《ASTM E1158-2014 Standard Guide for Material Selection and Fabrication of Reference Blocks for the Pulsed Longitudinal Wave Ultrasonic Testing of Metal and Metal Alloy Production Ma.pdf》由会员分享,可在线阅读,更多相关《ASTM E1158-2014 Standard Guide for Material Selection and Fabrication of Reference Blocks for the Pulsed Longitudinal Wave Ultrasonic Testing of Metal and Metal Alloy Production Ma.pdf(7页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E1158 09E1158 14Standard Guide forMaterial Selection and Fabrication of Reference Blocks forthe Pulsed Longitudinal Wave Ultrasonic Testing of Metaland Metal Alloy Production Material1This standard is issued under the fixed designation E1158; the number immediately following the designa
2、tion indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope Scope*1.1 This guide covers general
3、procedures for the material selection and fabrication of reference blocks made of metal or metalalloys and intended to be used for the examination of the same or similar production materials by pulsed longitudinal ultrasonicwaves applied perpendicular to the beam entry surface. Primary emphasis is o
4、n solid materials but some of the techniquesdescribed may be used for midwall examination of pipes and tubes of heavy wall thickness. Near-surface resolution in any materialdepends upon the characteristics of the instrument and search unit employed.1.2 This guide covers the fabrication of reference
5、blocks for use with either the immersion or the contact method of ultrasonicexamination.1.3 Reference blocks fabricated in accordance with this guide can be used to determine proper ultrasonic system operation.Area-amplitude and distance-amplitude curves can also be determined with these reference b
6、locks.1.4 This guide does not specify reference reflector sizes or product rejection limits. It does describe typical industry fabricationpractices and commonly applied tolerances where they lend clarity to the guide. In all cases of conflict between this guide andcustomer specifications, the custom
7、er specification shall prevail.1.5 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematicalconversions to SI units that are provided for information only and are not considered standard.1.6 This standard does not purport to address the sa
8、fety concerns, if any, associated with its use. It is the responsibility of theuser of this standard to establish appropriate safety and health practices and to determine the applicability of regulatorylimitations prior to use.2. Referenced Documents2.1 ASTM Standards:2E127 Practice for Fabricating
9、and Checking Aluminum Alloy Ultrasonic Standard Reference Blocks3E428 Practice for Fabrication and Control of Metal, Other than Aluminum, Reference Blocks Used in Ultrasonic TestingE1316 Terminology for Nondestructive Examinations3. Terminology3.1 DefinitionsFor definitions of terms used in this gui
10、de, see Terminology E1316.4. Summary of Guide4.1 This guide describes a method of selecting suitable reference block material from current or previous production and thesubsequent fabrication and checking of the resulting ultrasonic reference blocks.1 This guide is under the jurisdiction of ASTM Com
11、mittee E07 on Nondestructive Testing and is the direct responsibility of Subcommittee E07.06 on Ultrasonic Method.Current edition approved June 1, 2009June 1, 2014. Published July 2009July 2014. Originally approved in 1990. Last previous edition approved in 20042009 asE1158 - 04.E1158 - 09. DOI: 10.
12、1520/E1158-09.10.1520/E1158-14.2 For referencedASTM standards, visit theASTM website, www.astm.org, or contactASTM Customer Service at serviceastm.org. For Annual Book of ASTM Standardsvolume information, refer to the standards Document Summary page on the ASTM website.3 The reference blocks in Prac
13、tice E127 are used to check the performance of ultrasonic examination equipment and for standardization and control of ultrasonicexaminations of aluminum alloy products. The ultrasonic response of the blocks in Practice E127 is evaluated against a standard target. The blocks described in this standa
14、rdare used for the examination of production material and may be used to establish accept-reject criteria.This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Becauseit may not be tech
15、nically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current versionof the standard as published by ASTM is to be considered the official document.*A Summary of Changes section appears at the end of this
16、 standardCopyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States15. Significance and Use5.1 This guide is intended to illustrate the fabrication of ultrasonic reference blocks that are representative of the productionmaterial to be examined.
17、Care in material selection and fabrication can result in the manufacture of reference blocks that areultrasonically similar to the production material thus eliminating the reference block as an examination variable.6. Material Selection6.1 It is good practice to use a sample removed from the product
18、ion lot of material as the reference block material. When thisis not possible the following guidelines should be followed.6.2 The reference block material should be of the same general shape and dimensions, surface finish, chemical composition, andmicrostructure as the production material to be exam
19、ined.6.3 To ensure that the material chosen is suitable for use as reference block material and is free of potentially interferingreflectors, ultrasonically examine the reference block material at the anticipated frequency and at a sensitivity that produces anacoustic noise level of 20 % screen heig
20、ht. The entire block should be scanned from the surface which will be used forstandardization.Any discrete indication that exceeds 40 % screen height should be cause to remove the material from considerationas an ultrasonic reference block.6.4 Reference block material that meets the guidelines of 6.
21、3 should then be examined at a sensitivity that produces multiplereflections from the back surface (between 3 and 5 reflections in most metals and metal alloys). The production material shouldbe examined at the same sensitivity level to determine that the same number of back reflections are obtained
22、. This procedure mayhave to be repeated several times and an average number of back reflections determined in the case of some materials (see Note1).NOTE 1In some highly attenuative materials more than one or two back reflections may not be attainable. In these cases, selection of the referenceblock
23、 material may be based on similar acoustic noise levels from both the production material and that chosen for a reference block.7. Reference Block Configuration7.1 There are many different types of reference blocks used in industry depending upon the size and shape of the material tobe examined. Som
24、e of the more common flat bottom hole (FBH) types are described in 7.2 through 7.7, and shown in Figs. 1-7.An alternate method for fabricating FBHs is described in the annex.7.2 Fig. 1 shows the typical reference standards used for ultrasonic examination when the product to be examined consists ofla
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME11582014STANDARDGUIDEFORMATERIALSELECTIONANDFABRICATIONOFREFERENCEBLOCKSFORTHEPULSEDLONGITUDINALWAVEULTRASONICTESTINGOFMETALANDMETALALLOYPRODUCTIONMAPDF

链接地址:http://www.mydoc123.com/p-528039.html