ASTM E1454-2002 Standard Guide for Data Fields for Computerized Transfer of Digital Ultrasonic Testing Data《数字超声波测试数据的计算机传送用数据段的标准指南》.pdf
《ASTM E1454-2002 Standard Guide for Data Fields for Computerized Transfer of Digital Ultrasonic Testing Data《数字超声波测试数据的计算机传送用数据段的标准指南》.pdf》由会员分享,可在线阅读,更多相关《ASTM E1454-2002 Standard Guide for Data Fields for Computerized Transfer of Digital Ultrasonic Testing Data《数字超声波测试数据的计算机传送用数据段的标准指南》.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E 1454 02Standard Guide forData Fields for Computerized Transfer of Digital UltrasonicExamination Data1This standard is issued under the fixed designation E 1454; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the yea
2、r of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This guide provides a listing and description of the fieldsthat are recommended for inclusion in a digital ultra
3、sonicexamination data base to facilitate the transfer of such data.This guide is prepared for use particularly with digital imagedata obtained from ultrasonic scanning systems. The fieldlisting includes those fields regarded as necessary for inclusionin the data base (as indicated by Footnote C in T
4、able 1); thesefields, so marked, are regarded as the minimum informationnecessary for a transfer recipient to understand the data. Inaddition, other optional fields are listed as a remainder of thetypes of information that may be useful for additional under-standing of the data, or applicable to a l
5、imited number ofapplications.1.2 It is recognized that organizations may have in place aninternal format for the storage and retrieval of ultrasonicexamination data. This guide should not impede the use of suchformats since it is probable that the necessary fields are alreadyincluded in such interna
6、l data bases, or that the few additionscan be made. The numerical Field Number listing indicated inthis guide is only for convenience; the specific numbers carryno inherent significance and are not a part of the data file.1.3 The types of ultrasonic examination systems that appearuseful in relation
7、to this guide include those described inPractices E 114, E 214 and E 1001. Many of the terms used aredefined in Terminology E 1316. The search unit parametersused in this guide follow from those used in Guide E 1065.1.4 This standard does not purport to address all of thesafety concerns, if any, ass
8、ociated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:E 114 Practice for Ultrasonic Pulse-Echo Straight-BeamExa
9、mination by the Contact Method2E 214 Practice for Immersed Ultrasonic Examination by theReflection Method Using Pulsed Longitudinal Waves2E 1001 Practice for Detection and Evaluation of Disconti-nuities by the Immersed Pulse-Echo Ultrasonic MethodUsing Longitudinal Waves2E 1065 Guide for Evaluating
10、Characteristics of UltrasonicSearch Units2E 1316 Terminology for Nondestructive Examinations23. Significance and Use3.1 The primary use of this guide is to provide a standard-ized approach for the data file to be used for the transfer ofdigital ultrasonic data from one user to another where the twou
11、sers are working with dissimilar ultrasonic systems. Thisguide describes the contents, both required and optional, for anintermediate data file that can be created from the native formatof the ultrasonic system on which the data was collected andthat can be converted into the native format of the re
12、ceivingultrasonic or data analysis system. The development of trans-lator software to accomplish these data format conversions isbeing addressed under a separate effort; this will includespecific items needed for the data transfer, for example,language used, memory requirements and intermediate spec
13、i-fication, including detailed data formats and structures. Thisguide will also be useful in the archival storage and retrieval ofultrasonic data as either a data format specifier or as a guide tothe data elements that should be included in the archival file.3.2 Although the recommended field listin
14、g includes morethan 120 items, only about one third of those are regarded asessential and marked with Footnote C in Table 1. Fields somarked must be addressed in the data base. The other recom-mended fields provide additional information that a user willfind helpful in understanding the ultrasonic e
15、xamination result.These header field items will, in most cases, make up only avery small part of an ultrasonic examination file. The actualstream of ultrasonic data that make up the image will take upthe largest part of the data base. Since an ultrasonic image filewill normally be large, the concept
16、 of data compression will beconsidered in many cases. Compressed data should be noted,1This guide is under the jurisdiction of ASTM Committee E07 on Nondestruc-tive Testing and is the direct responsibility of Subcommittee E07.11 on DigitalImaging and Communication in Nondestructive Evaluation (DICON
17、DE).Current edition approved July 10, 2002. Published September 2002. Originallypublished as E 1454 92. Last previous edition E 1454 92(97).2Annual Book of ASTM Standards, Vol 03.03.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.alo
18、ng with a description of the compression method, asindicated in Field No. 122.3.3 This guide describes the structure of a data file for all ofthe ultrasonic information collected in a single scan. Somesystems record multiple examination results during a singlescan. For example, through transmission
19、attenuation data aswell as pulse echo thickness data may be recorded at the sametime. These data may be stored in separate image planes; seeField No. 102. In other systems, complete digitized waveformsmay be recorded at each examination point. It is recognizedthat the complete examination record may
20、 contain several files,for example, for the same examination method in differentobject areas, with or without image processing, for differentexamination methods (through-transmission, pulse-echo, ra-diologic, infrared, etc.) collected during the same or duringdifferent scan sessions, and for variati
21、ons within a singlemethod (frequency change, etc.). Information about the exist-ence of other images/examination records for the examinedobject should be noted in the appropriate fields. A single imageplane may be one created by overlaying or processing resultsfor multiple examination approaches, fo
22、r example data fusion.For such images, the notes sections must clearly state how theimage for this file was created.TABLE 1 Field ListingField NumberAField Name and Description Data Type/UnitsBHeader Information:1CIntermediate file name Alphanumeric stringD2CFormat revision code Alphanumeric string3
23、CFormat revision date yyyy/mm/ddD4CSource file name Alphanumeric string5 Examination file description notes Alphanumeric string6CExamining company and location Alphanumeric stringD7CExamination date yyyy/mm/dd8CExamination time hh:mm:ss9CType of examination Alphanumeric stringD10COther examinations
24、performed Alphanumeric stringD11 Operator Name Alphanumeric string12COperator identification code Alphanumeric string13CASTM, ISO, or other applicable standard specification Alphanumeric string14 Date of applicable standard yyyy/mm/dd15CAcceptance criteria Alphanumeric string16CSystem of units Alpha
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME14542002STANDARDGUIDEFORDATAFIELDSFORCOMPUTERIZEDTRANSFEROFDIGITALULTRASONICTESTINGDATA 数字 超声波 测试数据

链接地址:http://www.mydoc123.com/p-528717.html