test procedures with appropriate motorskills (for example, ability to chew gum while manipulating theinput device to
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME19092011STANDARDGUIDEFORTIMEINTENSITYEVALUATIONOFSENSORYATTRIBUTES 感官 属性 时间 序列 评估 标准 指南 PDF

链接地址:http://www.mydoc123.com/p-529769.html