ASTM E1897-2014 Standard Practice for Measuring and Compensating for Transmittance of an Attenuating Medium Using Infrared Imaging Radiometers《采用红外成像辐射仪测量和均衡衰减介质的传输性的标准试验方法》.pdf
《ASTM E1897-2014 Standard Practice for Measuring and Compensating for Transmittance of an Attenuating Medium Using Infrared Imaging Radiometers《采用红外成像辐射仪测量和均衡衰减介质的传输性的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM E1897-2014 Standard Practice for Measuring and Compensating for Transmittance of an Attenuating Medium Using Infrared Imaging Radiometers《采用红外成像辐射仪测量和均衡衰减介质的传输性的标准试验方法》.pdf(6页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E1897 97 (Reapproved 2010)E1897 14Standard Test Methods Practice forMeasuring and Compensating for Transmittance of anAttenuating Medium Using Infrared Imaging Radiometers1This standard is issued under the fixed designation E1897; the number immediately following the designation indicat
2、es the year oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 These test methods cover procedures for measu
3、ring and compensating for transmittance when using an infrared imagingradiometer to measure the temperature of a specimen through an attenuating medium, such as a window, filter or atmosphere.1.2 The values stated in SI units are to be regarded as the standard.1.3 These test methods may involve use
4、of equipment and materials in the presence of heated or electrically-energizedequipment, or both.1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibilityof the user of this standard to establish appropriate safety and health
5、practices and determine the applicability of regulatorylimitations prior to use.2. Referenced Documents2.1 ASTM Standards:2E1316 Terminology for Nondestructive Examinations3. Terminology3.1 Definitions of Terms Specific to This Standard:3.1.1 attenuating mediuma semi-transparent solid, liquid or gas
6、, such as a window, filter, external optics or an atmosphere thatattenuates radiation.3.1.2 blackbody simulatora device with an emissivity close to 1.00 that can be heated or cooled to a stable temperature.3.1.3 filtera semi-transparent material that attenuates certain wavelengths of radiation.3.1.4
7、 infrared thermographerthe person using an infrared imaging radiometer.3.1.5 reflected temperaturethe temperature of the energy incident upon and reflected by the measurement surface of thespecimen.3.1.6 windowa semi-transparent material that separates conditioned and unconditioned atmospheres and a
8、ttenuates certainwavelengths of radiation.3.2 See also Terminology E1316.4. Summary of Test Method4.1 Using the computer built into an infrared imaging radiometer, a method is given for measuring the transmittance of anattenuating medium.4.2 Using the computer built into an infrared imaging radiomet
9、er, a method is given for compensating for errors whenmeasuring the temperature of a specimen through an attenuating medium when the emissivity of the specimen and thetransmittance of the attenuating medium are known.1 These test methods are This practice is under the jurisdiction ofASTM Committee E
10、07 on Nondestructive Testing and is the direct responsibility of Subcommittee E07.10on Specialized NDT Methods.Current edition approved June 15, 2010Dec. 1, 2014. Published November 2010December 2014. Originally approved 1997. Last previous edition approved 2002 in 2010as E1897 97 (2002)(2010).1. DO
11、I: 10.1520/E1897-97R10.10.1520/E1897-14.3 For referencedASTM standards, visit theASTM website, www.astm.org, or contactASTM Customer Service at serviceastm.org. For Annual Book of ASTM Standardsvolume information, refer to the standards Document Summary page on the ASTM website.This document is not
12、an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Becauseit may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate.
13、 In all cases only the current versionof the standard as published by ASTM is to be considered the official document.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States14.3 Using the computer built into an infrared imaging radiometer, a m
14、ethod is given for measuring and compensating forunknown transmittance and emissivity errors when the specimen temperature is known.5. Significance and Use5.1 The transmittance of an attenuating medium can cause errors for an infrared thermographer using an infrared imagingradiometer to measure the
15、temperature of a specimen through the medium. Three test methods are given for measuring andcompensating for this error source.5.1.1 A test method is given for measuring the transmittance of an attenuating medium.5.1.2 A test method is given for compensating for errors when measuring the temperature
16、 of a specimen having a knownemissivity through an attenuating medium with a known transmittance.5.1.3 A test method is given for measuring and compensating for transmittance and emissivity errors when the specimentemperature is known.5.2 These test methods can be used in the field or laboratory usi
17、ng commonly available materials.5.3 These test methods can be used with any infrared radiometers that have the required computer capabilities.6. Interferences6.1 Test Method for Measuring the Transmittance of an Attenuating Medium:6.1.1 This test method requires a blackbody simulator with an emissiv
18、ity of 0.95 or greater that is at least 20C warmer thanambient temperature. Potential errors can be minimized by ensuring the stability of the temperature difference between the sourceand the ambient temperature during the test. Also, the transmittance measurement accuracy can be increased by increa
19、sing thistemperature difference.6.1.2 Errors can be minimized by ensuring that the temperature of the attenuating medium is as close as possible to the reflectedtemperature incident upon the specimen.6.1.3 The compositions and thicknesses of attenuating media can vary within the same specimen. Error
20、s can be minimized bymeasuring through the same portion of the specimen every time.6.2 Test Method for Compensating for Unknown Errors When Measuring the Temperature of a Specimen With a KnownEmissivity Through an Attenuating Medium Having a Known Transmittance:6.2.1 Errors can be minimized by ensur
21、ing that the temperature of the attenuating medium is as close as possible to the reflectedtemperature incident upon the specimen.6.3 The transmittance of an attenuating medium may be specific to the temperature of the medium and the spectral wavebandof the radiometer used to make the measurement. T
22、herefore, the temperature of the measured specimen and the spectral wavebandof the radiometer used should be noted with the measured transmittance value.6.4 The use of these test methods to compensate for the transmittance of an attenuating medium is valid only when measuringthe temperatures of spec
23、imens that are opaque in the waveband of the infrared imaging radiometer.7. Apparatus7.1 A calibrated infrared imaging radiometer with a built-in computer that allows the infrared thermographer to input reflectedtemperatures and emissivity values.7.2 The test method for measuring the transmittance o
24、f an attenuating medium requires a tripod or device to support the infraredimaging radiometer.7.3 The test method for measuring the transmittance of an attenuating medium requires a high-emissivity source that is heatedto a stable temperature at least 20C above ambient temperature.7.4 The test metho
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME18972014STANDARDPRACTICEFORMEASURINGANDCOMPENSATINGFORTRANSMITTANCEOFANATTENUATINGMEDIUMUSINGINFRAREDIMAGINGRADIOMETERS

链接地址:http://www.mydoc123.com/p-529753.html