《ASTM E1165-2012(2017) Standard Test Method for Measurement of Focal Spots of Industrial X-Ray Tubes by Pinhole Imaging《使用针孔图像测量工业X射线管焦点测试方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM E1165-2012(2017) Standard Test Method for Measurement of Focal Spots of Industrial X-Ray Tubes by Pinhole Imaging《使用针孔图像测量工业X射线管焦点测试方法》.pdf(13页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E1165 12 (Reapproved 2017)Standard Test Method forMeasurement of Focal Spots of Industrial X-Ray Tubes byPinhole Imaging1This standard is issued under the fixed designation E1165; the number immediately following the designation indicates the year oforiginal adoption or, in the case of
2、revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 The image quality and the resolution of X-ray imageshighly depend on the characteristics of the
3、focal spot. Theimaging qualities of the focal spot are based on its twodimensional intensity distribution as seen from the detectorplane.1.2 This test method provides instructions for determiningthe effective size (dimensions) of standard and mini focal spotsof industrial x-ray tubes. This determina
4、tion is based on themeasurement of an image of a focal spot that has beenradiographically recorded with a “pinhole” technique.1.3 This standard specifies a method for the measurement offocal spot dimensions from 50 m up to several mm of X-raysources up to 1000 kV tube voltage. Smaller focal spots sh
5、ouldbe measured using EN 12543-5 using the projection of an edge.1.4 This test method may also be used to determine thepresence or extent of focal spot damage or deterioration thatmay have occurred due to tube age, tube overloading, and thelike. This would entail the production of a focal spot radio
6、-graph (with the pinhole method) and an evaluation of theresultant image for pitting, cracking, and the like.1.5 Values stated in SI units are to be regarded as thestandard.1.6 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibili
7、ty of the user of this standard to establish appro-priate safety, health, and environmental practices and deter-mine the applicability of regulatory limitations prior to use.1.7 This international standard was developed in accor-dance with internationally recognized principles on standard-ization es
8、tablished in the Decision on Principles for theDevelopment of International Standards, Guides and Recom-mendations issued by the World Trade Organization TechnicalBarriers to Trade (TBT) Committee.2. Referenced Documents2.1 ASTM Standards:2E1000 Guide for RadioscopyE1255 Practice for RadioscopyE2002
9、 Practice for Determining Total Image Unsharpnessand Basic Spatial Resolution in Radiography and Radios-copyE2033 Practice for Computed Radiology (PhotostimulableLuminescence Method)E2698 Practice for Radiological Examination Using DigitalDetector Arrays2.2 European Standards:3EN 12543-2 Non-destruc
10、tive testingCharacteristics of fo-cal spots in industrial X-ray systems for use in non-destructive testingPart 2: Pinhole camera radiographicmethodEN 12543-5 Non-destructive testingCharacteristics of fo-cal spots in industrial X-ray systems for use in non-destructive testingPart 5: Measurement of th
11、e effectivefocal spot size of mini and micro focus X-ray tubes2.3 Papers:Klaus Bavendiek, Uwe Heike, Uwe Zscherpel, Uwe EwertAnd Adrian Riedo, “New measurement methods of focalspot size and shape of X-ray tubes in digital radiologicalapplications in comparison to current standards,” WC-NDT 2012, Dur
12、ban, South Africa3. Terminology3.1 Definitions of Terms Specific to This Standard:3.1.1 actual focal spotthe X-ray producing area of thetarget as viewed from a position perpendicular to the targetsurface (see Fig. 1).3.1.2 effective focal spotthe X-ray producing area of thetarget as viewed from a po
13、sition perpendicular to the tube axisin the center of the X-ray beam (see Fig. 1).1This test method is under the jurisdiction of ASTM Committee E07 onNondestructive Testing and is the direct responsibility of Subcommittee E07.01 onRadiology (X and Gamma) Method.Current edition approved Nov. 1, 2017.
14、 Published December 2017. Originallyapproved in 1987. Last previous edition approved in 2012 as E1165 12. DOI:10.1520/E1165-12R17.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume informat
15、ion, refer to the standards Document Summary page onthe ASTM website.3Available from European Committee for Standardization (CEN), AvenueMarnix 17, B-1000, Brussels, Belgium, http:/www.cen.eu.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United S
16、tatesThis international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for theDevelopment of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to
17、Trade (TBT) Committee.13.1.3 effective size of focal spotfocal spot size measured inaccordance with this standard.4. Summary of Test Method4.1 This method is based on a projection image of the focalspot using a pinhole camera. This image shows the intensitydistribution of the focal spot. From this i
18、mage the effective sizeof the focal spot is computed. A double integration of a profileacross the pinhole image transforms the pinhole image into anedge profile. The X- and Y-dimension of the edge unsharpnessis used for calculation of the size of the focal spot. This methodprovides similar results a
19、s the method described in EN 12543-5using an edge target instead of a pinhole camera. The measuredeffective spot sizes correspond to the geometrical imageunsharpness values at given magnifications as measured withthe ASTM E2002 duplex wire gauge in practical images usingequation:uG5 v 2 1! (1)with g
20、eometrical unsharpness uG, focal spot size andmagnification v (seeASTM E1000 for details of this equation).For a full description see Reference 2.3.4.2 Additionally, a simplified test method is described in theannex A for users of X-ray tubes who may not intend to use apinhole camera. This alternati
21、ve method is based on the edgemethod in accordance with EN 12543-5 using a plate hole IQIas described in ASTM E1025 or E1742 instead of a pinholecamera.5. Significance and Use5.1 One of the factors affecting the quality of radiologicimages is the geometric unsharpness. The degree of geometricunsharp
22、ness is dependent on the focal spot size of the radiationsource, the distance between the source and the object to beradiographed, and the distance between the object to beradiographed and the detector (imaging plate, Digital DetectorArray (DDA) or film). This test method allows the user todetermine
23、 the effective focal size of the X-ray source. Thisresult may then be used to establish source to object and objectto detector distances appropriate for maintaining the desireddegree of geometric unsharpness and/or maximum magnifica-tion for a given radiographic imaging application. SomeASTMstandard
24、s require this value for calculation of a requiredmagnification, for example, E1255, E2033, and E2698.6. Apparatus6.1 Pinhole DiaphragmThe pinhole diaphragm shall con-form to the design and material requirements of Table 1 andFig. 3.6.2 CameraThe pinhole camera assembly consists of thepinhole diaphr
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME116520122017STANDARDTESTMETHODFORMEASUREMENTOFFOCALSPOTSOFINDUSTRIALXRAYTUBESBYPINHOLEIMAGING 使用

链接地址:http://www.mydoc123.com/p-528062.html