ASTM E1164-2012(2017)e1 Standard Practice for Obtaining Spectrometric Data for Object-Color Evaluation《用光谱测得数据评定物体颜色的标准实施规程》.pdf
《ASTM E1164-2012(2017)e1 Standard Practice for Obtaining Spectrometric Data for Object-Color Evaluation《用光谱测得数据评定物体颜色的标准实施规程》.pdf》由会员分享,可在线阅读,更多相关《ASTM E1164-2012(2017)e1 Standard Practice for Obtaining Spectrometric Data for Object-Color Evaluation《用光谱测得数据评定物体颜色的标准实施规程》.pdf(9页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E1164 12 (Reapproved 2017)1Standard Practice forObtaining Spectrometric Data for Object-Color Evaluation1This standard is issued under the fixed designation E1164; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the ye
2、ar of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1NOTEEditorial corrections were made throughout in May 2017.INTRODUCTIONThe fundamental procedure for evaluating the color o
3、f a reflecting or transmitting object is to obtainspectrometric data for specified illuminating and viewing conditions, and from these data to computetristimulus values based on a CIE (International Commission on Illumination) standard observer anda CIE standard illuminant. The considerations involv
4、ed and the procedures used to obtain precisespectrometric data are contained in this practice. The values and procedures for computing CIEtristimulus values from spectrometric data are contained in Practice E308. Considerations regardingthe selection of appropriate illuminating and viewing geometrie
5、s are contained in Guide E179.1. Scope1.1 This practice covers the instrumental measurementrequirements, calibration procedures, and material standardsneeded to obtain precise spectral data for computing the colorsof objects.1.2 This practice lists the parameters that must be specifiedwhen spectrome
6、tric measurements are required in specificmethods, practices, or specifications.1.3 Most sections of this practice apply to bothspectrometers, which can produce spectral data as output, andspectrocolorimeters, which are similar in principle but canproduce only colorimetric data as output. Exceptions
7、 to thisapplicability are noted.1.4 This practice is limited in scope to spectrometers andspectrometric colorimeters that employ only a single mono-chromator. This practice is general as to the materials to becharacterized for color.1.5 The values stated in SI units are to be regarded asstandard. No
8、 other units of measurement are included in thisstandard.1.6 This standard does not purport to address the safetyconcerns, if any, associated with its use. It is the responsibilityof the user of this standard to establish appropriate safety andhealth practices and determine the applicability of regu
9、latorylimitations prior to use.1.7 This international standard was developed in accor-dance with internationally recognized principles on standard-ization established in the Decision on Principles for theDevelopment of International Standards, Guides and Recom-mendations issued by the World Trade Or
10、ganization TechnicalBarriers to Trade (TBT) Committee.2. Referenced Documents2.1 ASTM Standards:2D1003 Test Method for Haze and Luminous Transmittanceof Transparent PlasticsE179 Guide for Selection of Geometric Conditions forMeasurement of Reflection and Transmission Propertiesof MaterialsE259 Pract
11、ice for Preparation of Pressed Powder WhiteReflectance Factor Transfer Standards for Hemisphericaland Bi-Directional GeometriesE275 Practice for Describing and Measuring Performance ofUltraviolet and Visible SpectrophotometersE284 Terminology of AppearanceE308 Practice for Computing the Colors of Ob
12、jects by Usingthe CIE SystemE387 Test Method for Estimating Stray Radiant Power Ratioof Dispersive Spectrophotometers by the Opaque FilterMethodE805 Practice for Identification of Instrumental Methods ofColor or Color-Difference Measurement of Materials1This practice is under the jurisdiction of AST
13、M Committee E12 on Color andAppearance and is the direct responsibility of Subcommittee E12.02 on Spectro-photometry and Colorimetry.Current edition approved May 1, 2017. Published May 2017. Originallyapproved in 1987. Last previous edition approved in 2012 as E1164 121. DOI:10.1520/E1164-12R17E01.2
14、For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C7
15、00, West Conshohocken, PA 19428-2959. United StatesThis international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for theDevelopment of International Standards, Guides and Recommendations issued by the W
16、orld Trade Organization Technical Barriers to Trade (TBT) Committee.1E925 Practice for Monitoring the Calibration of Ultraviolet-Visible Spectrophotometers whose Spectral Bandwidthdoes not Exceed 2 nmE958 Practice for Estimation of the Spectral Bandwidth ofUltraviolet-Visible SpectrophotometersE991
17、Practice for Color Measurement of Fluorescent Speci-mens Using the One-Monochromator MethodE1767 Practice for Specifying the Geometries of Observa-tion and Measurement to Characterize the Appearance ofMaterialsE2153 Practice for Obtaining Bispectral Photometric Datafor Evaluation of Fluorescent Colo
18、rE2194 Test Method for Multiangle Color Measurement ofMetal Flake Pigmented Materials2.2 NIST Publications:LC-1017 Standards for Checking the Calibration of Spec-trophotometers3TN-594-12 Optical Radiation Measurements: The Translu-cent Blurring EffectMethod of Evaluation and Estima-tion3SP-260-66 Di
19、dymium Glass Filters for Calibrating theWavelength Scale of SpectrophotometersSRM 2009,2010, 2013, and 20143SP-692 Transmittance MAP Service32.3 CIE Publications:CIE No. 15 Colorimetry4CIE No. 38 Radiometric and Photometric Characteristics ofMaterials and Their Measurement4CIE No. 46 Review of Publi
20、cations on Properties andReflection Values of Material Reflection Standards4CIE No. 51 Method for Assessing the Quality of DaylightSimulators for Colorimetry4CIE No. 130 Practical Applications of Reflectance andTransmittance Measurements42.4 ISO Publications:ISO 2469 Paper, Board and Pulps Measureme
21、nt ofDiffuse Reflectance Factor52.5 ISCC Publications:Technical Report 2003-1 Guide to Material Standards andTheir Use in Color Measurement63. Terminology3.1 DefinitionsThe definitions contained in TerminologyE284 are applicable to this practice.3.2 Definitions of Terms Specific to This Standard:3.2
22、.1 influx, nthe cone of light rays incident upon thespecimen from the illuminator in a color measuring instrument(see Practice E1767).3.2.2 efflux, nthe cone of light rays reflected or transmittedby a specimen and collected by the receiver in a colormeasuring instrument (see Practice E1767).3.2.3 re
23、gular transmittance factor, Tr,nthe ratio of theflux transmitted by a specimen and evaluated by a receiver tothe flux passing through the same optical system and evaluatedby the receiver when the specimen is removed from the system.3.2.3.1 DiscussionIn some cases, this quantity is practi-cally ident
24、ical to the transmittance, but it may differ consider-ably. It exceeds unity if the system is such that the specimencauses more light to reach the receiver than would in itsabsence.4. Summary of Practice4.1 Procedures are given for selecting the types and oper-ating parameters of spectrometers used
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME116420122017E1STANDARDPRACTICEFOROBTAININGSPECTROMETRICDATAFOROBJECTCOLOREVALUATION 用光 数据 评定 物体

链接地址:http://www.mydoc123.com/p-528057.html