ASTM E1475-2002 Standard Guide for Data Fields for Computerized Transfer of Digital Radiological Test Data《数字放射性测试数据的计算机化传输数据组的标准指南》.pdf
《ASTM E1475-2002 Standard Guide for Data Fields for Computerized Transfer of Digital Radiological Test Data《数字放射性测试数据的计算机化传输数据组的标准指南》.pdf》由会员分享,可在线阅读,更多相关《ASTM E1475-2002 Standard Guide for Data Fields for Computerized Transfer of Digital Radiological Test Data《数字放射性测试数据的计算机化传输数据组的标准指南》.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E 1475 02Standard Guide forData Fields for Computerized Transfer of DigitalRadiological Examination Data1This standard is issued under the fixed designation E 1475; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the y
2、ear of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This guide provides a listing and description of the fieldsthat are recommended for inclusion in a digital rad
3、iologicalexamination data base to facilitate the transfer of such data.This guide sets guidelines for the format of data fields forcomputerized transfer of digital image files obtained fromradiographic, radioscopic, computed radiographic, or otherradiological examination systems. The field listing i
4、ncludesthose fields regarded as necessary for inclusion in the database: (1) regardless of the radiological examination method (asindicated by Footnote C in Table 1), (2) for radioscopicexamination (as indicated by Footnote E in Table 1), and (3) forradiographic examination (as indicated by Footnote
5、 D in Table1). In addition, other optional fields are listed as a reminder ofthe types of information that may be useful for additionalunderstanding of the data or applicable to a limited number ofapplications.1.2 It is recognized that organizations may have in place aninternal format for the storag
6、e and retrieval of radiologicalexamination data. This guide should not impede the use of suchformats since it is probable that the necessary fields are alreadyincluded in such internal data bases, or that the few additionscan easily be made. The numerical listing and its orderindicated in this guide
7、 is only for convenience; the specificnumbers and their order carry no inherent significance and arenot part of the data file.1.3 The types of radiological examination systems thatappear useful in relation to this guide include radioscopicsystems as described in Guide E 1000, Practices E 1255,E 1411
8、 and E 2033, and radiographic systems as described inGuide E94and Practices E 748 and E 1742. Many of the termsused are defined in Terminology E 1316.1.4 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this
9、standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:E94 Guide for Radiographic Examination2E 748 Practices for Thermal Neutron Radiography of Ma-terials2E 1000 Guide for Radio
10、scopy2E 1255 Practice for Radioscopy2E 1316 Terminology for Nondestructive Examinations2E 1411 Practice for Qualification of Radioscopic Systems2E 1416 Test Method for Radioscopic Examination of Weld-ments2E 1742 Practice for Radiographic Examination2E 2033 Practice for Computed Radiology (Photostim
11、ulableLuminescence Method)23. Significance and Use3.1 The primary use of this guide is to provide a standard-ized approach for the data file to be used for the transfer ofdigital radiological data from one user to another where the twousers are working with dissimilar systems. This guide de-scribes
12、the contents, both required and optional for an inter-mediate data file that can be created from the native format ofthe radiological system on which the data was collected andthat can be converted into the native format of the receivingradiological data analysis system. The development of transla-t
13、or software to accomplish these data format conversions isbeing addressed under a separate effort; this will includespecific items needed for the data transfer, for example,language used, memory requirements, and intermediate speci-fication. This guide will also be useful in the archival storageand
14、retrieval of radiological data as either a data formatspecifier or as a guide to the data elements which should beincluded in the archival file.1This guide is under the jurisdiction of ASTM Committee E07 on Nondestruc-tive Testing and is the direct responsibility of Subcommittee E07.11 on DigitalIma
15、ging and Communication in Nondestructive Evaluation (DICONDE).Current edition approved July 10, 2002. Published September 2002. Originallypublished as E 1475 92. Last previous edition E 1475 97.2Annual Book of ASTM Standards, Vol 03.03.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C70
16、0, West Conshohocken, PA 19428-2959, United States.TABLE 1 Field ListingField NumberAField Name and Description Category Sets, Values and UnitsBHeader Information:1C,DIntermediate file name Alphanumeric string2C,DFormat revision code Alphanumeric string3C,DFormat revision date yy/mm/dd4C,DSource fil
17、e name Alphanumeric string5 Examination file description notes Alphanumeric string6C,DExamining company/location Alphanumeric string7C,DExamination date yy/mm/dd8 Examination time hh/mm/ss9C,DType of examination Alphanumeric string10 Other examinations performed Alphanumeric string11C,DOperator name
18、 Alphanumeric string12C,DOperator identification code Alphanumeric string13C,DASTM, ISO or other applicable standard specification Alphanumeric string14 Date of applicable standard yy/mm/dd15C,DAcceptance criteria Alphanumeric string16 Notes Alphanumeric stringExamination System Description:17 Exami
19、nation system manufacturer(s) Alphanumeric string18 Examination system model Alphanumeric string19 Examination system serial number Alphanumeric stringSource Section:20C,DRadiologic source manufacturer Alphanumeric string21C,DRadiological source model Alphanumeric string22 General source description
20、 Alphanumeric string23 Last calibration date Alphanumeric string24 Notes on source section Alphanumeric stringImage Receptor Section:25C,DReceptor type Alphanumeric string26C,DConvertor type Alphanumeric string27 Receptor manufacturer Alphanumeric string28 Receptor model number Alphanumeric string29
21、C,DNotes on receptor section Alphanumeric stringExposure Section:30C,DPeak radiation energy used, or kV31C,DIsotope source (use either 30 or 31) Alphanumeric string32 Tube current mA33 Radiation dosage rate mR/min34 Radiation exposure time min35CSource-detector distance (SDD) m36CSource-object dista
22、nce (SOD) m37CImage magnification of source side of examination object %38DNotes on exposure section Alphanumeric stringProcessing Section (Film/Paper):39EProcess description Automated or manual40EProcess method Wet or dry41 Processor type Alphanumeric string42 Processor model number Alphanumeric st
23、ring43 Notes on processor section Alphanumeric stringImage Processing Description:44C,DImage processing used for image data Alphanumeric string45 Image processor hardware manufacturer Alphanumeric string46 Image processor hardware model Alphanumeric string47 Image processor software source Alphanume
24、ric string48 Image processor software version Alphanumeric string49DPixel resolution Pixels per cm50 Notes on image processor Alphanumeric stringExamination Sample or Part Description:51CSample or part name Alphanumeric string52 Sample or part name description Alphanumeric string53CSample or part id
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME14752002STANDARDGUIDEFORDATAFIELDSFORCOMPUTERIZEDTRANSFEROFDIGITALRADIOLOGICALTESTDATA 数字 放射性 测试数据

链接地址:http://www.mydoc123.com/p-528755.html