ASTM E1673-1996(2006) Standard Test Method for Percent Suspensibility《百分比悬浮度标准试验方法》.pdf
《ASTM E1673-1996(2006) Standard Test Method for Percent Suspensibility《百分比悬浮度标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM E1673-1996(2006) Standard Test Method for Percent Suspensibility《百分比悬浮度标准试验方法》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E 1673 96 (Reapproved 2006)Standard Test Method forPercent Suspensibility1This standard is issued under the fixed designation E 1673; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A number
2、in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method is used to determine the percentsuspensibility of dry pesticide formulations.1.2 This standard does not purport to address a
3、ll of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use. For specificprecautionary statements see Section 7.2. Referen
4、ced Documents2.1 ASTM Standards:2D 1126 Test Method for Hardness in WaterD 1193 Specification for Reagent Water3. Summary of Test Method3.1 Aknown quantity of dry pesticide is slurried into 50 mLof test water in a 100-mL beaker. The slurry is quantitativelytransferred to a 250-mL mixing cylinder usi
5、ng additional testwater to rinse the beaker. The 250-mL mixing cylinder is thenfilled to volume with test water. The mixing cylinder isstoppered and inverted 15 complete cycles. The mixing cylin-der is allowed to stand for 30 min.After 30 min the top 225 mLis drawn off and the remaining suspension i
6、s dried. The residueweight will determine the percent suspensibility.4. Significance and Use4.1 This test method is designed specifically for dry formu-lations, but need not be restricted to these materials.4.2 Either option of this test method (see Section 8) may beused to determine the percent sus
7、pensibility.4.3 This test method may not be applicable to all dryformulations such as those containing either liquids or ingre-dients that rise to the top upon separation.4.4 This test method may not be applicable to formulationscontaining ingredients that decompose under the test condi-tions.4.5 Th
8、is test method may not give reproducible results ifflocculation occurs.4.6 This test method should be run in duplicate.4.7 Products containing water soluble or volatile compo-nents may result in errors.5. Apparatus5.1 Balance, top loading, with an accuracy of 60.01g orbetter.5.2 Beaker, 100 mL.5.3 M
9、ixing Cylinder, stoppered, 250 mL, flat bottom, KI-MAX series 200393or equivalent.5.4 Timer, adjustable, with an accuracy of 6 min.5.5 Magnetic Stirrer, 120 to 1200 rpm, or equivalent.5.6 Stir Bar, magnetic 1 in. in length and38 in. in diameter(2.5 cm 3 1 cm).5.7 Weighing Dish, aluminum (57 3 18 mm)
10、 or petri dish,or equivalent.5.8 Vacuum Apparatus, see Fig. 1, equipped with a ventedstopper to prevent the formation of a vacuum.5.9 Filtering Flask, heavy wall, 500 mL, KIMAX Series270603or equivalent.5.10 Gravity Oven.5.11 Centrifuge, any centrifuge capable of holding a 50 mLor larger tube and ma
11、intaining a minimum speed of 1500 rpm.5.12 Centrifuge Tube, plastic or glass, 50 mL or larger.6. Reagents (Test Water)6.1 Purity of ReagentsReagent grade chemicals shall beused in all tests. Unless otherwise indicated, it is intended that1This test method is under the jurisdiction of ASTM Committee
12、E35 onPesticides and Alternative Control Agents and is the direct responsibility ofSubcommittee E35.22 on Pesticide Formulations and Delivery Systems.Current edition approved Nov. 15, 2006. Published December 2006. Originallyapproved in 1995. Last previous edition approved in 2001 as E 1673 96 (2001
13、).2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Available from Fisher Scientific, 711 Forbes Avenue, Pitts
14、burgh, PA 15219.Also available from Curtin Matheson Scientific, Inc., P.O. Box 1546, Houston, TX77251-1546.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.all reagents shall conform to the specifications of the Commit-tee on Analytic
15、al Reagents of the American Chemical Societywhere such specifications are available.46.2 Purity of WaterUnless otherwise indicated, referenceto water shall be understood to mean reagent water, Type IV, asdefined by Specification D 1193.NOTE 1Type IV grade reagent water may be prepared by distillatio
16、n,ion exchange, reverse osmosis, electrodialysis, or a combination thereof.6.3 Synthetic Hard Water StockTransfer 12.14 g of anhy-drous calcium chloride (CaCl2) and 5.55 g of magnesiumchloride hexahydrate (MgCl26H2O) to a 1000-mL volumetricflask. Dissolve the reagents with approximately 750 mL ofwat
17、er and equilibrate to 20C. Dilute the solution to 1000 mLtotal volume with water at 20C, stopper the flask and mix thesolution thoroughly. This mixture is equivalent to 13 680 ppmas calcium carbonate (CaCO3) and is based on a compositionalratio of 4:1 calcium carbonate to magnesium carbonate.6.3.1 S
18、oft WaterEquivalent to a total hardness of 34.2ppm as calcium carbonate (CaCO3). Transfer 2.50 mL ofsynthetic hard water stock by pipet to a 1000-mL volumetricflask and dilute to volume with water at 20C. Mix solutionthoroughly.NOTE 2It is recommended that total hardness be checked in accor-dance wi
19、th Test Method MT-73, CIPAC 1, EDTA titration.5An alternatemethod is provided in Test Method D 1126 where the value is representedas CaCO3. A value within 6 % of the nominal hardness value isacceptable.6.3.2 Hard WaterEquivalent to a total hardness of 342ppm as calcium carbonate (CaCO3). Transfer 25
20、 mL ofsynthetic hard water stock by buret to a 1000-mL volumetricflask and dilute to volume with water at 20C. Mix this solutionthoroughly (see Note 2).6.3.3 Extra-Hard WaterEquivalent to a total hardness of1000 ppm as calcium carbonate (CaCO3). Transfer 73.1 mL ofsynthetic hard water stock by buret
21、 to a 1000-mL volumetricflask and dilute to volume with water at 20C. Mix this solutionthoroughly (see Note 2).6.3.4 Other Test WatersOther synthetic waters can beprepared by using the following calculation:Desired Water Hardness 4 13.680 5millilitres of synthetic hard water stock at 20C to bedilute
22、d volumetrically to 1000 mL with water at 20C# (1)6.4 Other CarriersCarriers other than water may be usedwhen appropriate.7. Safety Precautions7.1 Before testing, read the precautionary statements on theproduct label or the Material Safety Data Sheet (MSDS), orboth. Take proper precautions to preven
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME167319962006STANDARDTESTMETHODFORPERCENTSUSPENSIBILITY 百分比 悬浮 标准 试验 方法 PDF

链接地址:http://www.mydoc123.com/p-529197.html