ASTM E1908-2010 Standard Guide for Sample Selection of Debris Waste from a Building Renovation or Lead Abatement Project for Toxicity Characteristic Leaching Procedure (TCLP) Testi.pdf
《ASTM E1908-2010 Standard Guide for Sample Selection of Debris Waste from a Building Renovation or Lead Abatement Project for Toxicity Characteristic Leaching Procedure (TCLP) Testi.pdf》由会员分享,可在线阅读,更多相关《ASTM E1908-2010 Standard Guide for Sample Selection of Debris Waste from a Building Renovation or Lead Abatement Project for Toxicity Characteristic Leaching Procedure (TCLP) Testi.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E1908 10Standard Guide forSample Selection of Debris Waste from a BuildingRenovation or Lead Abatement Project for ToxicityCharacteristic Leaching Procedure (TCLP) Testing forLeachable Lead (Pb)1This standard is issued under the fixed designation E1908; the number immediately following
2、the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This guide describes a
3、 method for selecting samples ofbuilding components coated with paints suspected of contain-ing lead. The samples are collected from the debris wastestream created during demolition, renovation, lead hazardcontrol, or abatement projects. The samples are subsequentlyanalyzed in the laboratory for lea
4、d.1.1.1 The debris waste stream is assumed to have more thanone painted component, for example, metal doors, wood doors,and wood window trim.1.2 This guide is intended for use when sampling to test forlead only and does not include sampling considerations forother metals or for organic compounds. Th
5、is guide also doesnot include consideration of sampling for determination ofother possible hazardous characteristics of the waste.1.3 This guide assumes that the individual component typescomprising the debris waste stream are at least partiallysegregated and that the volume of each type of componen
6、t inthe debris waste stream may be estimated.1.4 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regula
7、tory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D4840 Guide for Sample Chain-of-Custody ProceduresE105 Practice for Probability Sampling of MaterialsE2239 Practice for Record Keeping and Record Preserva-tion for Lead Hazard Activities2.2 Federal Documents:340 CFR 261 Appendi
8、x II-Method 1311, Toxicity Character-istic Leaching Procedure (TCLP)2.3 OSHA Standard:429 CFR 1926.62 OSHA Lead in Construction Standard3. Terminology3.1 Definitions of Terms Specific to This Standard:3.1.1 component (of the waste), neach of those differentand distinguishable materials that comprise
9、 the waste.3.1.2 sample (of the waste), na collection of the compo-nents of the waste assembled in proportion to their contributionto the total volume of the waste.3.1.3 waste, nmaterial resulting from conduct of a demo-lition, renovation, or lead abatement project that is or will bedirected for dis
10、posal.3.1.4 waste stream, nthe total flow of waste from ademolition, renovation, lead hazard control or abatementproject.NOTE 1Regulations promulgated by authorities having jurisdictionmay define terms in 3.1.1-3.1.4 differently than defined above.4. Summary of Practice4.1 The entirety of the debris
11、 waste stream created bydemolition, renovation, lead hazard control or abatementprojects in and around buildings and related structures isexamined visually, and estimates made of the total volume ofthe waste and of the relative volume proportions of the variouscomponents of the waste.Asample of the
12、waste is selected andassembled that contains the various waste components in thesame relative volume proportions as these estimates. The1This guide is under the jurisdiction of ASTM Committee E06 on Performanceof Buildings and is the direct responsibility of E06.23 on Lead Hazards Associatedwith Bui
13、ldingsCurrent edition approved Oct. 1, 2010. Published November 2010. Originallyapproved in 1997. Last previous addition approved in 2003 as E1908 03. DOI:10.1520/E1908-10.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For An
14、nual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Available from U.S. Government Printing Office Superintendent of Documents,732 N. Capitol St., NW, Mail Stop: SDE, Washington, DC 20401, http:/www.access.gpo.gov.4Available from Occupation
15、al Safety and Health Administration (OSHA), 200Constitution Ave., NW, Washington, DC 20210, http:/www.osha.gov.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.sample is then submitted to a laboratory for conduct of theToxicity Charac
16、teristic Leaching Procedure (TCLP) for lead inaccordance with 40 CFR 261.5. Significance and Use5.1 Waste samples collected using this guide provide repre-sentative samples for analysis in a laboratory using the TCLP.5.2 The TCLP is used to simulate the transfer of lead fromburied lead-containing wa
17、ste into the ground water systemupon codisposal of the lead-containing waste and municipalsolid waste in unlined solid-waste landfills. The TCLP attemptsto simulate rain or ground water leaching, or both. For theprocedure to yield a predictor of the subsurface (in-ground)leaching process, a represen
18、tative sample of the volume of thewaste must be selected and submitted for leaching and analy-sis. The result of the sampling, leaching, and analysis processis used to determine the waste handling and disposal protocolsto be followed and to document compliance with applicablelaws, regulations, and r
19、equirements. The guide addresses thesampling process by defining a component-volume-basedmethod to collect and assemble a representative sample of asolid waste stream that may contain heterogeneous compo-nents.5.3 The collection of a volume-based sample of the wastestream is based on the fact that t
20、he TCLP leachate leadconcentration limit, like other such TCLP limits, was devel-oped based on the spatial dimensions of landfills.5.4 Individuals who use this guide are expected to be trainedin the proper and safe conduct of sampling of lead-containingwastes, qualified/certified/licensed as require
21、d by those au-thorities having jurisdiction over such activities, and properlyutilize tools and safety equipment when conducting theseprocedures.5.5 This guide may involve use of various hand and powertools for sampling the components of the waste. It is intendedthat such tools should be properly an
22、d safely used by personstrained and familiar with their performance and use.5.6 In general terms, building components are drilled tocollect samples of the various components in proportion to thevolume of those components in the entire building. Thecomponent samples are assembled, and the resulting a
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME19082010STANDARDGUIDEFORSAMPLESELECTIONOFDEBRISWASTEFROMABUILDINGRENOVATIONORLEADABATEMENTPROJECTFORTOXICITYCHARACTERISTICLEACHINGPROCEDURETCLPTESTIPDF

链接地址:http://www.mydoc123.com/p-529766.html